Dovre 2300GL Скачать руководство пользователя страница 10

2300  - 2400

                                                        10                                                  

03.27997.000

 

Convection chamber: 

The convection chamber topside must be airtight. For that purpose, you can use a 
cover of steel, concrete, or any other fire-resistant material, and put extra insulation 
on top of it. Make sure that the cover is well horizontally placed.  
The cover must be installed at 30 cm at least above the smoke dome. The outlet 
grids (optional) must be installed straight under that cover. Make sure that convec-
tion outlet area is big enough: minimum 500 cm².  
In the convection chamber no combustible material must be used. Make sure that, 
when using other auxiliary material such as steel, it will not function as a heat 
bridge.  
The picture on the next page shows an example of fireplace installation within com-
bustible material.   

3.4.       Finishing 

When the appliance is installed in the right place, its connection with the chimney 
made airtight, and the masonry mantle completely mounted, all loose parts are in-
stalled in the appliance.   
Your fireplace is now ready to be used.  
Depending on the materials used for mounting, it is recomme nded to wait for some 
time until all masonry is dry before lighting a fire. 

Attention: never light a fire with the inner plates or refractory stones removed. 

3.5.       Packaging materials 

Packaging materials should be disposed of in a responsible way and in accordance 
with governmental regulations. 

Содержание 2300GL

Страница 1: ...LLATIEVOORSCHRIFTEN EN GEBRUIKSAANWIJZING INSTALLATION ET MODE D EMPLOI INSTALLATION INSTRUCTIONS AND OPERATING MANUAL EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG INBOUWHAARD FOYER FIREPLACE KAMINEINSATZ 2...

Страница 2: ...removal 38 4 6 Extinguishing the fire 38 4 7 Weather conditions 39 5 Maintenance 39 Annex 1 Technical data sheet 52 Annex 2 Dimensions 53 Inhalt pag Vorwort 40 1 Einleitung 40 2 Sicherheit 40 3 Montag...

Страница 3: ...ioning chimney and sufficiently ventilated you can take the long term and trouble free functioning of your heater for granted Please consult an expert when installing and connecting the heater The man...

Страница 4: ...raught is caused by environmental phenomena such as wind It is prohibited to connect several heaters to one chimney for instance the central heating boiler unless local or national regulations allow t...

Страница 5: ...rupt the combustion process and cause the smoke flow through the chimney to be interrupted which may lead to smoke emissions into the room Mainly in case of a fireplace together with the combustion ga...

Страница 6: ...ly pro tected The floor under the fireplace and the walls around it must not contain electric wires Under the appliance Under the appliance any combustible material must be removed or specially shield...

Страница 7: ...ust the height of the leg on the holder with bolt M8x50 nut M8 and both collars 8x 25 Fix the adjustment bolts under the legs These will allow to adjust the fireplace level 3 1 4 Combustible material...

Страница 8: ...d either horizon tally or vertically Fix the flue collar on the smoke dome with 2 bolts M6x30 2 nuts M6 and 4 collars 6x 12 Assure proper sealing with kit or paste 3 2 3 Installation of the ashtray if...

Страница 9: ...opening is 250 cm The grids may be installed on all sides It is important that air flows freely into the convection chamber If you use an air vent to convey outside air into the convection chamber rem...

Страница 10: ...g other auxiliary material such as steel it will not function as a heat bridge The picture on the next page shows an example of fireplace installation within com bustible material 3 4 Finishing When t...

Страница 11: ...ble wall Convection area Fresh air inlet Fireproof floor Combustible floor Convection air inlet Insulation if necessary Convection Air outlet Opening against eventual pressu re buildup Stainless steel...

Страница 12: ...than twenty pe r cent moisture Wet logs are unsuitable for burning as they do not produce enough heat and all of the energy is lost in the process of evaporation Moreover the burning of wet wood caus...

Страница 13: ...cause tar and creosote to deposit in the chimney after a long pe riod of time Tar and creosote are highly combustible substances Thicker layers of these substances might catch fire when the t emperat...

Страница 14: ...he glass can be cleaned with a number of glass cleaning products available on the market Your installer can also supply you with appropriate products However never use abrasive or corrosive cleaning p...

Страница 15: ...al length of logs Maximal L nge der Holzblocken 40 cm 40 cm Schoorsteenaansluiting diameter Raccordemant chemin e diam tre Flue connection diametre Schornsteinanschluss Diameter 200 mm 200 mm CO 0 11...

Страница 16: ...2300 2400 16 03 27997 000 2300...

Страница 17: ...2300 2400 17 03 27997 000 2400...

Страница 18: ...ct improvement specifications of the delivered product may differ from the con tent of this booklet without further notice Im Rahmen kontinuerlicher Produktverbesserung k nnen Specifikationen des geli...

Отзывы: