F
RONT
P
ANEL
P
USH
S
WITCH
The front panel push switch is used to control several features:
#
Five Second Manual Video Switching
#
Long Duration Manual Video Switching
#
Low Voltage Alert Silence
#
System Configuration Programming
F
IVE
S
ECOND
M
ANUAL
V
IDEO
S
WITCHING
During normal operation the video source can be manually switched by briefly (less than
½ second) pressing the pushbutton switch. The automatic video switching is disabled for
five seconds to allow temporary viewing of a noisy video source. Normal video switching
will be restored after the 5-sec delay.
L
ONG
D
URATION
M
ANUAL
V
IDEO
S
WITCHING
If the five second timer is not wanted during Manual Video Switching then it can be
disabled by pressing the pushbutton switch for more than three seconds. A confirmation
beep will be heard and the Green Status LED will slowly blink as a warning that the
Manual switching mode is enabled. To cycle to a different RX source simply tap the
pushbutton switch.
The manual switching mode will revert back to normal operation after the pushbutton
switch is pressed for two seconds (or power is removed). This feature is a toggle
operation and can be used whenever you want to disable or enable the automatic video
switching.
L
OW
V
OLTAGE
A
LERT
A periodic beep warning will be heard if the low voltage alert has been enabled and the
battery voltage is too low. The S
TATUS
LED will also change to a Red color and blink at a
fast rate.
The voltage alert’s beep sound can be silenced by pressing the pushbutton switch for
more than one second. The threshold for low voltage detection is a user setting and must
be configured to match the end-of-charge voltage condition requirements for your battery.
S
YSTEM
C
ONFIGURATION
P
ROGRAMMING
Diversity Demon must be configured for your particular application. Please see the next
section for system programming instructions.