Argon Distributors Warranty Policy for Davies Pumps
Your Davies Pump, when used for its designed purpose should give you years of trouble free service. Please
take the time to read and understand the operator’s manual for this pump before installing and running your
pump. Failure to install and operate as per the operation instructions will render warranty on this unit void.
Davies Pumps are warranted to be free of material and manufacturing defects at the time of purchase.
Warranty Period: 2 Years from date of purchase.
This warranty is limited to the cost of the product and does not cover travel charges, removal and reinstallation
charges, consumables, Electrician or Plumbers charges or any other third party costs unless authorized by
Argon Distributors prior to being carried out.
Argon distributors will repair or replace for the consumer any portion of the failed item which has proved
to be defective within the warranty period. Replacement product or parts may include refurbished parts or
components.
The warranty does not cover Damage or malfunction resulting from:
A. Misuse, accident, fire, water, lightning, negligence, abuse, product modifications.
B. Repairs or attempted repairs by unauthorized persons
C. Damages to product caused by transit
D. Removal or installation of the product
E. Normal wear and tear.
F. Water and Insect ingression
G. Exposure to corrosive conditions
H. Dry run
I. Foreign objects in the liquid being pumped
J. Electrical power fluctuations
K. Freight
Argon Distributors liability is limited to the cost of the product and shall not be liable for:
A. Damage to other property caused by defects in the product.
B. Loss of use of the product.
C. Loss of time, loss of profits, loss of business opportunity, loss of goodwill
D. Any other damages‐incidental, consequential or otherwise.
E. Claims under this warranty must give evidence of the Date of purchase, Invoice Copy, Model, Serial Num-
ber, photos and information of the installation as soon as the failure has occurred. Owner’s details must be
noted.
If any of the above is unclear please contact the warranty manager at:
ARGON DISTRIBUTORS Freephone: 0508 634 341
Problem
Cause
Remedy
Pump doesn’t run
* Power supply is not connected
* Check the fuse or the power supply
* Capacitor is damaged
* Bearing blocked while the
pump is attempting to run
* Replace capacitor
* Run it at a higher speed shortly or rotate the
shaft by inserting a screwdriver into the slot at
the motor shaft end
* There are impurities in pump
* Disconnect power and clean the pump
Noise in the system * The flow is too high
* Air in the pump
* Run at a slower speed
* Vent the pump
Noise in the pump
* Air in the pump
* The inlet pressure is too low
* Vent the pump