background image

16

17

Troubleshooting

Cleaning & Maintenance

The Clear

Air

 Whole Home Air Purifier Fails to Turn On:

1 .  Verify that the POWER PLUG is plugged into an operational wall outlet .
2 .  Ensure that the POWER CORD is fully inserted (leaving less than an 1/8”) into 

the DC POWER ADAPTER and the green light on the DC POWER ADAPTER is 

illuminated .

3 .  Ensure that the DC POWER ADAPTER PLUG is fully seated in the DC POWER 

ADAPTER INLET.

4 .  Verify the POWER BUTTON has been activated on the CONTROL PANEL .
5 .  If the POWER BUTTON on the CONTROL PANEL fails, use the POWER BUTTON on 

the REMOTE CONTROL . If the CONTROL PANEL fails, contact the Mercola .com 

Customer Service team at (847) 252-4355 .

No Noticeable Activated Oxygen (Ozone) is Being Produced in HIGH MODE or AWAY 

MODE: 

1 .  Ensure that the PURIFICATION PLATE is clean. (See “CLEANING” on page 16)
2 .  The PURIFICATION PLATE may not be working because it needs to be replaced. 

Try installing a new PURIFICATION PLATE.

3 .  Check the electrical contact arms which touch the plate to ensure that they are 

making proper contact with the metal mesh on the PURIFICATION PLATE.

4 .  Ensure the electrical contact arms which touch the plate are clean . Clean them 

with a soft cloth and rubbing alcohol .

5 .  Turn the lights off in the room and look through the FRONT GRILLE at the 

PURIFICATION PLATE. When it is operating properly, the PURIFICATION PLATE will 

produce a dim purple glow .

The PURIFICATION PLATE Generates an Electrical Arc, an Arcing Noise or a 

Burning Odor:

This means the PURIFICATION PLATE is damaged and must be replaced. To order a 

replacement, contact the Mercola .com Customer Service team at (847) 252-4355 . 

Your Clear

Air

 Whole Home Air Purifier should be cleaned at least once a month to 

keep it running at peak performance, but may be required more often if its operating 

environment is heavily contaminated .

Cleaning the Clear

Air 

Whole Home Air Purifier (Exterior):

Wipe down the exterior with a damp cloth or use compressed air or a vacuum cleaner 

to remove dust .

Cleaning the FILTER ASSEMBLY:

You may use clean water or compressed air to clean your FILTER ASSEMBLY once 

it has been disassembled (see “DISASSEMBLY” on page 12) . After disassembling 

your Clear

Air 

Whole Home Air Purifier, the three filters (mesh, foam and honeycomb) 

should be removed and cleaned separately . If using water, you must allow the filters 

to completely dry separately before reassembly . When reassembling, the Honeycomb 

Filter goes in first, then the Foam Filter, and finally the thin Mesh Filter. Lastly, 

reattach the rim to the FILTER ASSEMBLY.

Cleaning the IONIZATION NEEDLE:

Using a cotton applicator (Q-tip), apply a small amount of clear alcohol-based cleaner 

(or rubbing alcohol) to the IONIZATION NEEDLE. You may also use compressed air to 

blow off any dust that may accumulate near the IONIZATION NEEDLE.

Cleaning the PCO CELL:

Using a compressed air or a vacuum cleaner, blow and/or vacuum the dust out of 

the PCO CELL. Do not use any liquid to clean the PCO CELL. Do not disassemble the 

PCO CELL.

Cleaning the PURIFICATION PLATE:

Using white vinegar or a solution of equal parts warm water and clear ammonia, 

soak the PURIFICATION PLATE for 8-10 hours but do not exceed 12 hours. Using a 

soft-bristle brush, scrub the wire mesh to remove debris . Rinse thoroughly . Allow 

the PURIFICATION PLATE to dry completely before reinstalling. Use a soft cloth and 

rubbing alcohol to clean the contacts on the interior of the Clear

Air

 Whole Home Air 

Purifier that touch the PURIFICATION PLATE.

Cleaning the Clear

Air 

Whole Home Air Purifier (Interior):

Using a damp cloth, a clear alcohol-based cleaner, compressed air or a vacuum 

cleaner, carefully clean the walls and components inside of the Clear

Air

 Whole Home 

Air Purifier only after completing the disassembly procedures found in DISASSEMBLY 

on pages 12 - 13 .

Resetting the “PERFORM CLEANING” Maintenance Reminder:

To reset the “PERFORM CLEANING” maintenance reminder, press and hold the 

REMINDER RESET BUTTON until the reminder goes away . It will return after 30 days 

of use .

Содержание Whole Home

Страница 1: ...Owner s Manual ...

Страница 2: ... four different technologies Photocatalytic Oxidation PCO Ionization Activated Oxygen and Filtration to purify the air and surfaces throughout your home Follow the instructions provided with your ClearAir Whole Home Air Purifier to assist with easy set up and continued usage instructions After 30 days of continuous use the unit will display the message Perform Cleaning to remind you to perform mai...

Страница 3: ...MODE to exceed the actual square footage of the space being treated Do not use AWAY MODE in occupied spaces Short term exposure to ozone levels exceeding 0 5 ppm can cause temporary adverse reactions The ClearAir Whole Home Air Purifier should be powered off and the POWER CORD should be disconnected when cleaning or servicing your unit The ClearAir Whole Home Air Purifier is not a medical device a...

Страница 4: ... Retaining Nuts PCO Cell Connector Purification Plate POWER SUPPLY Power Cord Power Cord Plug DC Power Adapter DC Power Adapter Plug 1 4 8 6 10 7 11 2 3 5 9 CONTROL PANEL and REMOTE Power Button Sleep Mode Control Fan Speed Control Reminder Reset Button Infrared Receiver Purifier Level Control Away Mode Toggle Normal High Mode Toggle 1 4 6 3 8 2 5 7 1 6 8 2 3 7 1 3 4 5 6 7 8 1 2 3 4 5 7 8 9 10 11 ...

Страница 5: ... into the rear of the unit and then plug the POWER CORD into the wall Make sure the POWER CORD is securely seated in the DC POWER ADAPTER and that the green indicator light on the DC POWER ADAPTER is lit This green light indicates that the unit has been properly connected Diagrams Display Here s how the DISPLAY appears when in each of the modes Maintenance Reminders PERFORM CLEANING Perform Cleani...

Страница 6: ...ing less than the square footage of the area being treated is acceptable and may be desirable in an environment relatively free of pollutants 6 Use your nose to confirm the proper square footage setting If the setting is too low for the area you may notice musty cooking animal or other types of odors If the setting is too high you may notice an oxidation smell which some liken to the smell of chlo...

Страница 7: ...e of FILTER ASSEMBLY to remove the rim and access the separate honeycomb foam and mesh layers Removing the PURIFICATION PLATE 1 Grasp the PURIFICATION PLATE on the ceramic and gently pull it out of the grooves on the sides 2 Clean see CLEANING page 16 and set the PURIFICATION PLATE aside Removing the PCO CELL 1 Locate the PCO CELL Connector on the right of the rear of the ClearAir Whole Home Air P...

Страница 8: ...ON PLATE slot and significant resistance is met Be careful not to force the PURIFICATION PLATE further into the PURIFICATION PLATE slot as this could seriously damage your ClearAir Whole Home Air Purifier Installing the FILTER ASSEMBLY 1 Hold the FILTER ASSEMBLY with the larger flat side where the honeycomb layer of the filter is visible facing the interior of the ClearAir Whole Home Air Purifier ...

Страница 9: ...the exterior with a damp cloth or use compressed air or a vacuum cleaner to remove dust Cleaning the FILTER ASSEMBLY You may use clean water or compressed air to clean your FILTER ASSEMBLY once it has been disassembled see DISASSEMBLY on page 12 After disassembling your ClearAir Whole Home Air Purifier the three filters mesh foam and honeycomb should be removed and cleaned separately If using wate...

Страница 10: ...itations may not apply to you Your relief for the breach of this warranty is limited to the relief expressly provided above In no event shall Mercola com Health Resources LLC be liable for any consequential or incidental damages you may incur in connection with your purchase or use of the ClearAir Whole Home Air Purifier Some states do not allow the exclusion or limitation of incidental or consequ...

Страница 11: ...DISTRIBUTED BY NHP 125 SW 3rd Place Cape Coral FL 33991 USA 877 985 2696 Made in China 20276 v400N ...

Отзывы: