DR. BENDER BELUGA SXC Скачать руководство пользователя страница 14

 

14 

7.2 

Service after 120 operating hours 

 
A  service  is  due  after  120  operating  hours.  The  machine  counts  the  operating  hours  itself  and  tells  you 
when 120 operating hours are reached by a blue LED on the handle. All worn parts are replaced during this 
service. The next service is carried out at further intervals of 120 operating hours. The service interval may 
be extended by max. 10 %, so you can complete your work with the machine at your own convenience. 
If  the maximun  service  interval  of  120  +  12  operating  hours  is  exceeded,  the  warranty  becomes  null  and 
void.  
 
 

7.3 

Quarterly 

 
Have the cables, switches, plugs checked by a qualified specialist (provision pursuant to VBG4) and record 
this. Replacing the gearbox oil significantly increases the service life of the gearbox. 
 
 

8.0 

Speed setting depending on cutting speed 

 
The drive units of the Beluga series allow stepless speed adjustment. You can thus set the best cutting 
speed for your drill bit. This also provides a perfect, quick cut and the service life of the tool is also 
significantly extended. 
 
 

9.0 

Warranty 

 
Pursuant to our Terms & Conditions of Sale, we offer a warranty of 12 months from the date of purchase. 
This covers the free repair of material and production defects which are shown to have been caused prior 
to sale.  
 
An original sales receipt must always be produced when asserting a warranty claim. It must include the full 
address of the dealer, purchase date, and type code of the product. The user manual for the relevant prod-
uct as well as the safety instructions must have been followed. 
Damage caused by operating errors is not covered by the warranty. 
The  manufacturer’s  products  are  developed  and  built  for  specific  applications.  If  the  product  is  used  for 
purposes other than the intended purpose based on the user manual, or in the event of misuse, or if unap-
proved accessories are used, the warranty shall become null and void. 
The products must be regularly maintained and cleaned according to the instructions in the user manual. 
The warranty shall become null and void in the event of an intervention by third parties (opening the ma-
chine). 
The warranty does not cover maintenance and cleaning work. 
You must ensure that only original spare parts and accessories are used. The products must be purchased 
from an authorised dealer. If non-original parts are used, this may result in consequential damage and in-
creased risk of accidents. The manufacturer is not liable for such damage. Disassembled, partially disas-
sembled units, and units repaired with third party parts are not covered by the warranty. 
 
Certain  parts  are  subject  to  normal  wear  and  tear  depending  on  use.  These  parts  include  e.g.  carbon 
brushes, ball bearings, switches, mains cables, seals, etc. These consumable parts are not covered by the 
warranty. Consumable parts are highlighted in the spare parts lists. 
 
 

10.0  General Safety instructions 

 
The general safety instructions can be found in the supplied safety instruction booklet. 
 
 
 
 

 
 

Содержание BELUGA SXC

Страница 1: ...ating Manual Drive unit Beluga sXc SXD HF III Issued 11 2015 Subject to change All rights reserved DR BENDER GmbH D 75382 Althengstett Tel 07051 9291 0 Fax 07051 9291 91 We are on the internet at http...

Страница 2: ...mpatibility EMC 2004 108 EC Low Voltage Directive 2006 95 EC The following harmonised standards have been used for assessment of the appliance EN 50144 1 EN 50144 2 1 EN 55014 1 EN 61000 3 2 EN 61000...

Страница 3: ...2 Beluga SXD 10 4 3 Noise emission and vibration EN 50144 10 4 4 Operating temperatures 10 5 0 Commissioning 11 5 1 Mains connection 11 5 2 Water connection 11 5 3 Operation panel 12 5 4 Drill bits 1...

Страница 4: ...Symbol and pictogram description Attention Indicates instructions may endanger your health or the functionality of the unit if they are not followed The warranty shall become null and void if you cau...

Страница 5: ...afety signs on the unit Wear safety shoes Wear protective gloves Wear protective helmet Wear protective goggles Wear ear protection Wear respiratory mask Disconnect power before working Read instructi...

Страница 6: ...ption Drill spindle 1 UNC Drill spindle 1 UNC Switch box Nameplate Mains connection beluga SX D Nameplate Water connection Beluga SXC Base Switch box halves Mains connection Base Operation panel Air i...

Страница 7: ...control This enables the best speed to be assigned to each tool diameter in order to attain the best possible cutting speed on the tool During work the speed can be steplessly reduced if you come up...

Страница 8: ...ulations the correct use of tools the use of personal protective equipment 3 0 Transport and storage 3 1 Transport Warning The drive units must be inspected for transport damage after receipt Any dama...

Страница 9: ...9 4 0 Main dimensions and technical data 4 1 Dimensions 4 1 1 Beluga SX C 4 1 2 Beluga SX D...

Страница 10: ...ent rating 18 16 A Power consumption 12 000 3 700 W Frequency 50 60 Hz Idle full load speed continuously variable 0 850 min 1 Power output 8 200 2 400 W Torque 220 120 Nm Drilling diameter 40 450 mm W...

Страница 11: ...st first flow through the Powerbox then through the drive unit and only then to the drill bit Therefore connect the water supply to the water line with tap provided on the Powerbox Attention If possib...

Страница 12: ...rilling motors this value should always be set to 100 to obtain the maximum speed of the drill spindle The panel of Beluga SXW SXC now showing Speed 000 min 1 and the green LED is flashing By pressing...

Страница 13: ...s daily inspection when operating the units cooling water must not penetrate the electrical components in whichever location the units are used If water is dripping from the unit stop work and take th...

Страница 14: ...ull address of the dealer purchase date and type code of the product The user manual for the relevant prod uct as well as the safety instructions must have been followed Damage caused by operating err...

Страница 15: ...no Description No 1 302189 Driving machine SXC 1 2 302197 Motor complete 1 3 302186 Gear complete 1 4 802463 Water connection complete 1 5 802402 Thread nipple 1 6 802464 Hose 1 7 801801 Ball valve c...

Страница 16: ...16 11 2 Driving machine SXD Item Part no Description No 1 302221 Driving machine SXD 1 2 302222 Motor complete 1 3 302186 Gear complete 1 4 802402 Nipple 1 5 802464 Hose 1 Wearing parts...

Страница 17: ...17...

Страница 18: ...18 11 3 Motor complete SXC...

Страница 19: ...1 18 802433 Hexagon socket head cap screw with centre hole 4 19 102445 Switch box half left 1 20 803019 Sealing tape 2 21 802713 Keypad 1 22 802792 Passage grommet 1 23 102438 Platine complete 1 24 10...

Страница 20: ...20 11 4 Motor complete SXD...

Страница 21: ...n socket head cap screw with centre hole 3 21 102010 stored cap 1 22 800391 Sealing ring 4 23 802197 Hexagon socket head cap screw with centre hole 4 24 900231 Washer 1 25 900181 Wave spring washer 1...

Страница 22: ...22 11 5 Gear complete...

Страница 23: ...sing 1 16 901139 Groove ball bearing 1 17 301385 Pinion shaft 2 1 18 901071 Parallel pin 2 19 302267 Gear 2 slip coupling 1 20 302249 Hub 1 21 401563 Brake disc 4 22 401562 Support washer I 2 23 40133...

Отзывы: