Wire-Wrap Connector Pin-Outs
Fig. 13 shows the pin-outs for the wire-wrap connectors at
the board edge interface. Non-connectorized models connect
directly to the wire-wrap connectors.
Docking Module Locations
Fig. 12 shows the locations of the Docking Pads on the MUX
board. The electrical interface of each port is determined by the
module installed in the docking pad. Modules available include
RS232, RS422/485, T202 modem and T212 dial modem.
Specifications
Dimensions: 17.0"(W) X 12.0"(D) X 1.75"(H)
Mounting:
The MUX rack unit can be mounted in a 19"
23" rack. The MUX unit can also be wall
mounted.
Power Input: -24 DC unit: -18 to -36 VDC @ 210 mA
-48 DC unit: -36 to -72 VDC
@ 190 mA (max) 30 mA (typical)
Fuse:
1/2 Amp
Operating Temperature Range:
0 degrees to +60 degrees Celsius.
Humidity:
0% to 95% non-condensing
Interface:
1 RS232 (DB9) Craft Port on the front,
Connectorized models:
9 DB9 connectors on the back.
1 3-terminal barrier block
Wire wrap models:
2 56-pin wire wrap connectors
All specifications are subject to change without notice.
Options & Model Numbers
The MUX part numbers and options are listed below. These
options are constantly expanded. As a result, more options may
be available than are listed below. Contact your distributor for
currently available options.
D-PC-181-10A-1V
TL1 MUX-8: Connectorized,
RS232 Common Port, 1200 Baud
202 Modem on Ports 1-8.
D-PC-182-10A-0V
TL1 MUX-8: Wire wrap,8
RS232 ports
D-PC-182-10A-2V
TL1 MUX-8: Connectorized,
8 RS232 ports
V= Voltage:
2 = -24 VDC
4 = -48 VDC
Docking modules
:
D-PC-635-10A-00
202/1200 Baud Modem
D-PC-645-10A-00
RS232
D-PC-655-10A-00
RS422/485
D-PC-140-10A-00
212 Dialup Modem
8
D-PC-180-10A-XV
November 5, 1997
4922 East Yale Avenue - Fresno, CA 93727 - Phone (209) 454-1600 / (800) 622-3314 - FAX (209) 454-1688
e-mail: [email protected]
Visit our Web site at http://www.dpstele.com
DPS INC
"Your Partners in Telemetry Monitoring Systems"