5-TON ELECTRIC LOG SPLITTER

 

Changing the Hydraulic Fluid 

Tools and Supplies Needed 

 

6mm Allen Wrench 

 

Clean Rags 

 

Small Funnel 

 

Hydraulic Fluid 

 

Approved Container (1 gallon or more capacity) 

Replace the Hydraulic Fluid in the Electric Log Splitter after every 150 hours of 
use.  Take the following steps to replace the Fluid.

 

1.

 

Make sure the Air Bleed Screw is screwed down tight. 

2.

 

Tip the machine up vertical on the Wheels (you may need to have someone 
support the splitter to prevent tipping over).  Clean the area around the 
Hydraulic Fluid Fill/Drain Port (Figure 13) and then, using a 6mm Allen 
Wrench, unscrew and remove the Dipstick located in the Hydraulic Fluid 
Fill/Drain Port.

 

3.

 

Tip the Splitter down onto the Legs as you drain the Fluid into an approved 
Container (1 gallon or more capacity) and continue tipping the machine until 
the Tank is empty (Figure 14). 

4.

 

Tip the Splitter up vertical onto the Wheels again and insert a Small Funnel 
into the Dipstick opening. 

5.

 

Refill the Tank with 3.4 quarts of fresh Hydraulic Fluid. 

6.

 

Clean the Dipstick with a Rag, insert the Dipstick (do not screw the Dipstick 
down when checking), remove and check the level; it should be between the 
two marks on the Dipstick.  If the fluid is too high, simply pour out a little at 
a time into a suitable container by tilting the Electric Log Splitter.  If the fluid 
is too low, insert a small Funnel and add Hydraulic Fluid (See 
“Specifications” in Chapter 2 for Fluid type) a little at a time, until the level 
falls between the two marks on the Dipstick. 

7.

 

Clean the Dipstick and the Copper Washer thoroughly and reinstall the Dipstick, being careful not to damage the threads of 
the aluminum Hydraulic Fluid Cylinder End Cover. 

8.

 

Lower the machine to the ground, loosen the Air Bleed Screw three or four turns counterclockwise and cycle the Ram back and 
forth 3 or 4 times to purge any air from the hydraulic system (See Operating The DR 5-TON ELECTRIC LOG SPLITTER in 
Chapter 3). 

9.

 

Periodically check fluid level to ensure it is between the 2 grooves around the dipstick. If the level is below the lower limit, fill 
until level is correct. 

Sharpening the Wedge 

Tools needed: 

 

Fine-Toothed Flat File 

1.

 

Before each splitting session, check the sharpness of the Wedge.  As required, remove any burrs or flat spots on the Wedge 
using a fine-toothed flat file. 

Hydraulic Fluid 
Drain Port 

Drain Pan 

Figure 14 

Hydraulic Fluid 
Drain/Dipstick 

Figure 13 

Air Bleed 
Screw 

Содержание PILOT 5TE

Страница 1: ...structions before operating the DR 5 TON ELECTRIC LOG SPLITTER Serial No Order No DR Power Equipment Toll free phone 1 800 DR OWNER 376 9637 Website www DRpower com DR 5 TON ELECTRIC LOG SPLITTER SAFE...

Страница 2: ...n your order history and is located on your packing slip For your convenience and ready reference enter the Serial Number and Order Number in the space provided on the front cover of this manual Addit...

Страница 3: ...NER 376 9637 and one of our Technical Support Representatives will be happy to help you Chapter 1 General Safety Rules Labels Your DR 5 TON ELECTRIC LOG SPLITTER carries prominent labels as reminders...

Страница 4: ...lic fluid can remain pressurized while the motor is off due to the return spring force on the ram Always follow these precautions Always release residual energy from pressurized hydraulic fluid and al...

Страница 5: ...in melting of the insulation or even create a fire Always keep the electrical cord and or extension cord away from excessive heat oil and sharp objects Safety for Children and Pets Safety with Electr...

Страница 6: ...as squarely as possible Never split more than one log at a time unless you fully extended the ram and you need a second log to complete the split of the first log Never put anything between the log gu...

Страница 7: ...these procedures If you have any questions at all please feel free to contact us at www DRpower com DR 5 TON ELECTRIC LOG SPLITTER Controls and Features Splitting Wedge Log Ram Rubber Wheels Oil Pump...

Страница 8: ...ifficult to split logs with regular fibers even if its diameter exceeds the 10 max indicated above Log Splitter is shipped with Hydraulic Fluid already added Assembly Tools Needed Pliers 16mm Wrench 1...

Страница 9: ...Prior to using the Electric Log Splitter open the Air Bleed Screw by turning the Thumbscrew counter clockwise three to four times Figure 4 Leave the Air Bleed Screw open in this position while using...

Страница 10: ...ings listed in Chapter 1 General Safety Rules before operating this DR Dual action electric log splitter If any doubt or question arises about the correct or safe method of performing anything found i...

Страница 11: ...dle Figure 9 Figure 8 Figure 7 Do not place your hands on the ends of the log when loading the Log Splitter This is a very UNSAFE method and could result in injury to your hands Figure 7 Do not reach...

Страница 12: ...o of the Control Lever and the Ram will return to the retracted position If the log does not split immediately do not continue the forward thrust of the ram for more than five seconds This can damage...

Страница 13: ...eed to have someone support the Electric Log Splitter to prevent tipping over Clean the area around the Hydraulic Fluid Fill Drain Port Figure 12 and then using a 6mm Allen Wrench unscrew and remove t...

Страница 14: ...when checking remove and check the level it should be between the two marks on the Dipstick If the fluid is too high simply pour out a little at a time into a suitable container by tilting the Electr...

Страница 15: ...um diameter of 10 for the DR 5 TON ELECTRIC LOG SPLITTER The Splitting Wedge has burrs or nicks and needs sharpening There may be a hydraulic fluid leak Locate the leak using a piece of cardboard unde...

Страница 16: ...39 A0000938026 Plastic Sleeve 40 A0000938024 Nut M6 41 A0000944999 Set Screw Internal Hex Head M6 X 20 42 A0000938023 Hex Nut 43 A0000938022 Bushing Short Shaft 44 A0000937683 Washer Lock 10 Ref Part...

Страница 17: ...CONTACT US AT www DRpower com 17 Schematic DR 5 TON ELECTRIC LOG SPLITTER...

Страница 18: ...esponsible for the performance of the required maintenance as defined by the manufacturer s owner s manuals The warranty holder is responsible for replacement of normally wearing parts This warranty d...

Страница 19: ...CONTACT US AT www DRpower com 19 Notes...

Страница 20: ...the DR 5 TON ELECTRIC LOG SPLITTER to remove any moisture wood chips and dirt that may have accumulated on the Log Guides and Operating Handle Apply a thin coating of oil or 2 Lithium Grease to the l...

Отзывы: