![Doyon JA8X Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/doyon/ja8x/ja8x_manual_2525329013.webp)
A-9
JA8X & JA8XR Operation & installation manual.doc 04/19
FAN OFF DELAY FUNCTION
By pressing on the FAN OFF DELAY icon, the fan remains OFF for a period of 1, 3 or 5 minutes, if 3 minutes is
selected and after period of time it is change to 5 minutes, it will be 5 minutes total not 8 minutes. The control will
deduct the time from the 3 minutes already use to get total of 5 minutes delay.
To cancel fan off delay, press the FAN OFF DELAY icon, until see
.
STEAM FUNCTION
Steam volume is calibrated with the oven cavity temperature, so the amount of water that generate steam will vary with
the oven cavity temperature.
○
Pressing PULSE STEAM icon, the icon logo will turn Green and the shot steam icon will hide during the
pulse is in function, this will create continuous steam injections every 30 second interval to create moisture
in the cavity during baking. If pressed the icon again, it will cancel the pulse steam function.
○
Pressing SHOT STEAM icon, the icon logo will turn green and a single steam injection will inject a preset
calibrate volume of water with oven cavity temperature. Following the steam injection you will have
automatically a FAN OFF DELAY of 30 seconds. If pressed the icon again before end of the shot steam, it
will cancel the shot steam function.
FAN SPEED FUNCTION
You can change the fan speeds. There are 3 different fan speed setting available LOW, MEDIUM and HIGH, Default
speed is HIGH To select a different fan speed press the fan speed icon to select desire fan speed. This function will
creating a different air flow.
FAN REVERSING CYCLE FUNCTION PRESET TIME
4 different Default fan reversing cycles setting available 1 (2.5 min ON - 10 sec. OFF), 2 (1.5 min ON - 25 sec OFF),
3 (1:30 min ON – n o OFF delay) and 4 (1:00 min ON – n o OFF delay). Default fan reversing cycle is 1. To select
a different fan reversing cycle then 1, press the fan reversing cycle icon to select desired fan reversing cycle time.
This function will change the fan reversing time cycle, creating a different air flow volume during the baking.
POWER VENT FUNCTION
This function will rapidly in +/- 10second exhaust steam in the cavity to bake in dry condition or cooldown oven
temperature faster this function need to be cancel manually in manual function mode.