DPS Telecom NetGuardian 832/864A Скачать руководство пользователя страница 43

Warranty

DPS Telecom warrants, to the original purchaser only, that its products a) substantially conform to DPS' published
specifications and b) are substantially free from defects in material and workmanship. This warranty expires two years from the
date of product delivery with respect to hardware and ninety days from the date of product delivery with respect to software.
If the purchaser discovers within these periods a failure of the product to substantially conform to the specifications or that
the product is not substantially free from defects in material and workmanship, the purchaser must promply notify DPS. Within
reasonable time after notification, DPS will endeavor to correct any substantial non-conformance with the specifications or
substantial defects in material and workmanship, with new or used replacement parts. All warranty service will be performed at
the company's office in Fresno, California, at no charge to the purchaser, other than the cost of shipping to and from DPS,
which shall be the responsiblity of the purchaser. If DPS is unable to repair the product to conform to the warranty, DPS will
provide at its option one of the following: a replacement product or a refund of the purchase price for the non-conforming
product. These remedies are the purchaser's only remedies for breach of warranty. Prior to initial use the purchaser shall have
determined the suitability of the product for its intended use. DPS does not warrant a) any product, components or parts not
manufactured by DPS, b) defects caused by the purchaser's failure to provide a suitable installation environment for the
product, c) damage caused by use of the product for purposes other than those for which it was designed, d) damage caused
by disasters such as fire, flood, wind or lightning unless and to the extent that the product specification provides for
resistance to a defined disaster, e) damage caused by unauthorized attachments or modifications, f) damage during shipment
from the purchaser to DPS, or g) any abuse or misuse by the purchaser.

THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.

In no event will DPS be liable for any special, incidental, or consequential damages based on breach of warranty, breach of
contract, negligence, strict tort, or any other legal theory. Damages that DPS will not be responsible for include but are not
limited to, loss of profits; loss of savings or revenue; loss of use of the product or any associated equipment; cost of capital;
cost of any substitute equipment, facilities or services; downtime; claims of third parties including customers; and injury to
property.

The purchaser shall fill out the requested information on the Product Warranty Card and mail the card to DPS. This card
provides information that helps DPS make product improvements and develop new products.

For an additional fee DPS may, at its option, make available by written agreement only an extended warranty providing an
additional period of time for the applicability of the standard warranty.

Technical Support

If a purchaser believes that a product is not operating in substantial conformance with DPS' published specifications or there
appear to be defects in material and workmanship, the purchaser should contact our technical support representatives. If the
problem cannot be corrected over the telephone and the product and problem are covered by the warranty, the technical
support representative will authorize the return of the product for service and provide shipping information. If the product is
out of warranty, repair charges will be quoted. All non-warranty repairs receive a 90-day warranty.

Содержание NetGuardian 832/864A

Страница 1: ...USER MANUAL SiteDialer for NetGuardian 832 864A Family December 13 2016 Visit our website at www dpstelecom com for the latest PDFmanual and FAQs D UM SDNGV 12001 Firmware Version 1 0A...

Страница 2: ...ired by United States copyright laws The material in this manual is for information purposes and is subject to change without notice DPS Telecom shall not be liable for errors contained herein or cons...

Страница 3: ...ettings 6 12 via Craft Port 6 1 12 via LAN 6 2 15 TTY Interface 6 3 16 Ethernet Configuration 6 4 17 Quick Start Configuring Your SiteDialer to Receive Alarms from a NetGuardian 7 18 Firmware Upgrade...

Страница 4: ...End User License Agreement 13 36...

Страница 5: ...lerts will be sent to your phone SNMP traps will also be sent to your SNMP manager Dial right into the SiteDialer to hear your custom voice alerts and acknowledge alarms remotely via DTMF Easy install...

Страница 6: ...8 VDC 40 to 70 VDC Other options available upon request Mounting Wall or 19 rack Size 1 RU Interfaces 1 RJ45 10BaseT Half Duplex Ethernet Port 1 DB9 Rear Panel Craft Port 1 RJ11 Telco Jack Visual Inte...

Страница 7: ...se refer to the part numbers listed and call DPS Telecom at 1 800 622 3314 SiteDialer D PK VBNGD or D PK SDNGV SiteDialer User Manual D UM SDNGV 12001 SiteDialer Resource CD 6 ft DB9M DB9F Download Ca...

Страница 8: ...crews 2 000 6250 01 x 2 Two Metric Rack Screws 2 000 80750 03 x 4 Four 3 8 Ear Screws 1 000 60375 05 x 2 1 2 Amp Fuse 2 741 0500 00 2 Pin Barrier 2 820 00862 02 Optional Accessories 24V Wall Transform...

Страница 9: ...5...

Страница 10: ...iteDialer you ll need the following tools Phillips No 2 Screwdriver For rack mounting NOTE To install the SiteDialer in one of the wall mount configurations you will also require a wrench or driver ca...

Страница 11: ...ount the SiteDialer vertically on the wall Wall Mounting Instructions The rack ears can be rotated 90 for wall mounting or 180 for other mounting options not shown 1 Depending on your order options yo...

Страница 12: ...aler also mounts on your 19 or 23 equipment racks Rack Mounting Instructions The SiteDialer mounts onto one side of a 19 or 23 rack using the provided rack ear for either size The ear can be rotated 1...

Страница 13: ...ig 5 2 Pinouts for the SiteDialer back panel connections 5 2 1 Power Connection Fig 5 2 1 1 Power connectors and fuse The SiteDialer has one screw terminal barrier plug power connectors located on the...

Страница 14: ...from Power Connector A Note that the plug can be inserted into the power connector only one way this ensures that the barrier plug can only be reinserted with the correct polarity Note that the 48V te...

Страница 15: ...s To connect the SiteDialer to the LAN insert a standard RJ45 Ethernet cable into the 10BaseT Ethernet port on the back of the unit See Fig 5d If the LAN connection is OK the LNK LED will light SOLID...

Страница 16: ...e simplest way to connect to the SiteDialer is over a physical cable connection between your PC s COM port and the unit s craft port Note You must be connected via craft port or Telnet to use the TTY...

Страница 17: ...M port options 6 When prompted enter the default user name admin and password dpstelecom NOTE If you don t receive a prompt for your user name and password check the port you are using on your PC and...

Страница 18: ...Unit Connection Information Now you re ready to do the rest of your configuration via LAN Plug your LAN cable into the SiteDialer and see Section 9 Logging On to the SiteDialer to continue databasing...

Страница 19: ...t IP settings Follow these steps 1 Get a LAN crossover cable and plug it directly into the SiteDialer s LAN port 2 Look up your PC s current IP address and subnet mask and write this information down...

Страница 20: ...he via Craft Port subsection of this chapter over IP address on Port 2002 SiteDialer Telnet sessions are established on port 2002 as a security measure For more instructions on initially connecting to...

Страница 21: ...ave not done so see the previous sections in this chapter to connect to your SiteDialer either via serial craft connection or over LAN 1 When prompted for the password enter dpstelecom 2 Type C for th...

Страница 22: ...o the SiteDialer to database alarm messages 2 Navigate to the Notification Devices tab 3 In an unused row ID enter TCP in the Type column A 4 digit port number in the Pin Rcpt Port column Any port num...

Страница 23: ...rdian s configuration locally You will load this configuration into the SiteDialerEdit program in later steps 9 Install and Run the SiteDialerEdit application from the Resource Disk that came with you...

Страница 24: ...r NetGuardian s configuration file Find your NetGuardian s saved database 16 Click Ok 17 In the top of the SiteDialerEdit window click Connect Write to Unit 18 Enter your SiteDialer s IP address Login...

Страница 25: ...ting the firmware from scratch The Site Dialer Edit software pictured below in section 8 1 is included in the firmware update zip file For more information refer to the SiteDialerEdit user manual Crea...

Страница 26: ...er web browser SiteDialer Web Browser 9 The SiteDialer features a built in Web Browser Interface that allows you to view configurations through the Internet or your Intranet You can quickly view point...

Страница 27: ...page to avoid entering this each time 2 After connecting to the unit s IP address enter your login information and click OK NOTE The factory default username is admin and the password is dpstelecom 3...

Страница 28: ...lowed to simultaneously access the SiteDialer via the Web is 4 Event Log 9 2 Fig 8 2 Event Log Screen The Event Log screen provides you with a log of the last events that have occurred at your NetGuar...

Страница 29: ...25 Test 9 3 Fig 8 3 Test Screen From the Test screen you can test the unit s phone connection by entering a phone number for the SiteDialer to call...

Страница 30: ...ur configuration settings again Backup Configuration Button that allows you to save backup config bin to your PC Upload Config Firmware Web or Bundle Clickable link that takes you to the Load screen w...

Страница 31: ...ween the NetGuardian and SiteDialer Call Settings Call Unit ID Display ID for the Unit Play site name instead of unit id Option to display device name rather than Unit ID when calling out DTMF Passwor...

Страница 32: ...y Priority settings designating which notifications to send out first Notify To notify either On Set On Clear or Both Call list Selected Call List associated with point Escalate If escalate is set the...

Страница 33: ...ions Status Whether Notification has been enabled Type Whether Notification is set to email snmp or dial out Server Server IP Server Port Email server port or SNMP server port To E mail Email address...

Страница 34: ...cts and 2 availability schedules Fig 8 7 Call Lists menu Call Lists Status Whether Notification has been enabled DTMF Password Password set up for acknowledging alarms Schedule 1 to 2 When this Call L...

Страница 35: ...Reboot 9 8 Any change to the SiteDialer s IP configuration requires a reboot To Reboot after any changes have been made select reboot tab and prompt will appear Select OK to reboot Fig 8 8 Reboot Prom...

Страница 36: ...32 Reference Section 10 Call Flow Chart 10 1 The following flowchart outlines the embedded call script The bracketed text refers to customizable voice prompts that you ll create in SiteDialerEdit...

Страница 37: ...Dialer SNMP Trap managers can use one of two methods to get alarm information 1 Granular traps not necessary to define point descriptions for the SiteDialer OR 2 The SNMP manager reads the description...

Страница 38: ...3 6 1 4 1 2682 1 4 5 1 2 99 1 1 1 Object 1 Value 1 3 6 1 4 1 2682 1 4 5 1 3 99 1 1 1 Object 1 Value 1 3 6 1 4 1 2682 1 4 5 1 4 99 1 1 1 Object 1 Value 1 3 6 1 4 1 2682 1 4 5 1 5 99 1 1 1 Object Rectif...

Страница 39: ...to hardware in most terminal programs and this will not work correctly with the SiteDialer SNMP FAQs 11 2 Q Which version of SNMP is supported by the SNMP agent on the SiteDialer A SNMP v1 Q How do I...

Страница 40: ...ve all of the information when you call our Technical Support representatives can assist you in gathering it Please write the information down for easy access Please have your user manual and hardware...

Страница 41: ...f End User in connection with this Agreement This Agreement shall be construed and enforced in accordance with the laws of the State of California without regard to choice of law principles and exclud...

Страница 42: ......

Страница 43: ...lightning unless and to the extent that the product specification provides for resistance to a defined disaster e damage caused by unauthorized attachments or modifications f damage during shipment fr...

Страница 44: ...duct manuals Product datasheets Exclusive user forms Expert tips on using your alarm monitoring equipment advanced techniques that will save you hours of work Educational White Papers deliver fast inf...

Отзывы: