![DPS Telecom D-PG-413-11C-00 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/dps-telecom/d-pg-413-11c-00/d-pg-413-11c-00_user-manual_2525750008.webp)
D-PG-413-11C-00
9
UM118129
August 11, 1999
Table B - Network Connector Pinouts
(DB 15 - DTE)
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Function
TCLK (-) (Clock input)
TSYN (-) (Sync input)
TXD (-) (DPS data output)
RXD (-) (DPS data input)
RSYN (-)
RCLK (-)
N/C
N/C
TCLK (+)
TSYN (+)
TXD (+) (DPS data output)
RXD (+) (DPS data input)
RSYN (+)
RCLK (+)
N/C
Fuse alarm
-BATT
GND
FRAME
Power
Back View
These ports not used in this application
Terminal Package
D-PC-413-11C-04
3-30-99
Front View
Block
Diagram
DB15 Female
DB25 Female
DB9 Male
DB15 Female
DB9 Female
1
8
9
15
1
8
9
15
Section A
Section B
Data
Network
1
12
13
25
AD
PCM
1
1
5
5
6
6
9
9
VF
DPS Telecom
DPC-64
DPS INC.
FA
MOD
8
7
5
6
DVF-64
DPS Telecom
FA
Section A
Section B
DVF-64
64 Kbit to Fiber Network A
64 Kbit to Fiber Network B
32 Kbit E2A ports
(202 Modem/VF)
24 Kbit Order-Wire
port (to ADPCM in
future order-wire shelf)
8 Kbit TABS ports
(RS422)
1 2 3 4 5 6 7 8 9 10
31 32 33 34 35 36 37 38 39 40
21 22 23 24 25 26 27 28 29 30
51 52 53 54 55 56 57 58 59 60
ALM
RTN
ALM
RTN
ALM
RTN
ALM
RTN
ALM
RTN
ALM
RTN
C1
C2
C3
Connectors are wired
for future KDA 864-TABS network element.
E2A/202 Modem
Connections
Fuse alarm
T
R
T
R
1
1
Shield
1 2 3 4 5 6 7 8 9 10
TABS RS422
Connections
A B A
Wire-Wrap
Block C3
Details
B
Alarm
points
61-63
Control
points
1-8
Jumpers are factory
installed for
KDA 864-TABS*
application.
*To convert to KDA 864 E2A application,
remove jumpers and re-jumper
pin 7A to 9C, 7B to 9D,
7C to 9A and 7D to 9B.
**To convert to FDO 3000 Off-Net application,
remove jumpers and re-jumper pin 1C to 2C
and 1D to 2D.
2W**
POTS line
Fig. 8 - Terminal package is wired to accept KDA network element or FDO 3000 Off-Net plug-in card.
Содержание D-PG-413-11C-00
Страница 6: ...6 7...