background image

Product Summary

June 14, 2002

UM026.14100

www.dpstele.com

(800)622-3314

User Manual

NIA Card

Figure 1 - 

NIA card with blank KDA shelf.

Overview

DPS’ Network Interface Adapter fits in the expansion card slot of the KDA shelf. It interfaces directly to an Ethernet

10BaseT network using SNMP protocol. 

The unit is easy to install, with connectors for all serial and LAN ports and it

mounts quickly in either 19" or 23" equipment racks while occupying only one rack unit of space.

19" or 23" Rack/

5" Projection

19" or 23" Rack/

Flush Front

19" or 23" Rack/

5-1/2" Projection

19" or 23" Rack/

1/2" Projection

SIDE VIEW

REAR

NOTE: Use wide ears for 23"

19" or 23" Rack/

7" Projection

Mounting Instructions

The unit can be mounted in a 19” or 23” rack by using the reversible rack ears for either size (provided). Several rack ear

locations are available. Attach the ears for your rack using either the 7”, 5 1/2”, 5”, 1/2”, or 0” (flush mount) projection. See
the figure below for mounting options.

Figure 2 - 

The KDA offers several mounting options.

Содержание NIA Card

Страница 1: ...r 19 or 23 equipment racks while occupying only one rack unit of space 19 or 23 Rack 5 Projection 19 or 23 Rack Flush Front 19 or 23 Rack 5 1 2 Projection 19 or 23 Rack 1 2 Projection SIDE VIEW REAR NOTE Use wide ears for 23 19 or 23 Rack 7 Projection Mounting Instructions The unit can be mounted in a 19 or 23 rack by using the reversible rack ears for either size provided Several rack ear locatio...

Страница 2: ...ed with the unit connect black to GND and red to BATT Standard gauge is 20AWG which varies from 18 24AWG 5 4 3 2 1 9 8 7 6 DSR GND RX TX RTS CTS Female PIN Signal Description 1 2 3 4 5 6 7 8 9 NC TX RX DSR GND NC CTS RTS NC Not connected Transmit data Receive data Data set ready Ground Not connected Clear to send Request to send Not connected 1 2 3 4 5 6 7 8 9 DSR GND RX TX RTS CTS Male PIN Signal...

Страница 3: ...type E for E dit and then I for I P Parameters 2 Enter the IP Address the Subnet Mask and Default Gateway NIAT v2 2F Configuration E dit W rite e X it E I P Parameters P ass thru Port I Unit Address 126 010 230 102 SubNet Mask 255 255 255 000 Default Gateway 126 010 230 001 U nit Address S ubnet Mask D efault Gateway Pass thru Port 1 To edit the Pass thru Port information type E for E dit and then...

Страница 4: ... that allow users to monitor larger more complicated networks with a smaller less trained staff Your Partners in Network Alarm Management www dpstele com 4955 E Yale Avenue Fresno CA 93727 559 454 1600 800 622 3314 559 454 1688 fax ...

Отзывы: