![dr. Mercola Whole Home Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/dr-mercola/whole-home/whole-home_owners-manual_2526065008.webp)
14
15
Assembly
Assembly
Refer to “TOOLS & WORKSPACE” from “DISASSEMBLY” on Page 12
Installing the FRONT GRILLE:
1 . Gently set the bottom of the FRONT GRILLE in place on the lower front of the
Clear
Air
Whole Home Air Purifier and swing the top of the FRONT GRILLE into
place, being careful not to damage the IONIZATION NEEDLE at the top center of
the front of the Clear
Air
Whole Home Air Purifier .
2 . Insert the FOUR FRONT GRILLE SCREWS one at a time until they are in place, but
not tight. After all FRONT GRILLE SCREWS are in place, tighten them carefully.
Installing the PCO CELL:
1 . Position the PCO CELL inside the Clear
Air
Whole Home Air Purifier so that the
two tabs are on the bottom of the PCO CELL. Ensure the holes in the two tabs fit
over the two screw posts. Screw the PCO CELL RETAINING NUTS onto the screw
posts until they are snug .
2 . Align the PCO CELL CONNECTOR to the PCO CELL CONNECTOR outlet and insert
gently until the tabs at the top and bottom of the PCO CELL CONNECTOR snap
into place, holding it in the PCO CELL CONNECTOR outlet .
Installing the PURIFICATION PLATE:
1 . Holding the PURIFICATION PLATE by the ceramic, slowly insert it into the
PURIFICATION PLATE slot, ensuring that the PURIFICATION PLATE is properly
sliding into the grooves on either side .
NOTE: About halfway in, the PURIFICATION PLATE connectors are parted.
Continue sliding the PURIFICATION PLATE into the PURIFICATION PLATE slot until
there is approximately one inch of the PURIFICATION PLATE remaining outside of
the PURIFICATION PLATE slot and significant resistance is met. Be careful not to
force the PURIFICATION PLATE further into the PURIFICATION PLATE slot as this
could seriously damage your Clear
Air
Whole Home Air Purifier .
Installing the FILTER ASSEMBLY:
1 . Hold the FILTER ASSEMBLY with the larger flat side (where the honeycomb layer
of the filter is visible) facing the interior of the Clear
Air
Whole Home Air Purifier .
2 . Insert the bottom of the FILTER ASSEMBLY into the tabs on the rear of the
Clear
Air
Whole Home Air Purifier and then seat the FILTER ASSEMBLY on the rear
of the unit. (NOTE: If the user fails to insert the FILTER ASSEMBLY into the tabs
appropriately, disassembling the unit in the future could be extremely difficult .)
3 . Screw the two BRASS THUMBSCREWS into their holes at the top corners of the
FILTER ASSEMBLY.
Installing the REAR COVER:
1 . Place the tabs at the top of the REAR COVER into the holes above the top of
the FILTER ASSEMBLY then swing the REAR COVER flat against the rear of the
Clear
Air
Whole Home Air Purifier and press until the tabs on the inner sides of
the REAR COVER click into place in the unit .
2 . Carefully insert the REAR COVER SCREW into its hole on the REAR COVER (above
the POWER CORD Port) and tighten .
Installing the POWER CORD:
1 . Insert the DC POWER ADAPTER PLUG into the rear of the Clear
Air
Whole Home
Air Purifier .
2 . Ensure the POWER CORD is properly connected to the DC POWER ADAPTER .
3 . Insert the POWER CORD PLUG into a wall outlet.
Turning the Clear
Air
Whole Home Air Purifier On:
1 . Press the POWER BUTTON .
2 . The Clear
Air
Whole Home Air Purifier will be set to NORMAL MODE (PCO) once
again . Ensure that the settings are adjusted to suit your preferences (see
“CONTROLS” on page 11).