2530GA(P)
- 41 -
03.27603.000
Access to the most important components
•
Open the front door. Unscrew the little locking bolt of the hinge first.
•
Remove the loose log retainer.
•
The
pilot flame
is visible in front of the combustion chamber and is very
easily accessible.
•
Remove the loose coals and matrixes or logs and the back mrror.
•
The
main burner
can now be lifted from its seat and removed.
•
The
main injector
is visible on the bottom of the combustion chamber.
If required, after disconnecting the
gas connection
electrical plug connection
connection cable with the TTB
the gas unit (gas block, pipework, main injection valve, pilot, fan) can be com-
pletely removed from the appliance, after the two screws at the bottom of the
combustion chamber have been removed.
In the event that the fan needs to be replaced, make sure that the connections
are correct (see number indication). .