Wire-Wrap Connector Pin-Outs

Fig. 13 shows the pin-outs for the wire-wrap connectors at

the board edge interface. Non-connectorized models connect
directly to the wire-wrap connectors.

Docking Module Locations

Fig. 12 shows the locations of the Docking Pads on the MUX

board. The electrical interface of each port is determined by the
module installed in the docking pad. Modules available include
RS232, RS422/485, T202 modem and T212 dial modem.

Specifications

Dimensions: 17.0"(W) X 12.0"(D) X 1.75"(H)

Mounting:

The MUX rack unit can be mounted in a 19"

23" rack. The MUX unit can also be wall

mounted.

Power Input: -24 DC unit: -18 to -36 VDC @ 210 mA

-48 DC unit: -36 to -72 VDC

@ 190 mA (max) 30 mA (typical)

Fuse:

1/2 Amp

Operating Temperature Range:

0 degrees to +60 degrees Celsius.

Humidity:

0% to 95% non-condensing

Interface:

1 RS232 (DB9) Craft Port on the front,
Connectorized models:

9 DB9 connectors on the back.

1 3-terminal barrier block

Wire wrap models:

2 56-pin wire wrap connectors

All specifications are subject to change without notice.

Options & Model Numbers

The MUX part numbers and options are listed below. These

options are constantly expanded. As a result, more options may
be available than are listed below. Contact your distributor for
currently available options.

D-PC-181-10A-1V

TL1 MUX-8: Connectorized,
RS232 Common Port, 1200 Baud
202 Modem on Ports 1-8.

D-PC-182-10A-0V

TL1 MUX-8: Wire wrap,8
RS232 ports

D-PC-182-10A-2V

TL1 MUX-8: Connectorized,
8 RS232 ports

V= Voltage:

2 = -24 VDC
4 = -48 VDC

Docking modules

:

D-PC-635-10A-00

202/1200 Baud Modem

D-PC-645-10A-00

RS232

D-PC-655-10A-00

RS422/485

D-PC-140-10A-00

212 Dialup Modem

8

D-PC-180-10A-XV
November 5, 1997

4922 East Yale Avenue - Fresno, CA 93727 - Phone (209) 454-1600 / (800) 622-3314 - FAX (209) 454-1688

e-mail: [email protected]

Visit our Web site at http://www.dpstele.com

DPS INC

"Your Partners in Telemetry Monitoring Systems"

Содержание TL1 MUX-8

Страница 1: ...2 and 212 type modems The mo dems are sold separately so that each port can be equipped with the desired type modem The TL1 MUX 8 is housed on a plug in board that fits in a 1 3 4 rack mount housing The back of the housing provides DB9 connectors for connecting the associated devices The ac tual MUX board can be changed rapidly without removing any of the connections The front panel of the TL1 MUX...

Страница 2: ...stalled Connect the MUX craft port to a PC and load the T MUX software Refer to the Configuration section below for more information When configuration is complete disconnect the computer The MUX will continue operation with no furthur intervention Configuration The MUX is configured with a program callled T MUX T MUX runs under a host program called T Config which can host configuration software ...

Страница 3: ...tions Screen Field Name Description Msg Timeout Time to delay before aborting an incomplete TL1 mes sage Enter in tenths of seconds 10 255 Default is 10 Baud Off 300 1200 2400 and 9600 Parity EVEN NONE ODD Word Length 7 BITS 8 BITS Stop Bits 1 BIT 2 BITS Interface TTL RS232 RS422 RS485 202 Hot Keys available in the Edit MUX Configuration screen are shown on the line at the bottom of the screen See...

Страница 4: ...th sub menu does not apply to the MUX Communica tions field values are listed in Table E Table E Field Names and Descriptions in the T MUX Communications Parameters Window Field Name Description COM PC Com Port number 1 4 BAUD Set only at 9600 Baud STOP BITS Select 1 DATA BITS Select 8 PARITY Select NONE MAX TIMEOUT Time to wait for a response 50 9999 Milleseconds Default is 3000 MAX RESEND Number...

Страница 5: ...Port is a female RS232 DB9 connector used as a direct link into the MUX It is normally used to configure or monitor the MUX See Fig 11 NOTE When the craft port is in use the MUX port is not ac tive D PC 180 10A XV 5 OG1074A7 November 5 1997 FA CRAFT PORT A1 A2 A3 A4 1 2 6 4 5 6 7 8 RLY ACK ALM CM1 LOD ER1 LOC CFG DPS INC TL1 Mu X 8 ALARMS TL1 PORTS Fig 10 LED Indicators on the Front Panel Show Ope...

Страница 6: ...data on respective port RD Indicates receiving data on respective port 6 D PC 180 10A XV November 5 1997 COMMON PORT PORTS 1 8 FUSE ALARM AND CONTROLS ALARM POINTS 1 4 J20 J22 Not Used DB9 FEMALE CONNECTORS POWER TERMINAL BLOCK J9 J10 J11 J12 J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 BATT GND GND Fig 11 Signal Lines Connect at Wire Wrap Pins on the Back of the Shelf J9 6 N C 7 DCD 8 DTR 9 N C 1 N C ...

Страница 7: ... PORT 6 N C N C N C PIN DESCRIPTION PIN DESCRIPTION J1 Pin Layout 202 MODEM RS 232 202 MODEM RS232 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 RX PORT 7 TX PORT 7 TX PORT 7 RX PORT 8 TX PORT 8 TX PORT 8 N C N C CTRL 1 COM CTRL 1 N C ALARM 1 ALARM 2 ALARM 3 ALARM 4 N C CTS PORT 7 TXD P...

Страница 8: ... the front Connectorized models 9 DB9 connectors on the back 1 3 terminal barrier block Wire wrap models 2 56 pin wire wrap connectors All specifications are subject to change without notice Options Model Numbers The MUX part numbers and options are listed below These options are constantly expanded As a result more options may be available than are listed below Contact your distributor for curren...

Отзывы: