background image

Содержание ICHECK Connect-118

Страница 1: ... renowned global leader in health care products DrTrust ensures that our technically efficient team works dynamically and tirelessly to provide the best of the medical devices to our clients The products that we haveto offer are suitablydesignedfor useat homes laboratoriesandhospitals Our ground breaking solutions allow you to monitor your health in the easiest ways possible In today s era when al...

Страница 2: ...arise 2 3 Whathealthproblemsareassociatedwithhighbloodpressure 3 VARIOUS COMPONENTS OF THE BLOOD PRESSURE MONITOR 4 PUTTING THE BLOOD PRESSURE MONITOR INTO OPERATION 22 11 SAFETY CARE ANDDISPOSAL 22 12 REFERENCETO STANDARDS 23 13 REMARK 8 24 14 TECHNICAL SPECIFICATIONS 10 25 15 MANUFACTURER SDECLARATION 4 1 InsertingTheBatteries 4 2 ReadingTheSet Date 4 3 User Selection AndSettingTheTime Date 5 CA...

Страница 3: ...our scale Better accuracy is ensured in case of repeated measurements Also allowsfor immediaterepeat measurement for comparison withleastdifference 1 2 Key Features of Dr Trust iCheck Connect 118 with MDI Thedeviceisintendedfor self useat home Fullyautomatic digitaldevicewithMDI technology Comes witharmmovement detector andcuff Okindicator 1 INTRODUCTION Dr Trust The arm cuff is inflated around th...

Страница 4: ...ssure monitor is recommended In this way you can detect possible changes in your values early and react appropriately If you are undergoing medical treatment to control your blood pressure please keep a record of the level of your blood pressure by carrying out regular self measurements at specific timesoftheday Showthesevaluestoyourdoctor Donot let thecuff pressureyouonthearm whichis onthesideofa...

Страница 5: ...n 110 Urgently seek medical ON OFF Button advice Setting Button Bluetooth Button Further Information If your values are mostly standard under resting conditions but exceptionally high under conditions of physical or psychological stress it is possible that you are sufferingfrom so called labilehypertensions Correctly measured diastolic blood pressure values above 120mmHg require immediatemedicaltr...

Страница 6: ...ime Date This blood pressure monitor incorporates an integrated clock with date display This hastheadvantage thatat eachmeasurement procedure not onlytheblood pressure www drtrustusa com 1 Firstly press the TIME button for at least 3 seconds then user icon will blink Then press TIME button again the display now indicates the set year during which the four charactersblink Thecorrectyear can beenter...

Страница 7: ...easurement arm duringthemeasurement Use acushionfor support if necessary The performance of the BP Monitor can be affected by extremes of temperature humidityandaltitude Avoidcompression or restrictionoftheconnectiontubing A loosecuffcausesfalsemeasurementsvalues Withrepeatedmeasurements bloodaccumulatesintherespectivearm whichcan lead to falseresults Dr Trust 1 Dr Trust 5 2 Fitting the cuff Inser...

Страница 8: ...esults are displayed until you switch the device off If no button is pressed for 3 minutes the device switches automatically off to save the batteries 5 4 Discontinuing a Measurement If it is necessary to interrupt a blood pressure measurement for any reason e g the patient feels unwell the ON OFF power button can be pressed at any time The device thenimmediatelylowersthecuff pressureautomatically...

Страница 9: ...tically Overwritten with new ones When memory is full the display shown 1 second as follows to remind you memory full Ld J C n H UK r 5 8 Memory Cancellation Of All Measurements Before you delete all readings stored in the memory make sure you will not need refer to the readings later Keeping a written record is prudent and may provide additionalinformation for your doctor s visit In order to dele...

Страница 10: ...n measuring interface click Start the device begins to measure blood pressure automatically image 6 please do not move and speak 6 Complete the measurement the application displays the measurement results automatically image 7 The user can choose to save the data to the phone the measurement results will also be stored in the device 7 If the user wants to look up the previous measurement history t...

Страница 11: ...duces a different value although the instrument functions normally and the values displayed are normal 1 Please read the following information and the points listed under Common sources of error Repeat the measurement Please Note Blood pressure fluctuates continually so successive measurements will show some variability Observe the storage and operating conditions described in the Technical specif...

Страница 12: ...the device and the components in a clean safe location Do not disassemble or attempt to repair the unit or components as it will void the user warranty 0 3 IEC60601 1 2 2014 EN60601 1 2 2015 IEC EN60601 1 11 2015 IEC80601 2 30 2009 A1 2013 EN80601 2 30 2010 A1 2015 The stipulations of the EU Guidelines 93 42 EEC for Medical Products Class lla have been fulfilled 13 REMARK Some electrical and elect...

Страница 13: ...pump Memory function 2 x 120 memories for 2 users SYS DIA Pulse Decompression Constant exhaust valve system RF emissions CISPR 11 Class B Dr Trust iCheckConnect 118 withMDIis suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Power source 4 size AAA a...

Страница 14: ... 2Hz 1 kV differential Not applicable Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 IEC 61000 4 6 3 Vrms mode 2 kV common Radiated RF 3 Vrms 80 MHz mode IEC 61000 4 3 to 2 5 GHz 80 AM 2Hz 3 V m Voltage dips short interruptions and voltage variations on power supply input Not applicable Mains power quality should be that of a typical commerci...

Страница 15: ...ivate Limited 103 104 Orbit Plaza New Prabhadevi Marg Prabhadevi Mumbai Maharashtra 400025 Separation distance according to frequency of transmitter m Rated maximum output power of transmitter Call On USA 1 212 634 4563 India Toll free 18002709565 150 kHz to 80 MHz d 1 2xp 1 2 80 MHz to 800 MHz d 1 2xp 1 2 800 MHz to 2 5 GHz d 2 3xp 1 2 W 0 01 0 12 0 12 0 23 Website www drtrustusa com Email custom...