Please read and save these instructions. Read carefully before installation, operate or maintain the product described. Protect yourself and others by observing all 

safety information. 

Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. 

Plug-In Self-Regulating Heating Cables 

Product Introduction 

These heating cables provide pipes, roof and gutter systems protection from damage due to 

freezing, and can be used in residential and commercial applications. The cables automatically 

adjust heat output according to the ambient temperature conditions. Under cooler conditions the 

heat output increases, and as the temperature rises the output decreases to save on energy. 

The cables operate on 120V / 240V and are available in various pre-assembled lengths. 

Features 

-

 

Pre-assembled cable lengths include 
a 6ft power cord and plug 

-

 

Suitable for plastic or metal pipes, 
gutters and downspouts 

-

 

Ease of installation, as the cable 
can be overlapped without the risk 
of becoming overheated or burnt. 

1.

 

Installation must be in compliance 
with National Electrical Codes (NEC). 

2.

 

Use 30 mA ground fault protection on 
each heating cable branch circuit for 
maximum protection. 

3.

 

Use only 

re-resistant insulation, 

such as 

berglass or preformed 

foam. Do not embed heating cable 
in the insulation. 

4.

 

Use 1/2

 to 1

 

berglass tape or 

plastic cable ties when attaching 
cable to pipe. Do not use wire or 
metal clamps. 

 

Speci

cations 

General Safety Information 

Read and understand all instructions in this 

manual and the following installation 

instructions and Safety Warnings. Electrical 

cables, if not installed correctly or are 

damaged, can present a 

re, shock and 

arcing 

hazard. 

 

 

5.

 

Before installing or servicing, ensure 
that all power to circuits is OFF. 

6.

 

Do  not  twist  cable  during 
installation. 

7.

 

Do  not  install  heating  cable  under 
roo

ng material. 

8.

 

Do not expose cable to 
temperatures above 150

°

F, as this 

will damage the cable. 

9.

 

Do not use extension cords. 

10.

 

Save  all  instructions  for  future 

reference. 

 
 

 
 
 

 

 
 
 

 

 

Do not use damaged heating 
cables, power cord or plug. 
Remove and replace immediately 

to prevent a 

re, shock, or arcing 

hazard. 
 

 

Cable # 

Model No. 

length(ft) 

Volt(V) 

Power Output(W) 

On Pipe 

@50°F / 10°C 

On Pipe 

@5°F / 40°C 

In-Ice water 

@32°F / 0°C 

DR-9RC1006 

120V 

48 

54 

72 

DR-9RC1012 

12 

120V 

96 

108 

144 

DR-9RC1018 

18 

120V 

144 

162 

216 

DR-9RC1024 

24 

120V 

192 

216 

288 

DR-9RC1050 

50 

120V 

400 

450 

600 

DR-9RC1075 

75 

120V 

600 

675 

900 

DR-9RC1100 

100 

120V 

800 

900 

1200 

DR-9RC1125 

125 

120V 

1000 

1125 

1500 

DR-9RC2200 

200 

240V 

1600 

1800 

2400 

DR-9RC2250 

250 

240V 

2000 

2250 

3000 

    

Operating Instructions & Parts  Manual                                                             

DR-9RC 120V /  DR-9RC 240V

 

120V 

240V 

Содержание DR-9RC 120V

Страница 1: ...Self Regulating Heating Cables For Pipes and Roof De Icing Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...tion such as fiberglass or preformed foam Do not embed heating cable in the insulation 4 Use 1 2 to 1 fiberglass tape or plastic cable ties when attaching cable to pipe Do not use wire or metal clamps Specifications General Safety Information Read and understand all instructions in this manual and the following installation instructions and Safety Warnings Electrical cables if not installed correctly...

Страница 3: ...s application tape or nylon cable ties Do not use vinyl tape metallic products orwire INSTALLING THERMAL INSULATION 1 Before insulating inspect the cable to ensure that it is free of mechanical damage such as gouges or cuts etc 2 Cover the pipe cables connections valves with at least 1 2 12 7 mm thick fiberglass insulation or equivalent DO NOT leave the cables exposed 3 Use fire resistant material...

Страница 4: ...so be installed in any nearby gutters downspouts and or valleys If you need to apply the cable on a roof with gutter downspouts valleys and or dormers follow A For Typical Roof Applications below If you only need to install the cable in the gutters only follow B If you need to install the cable on a roof with special roof areas such as a roof with skylights follow C For Roofs with Special Roof Are...

Страница 5: ...5 125 120V 1000 1125 1500 I DR 9RC2200 200 240V 1600 1800 2400 J DR 9RC2250 250 240V 2000 2250 3000 B For Problem in The Gutter Only If ice dams are occurring in gutters only measure the required dimensions see Figure 5 and calculate the length of the cable needed for each area listed in Table 4 Add each area calculation to determine the total cable length needed C For Roofs with Special Roof Area...

Страница 6: ...his example shows how to estimate the cable length needed for a limited problem roof area a skylight see Figure 6 For this roof you would like to treat only the problem area underneath the skylight This roof section has 1 downspout l0 feet long 1 skylight the distance from the bottom of the skylight to the roof edge is 12 5 feet and the width of the ice dams that form beneath the skylight is about...

Страница 7: ... TIP If you will be working directly on the roof during the installation you may want to mark the cable pattern with chalk before attaching the cable If working from a ladder you will probably want to lay out the pattern as you attach the cable with the clips Making a drawing of your roof and your planned pattern on paper may be helpful Pattern for the Roofline Cable laid along the roofline is arr...

Страница 8: ...nd downspouts and select a heater that will not exceed their temperature ratings Figure 9 Double cable run in the gutter downspouts 1 Use hanger bracket to support the heating cable where it enters a downspout to prevent cable from being damaged by gutter edge It also can be used as spacers in wider gutters 2 Run heating cable over top of hanger and secure to hanger using UV resistant cable ties 3...

Страница 9: ...ing tips and service instructions if needed Self Regulating Heating Cables forPipes Package Content 1 Self Regulating Heating Cable DR 9RCxxxx x 1 2 Warning label x 2 3 UV resistant cable ties Roof clips DR 006 sold separately Warranty Information Register your product at our website Or visit DrHeaterUSA com register your heater Feedback Love it Help us make the product more for you Let us know wi...