Self-Regulating Heating Cables for Pipes

 

CHOOSING A CABLE 

 Make sure to choose a cable longer than the pipe ensure coverage.

 

 

NOTE: For each valve or spigot on pipe an additional foot of cable is needed. When the cable is longer than the pipe, 
spiral the excess cable around the pipe length evenly.

 

 

 
 
 
 
 
 
 
 
 
 
 

ATTACHING CABLE TO PIPE

 

1. Prior to installing the cable, be sure 

all piping is dry, and any sharp 
surfaces are removed.

 

2. Attach heating cable to pipe with 

straight, spiraling or multiple tracing.

 

3. If the heating cable is the same 

length as the pipe, run it straight 
along the bottom of the pipe. If two 
cables are required, position them in 
the 4 and 8 o’clock positions. If three 
cables are required, position them in 
the 11 

o’clock k or 1 o’clock 

positions and 4 

o’clock and 8 o’clock 

positions.

 

 
 
 
 
 
 
 
 
 
 
 

4. If the cable is less than double the 

pipe length, spiral the cable over 
the length of pipe.

 

5. Any excess cable remaining at the 

end of the pipe can be doubled 
back along the  pipe.

 

6. Be  sure  to  include  any  additional 

heating  cable  required  for  valves, 
spigots, etc.

 

7. Secure the cable to the pipe with 

DR-003 fiberglass application tape 
or nylon cable ties. Do not use vinyl 
tape, metallic products or wire.

 

INSTALLING THERMAL INSULATION

 

1. Before insulating, inspect the cable to 

ensure that it is free of mechanical 
damage, such as gouges or cuts, etc.

 

2. Cover the pipe, cables, connections, 

valves with at least 1/2”  (12.7

 

mm) thick fiberglass insulation or 
equivalent. DO NOT leave the 
cables exposed.

 

3. Use fire-resistant materials such 

as fiberglass wrap. Make sure the 
insulation is waterproofed (with

 

polyethylene or other vapor barriers) 
in areas where water may come in 
contact with the insulation.

 

4. Place  the  two  warning  labels  on  the 

outer  surface  of  the  pipe  insulation 
where  clearly  visible  and  at  suitable 
locations to indicate the presence

 

of electric heating cable.

 

5. After installation is complete, turn the 

circuit breaker on to give power to the 
cable. Standing water in the pipe 
should feel warm within one hour.

 

 

MAINTENANCE CHECKS 

1.

 

Only 

qualified

 persons should service or install the system. 

2.

 

Check yearly for any damage to the heating cable and check any ground fault protection device for proper operation. 

If any damage to cable is found, DO NOT operate until it is replaced. 
 

Self-Regulating Heating Cables for Pipes Package Content 

1.  Self-Regulating Heating Cable (DR-9RCxxxx) 

2.  Warning label x 2 
 
Fiberglass tape (DR-003) *sold separately 

 

 

 

 

 

 

Содержание DR-9RC 120V

Страница 1: ...Self Regulating Heating Cables For Pipes and Roof De Icing Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...tion such as fiberglass or preformed foam Do not embed heating cable in the insulation 4 Use 1 2 to 1 fiberglass tape or plastic cable ties when attaching cable to pipe Do not use wire or metal clamps Specifications General Safety Information Read and understand all instructions in this manual and the following installation instructions and Safety Warnings Electrical cables if not installed correctly...

Страница 3: ...s application tape or nylon cable ties Do not use vinyl tape metallic products orwire INSTALLING THERMAL INSULATION 1 Before insulating inspect the cable to ensure that it is free of mechanical damage such as gouges or cuts etc 2 Cover the pipe cables connections valves with at least 1 2 12 7 mm thick fiberglass insulation or equivalent DO NOT leave the cables exposed 3 Use fire resistant material...

Страница 4: ...so be installed in any nearby gutters downspouts and or valleys If you need to apply the cable on a roof with gutter downspouts valleys and or dormers follow A For Typical Roof Applications below If you only need to install the cable in the gutters only follow B If you need to install the cable on a roof with special roof areas such as a roof with skylights follow C For Roofs with Special Roof Are...

Страница 5: ...5 125 120V 1000 1125 1500 I DR 9RC2200 200 240V 1600 1800 2400 J DR 9RC2250 250 240V 2000 2250 3000 B For Problem in The Gutter Only If ice dams are occurring in gutters only measure the required dimensions see Figure 5 and calculate the length of the cable needed for each area listed in Table 4 Add each area calculation to determine the total cable length needed C For Roofs with Special Roof Area...

Страница 6: ...his example shows how to estimate the cable length needed for a limited problem roof area a skylight see Figure 6 For this roof you would like to treat only the problem area underneath the skylight This roof section has 1 downspout l0 feet long 1 skylight the distance from the bottom of the skylight to the roof edge is 12 5 feet and the width of the ice dams that form beneath the skylight is about...

Страница 7: ... TIP If you will be working directly on the roof during the installation you may want to mark the cable pattern with chalk before attaching the cable If working from a ladder you will probably want to lay out the pattern as you attach the cable with the clips Making a drawing of your roof and your planned pattern on paper may be helpful Pattern for the Roofline Cable laid along the roofline is arr...

Страница 8: ...nd downspouts and select a heater that will not exceed their temperature ratings Figure 9 Double cable run in the gutter downspouts 1 Use hanger bracket to support the heating cable where it enters a downspout to prevent cable from being damaged by gutter edge It also can be used as spacers in wider gutters 2 Run heating cable over top of hanger and secure to hanger using UV resistant cable ties 3...

Страница 9: ...ing tips and service instructions if needed Self Regulating Heating Cables forPipes Package Content 1 Self Regulating Heating Cable DR 9RCxxxx x 1 2 Warning label x 2 3 UV resistant cable ties Roof clips DR 006 sold separately Warranty Information Register your product at our website Or visit DrHeaterUSA com register your heater Feedback Love it Help us make the product more for you Let us know wi...

Отзывы: