background image

Operation Guide

13. Temperature Control Mode

13.1 

Temperature Control is available when using Nickel 200 coil as well as Titanium coil.

13.2 When in Nickel 200 coil temperature control mode, the device will display the 
       correct temperature with Nickel 200 coil only.
13.3 When in Titanium coil temperature control mode, the device will display the 
       correct temperature with Titanium coil only.
13.4 Nickel 200 coil and Titanium coil

 working resistance range: 0.05Ω - 1.0Ω.

13.5 Temperature control range: 200°F - 600°F/100

 - 300

℃.

13.6 When in temperature control mode, every time you put a new atomizer into 
       the Guardian 1.5 you should lock the initial resistance first before firing.
13.7 Before lock the initial resistance please ensure the Nickel coil or Titanium coil 
       is under ambient temperature before activating the Guardian 1.5, or it may 
       read a wrong resistance value.

Содержание Guardian 1.5

Страница 1: ......

Страница 2: ......

Страница 3: ...Size 100 0mm 57 0mm 28 5mm Material Zinc alloy and silica gel Temperature Control...

Страница 4: ...m coil 4 2 Nickel 200 coil and Titanium coil working resistance range 0 05 1 0 4 3 Temperature control range 200 F 600 F 100 300 5 Standard atomizer working resistance range 0 05 3 0 6 Short Circuit P...

Страница 5: ...ower off automatically after 60 minutes no use you need restart the device by pressing the fire button 5 times quickly to vaping again 1 ON OFF Battery Switch By pressing the fire button 5 times quick...

Страница 6: ...m right corner will display the wattage in the middle See picture 4 1 Ni 200 coil and Titanium coil is not available in this mode 4 2 When in Ni 200 coil temperature control mode if vaping with Ni 200...

Страница 7: ...e using the or button will allow you to increase or decrease desired temperature by 10F 5 Holding in either button will cause the temperature to increase or decrease quickly 7 Temperature Control mode...

Страница 8: ...erature before activating the Guardian 1 5 There is no need to lock the initial resistance if it s a same atomizer 9 2 When in wattage mode when you put a new atomizer and press the fire button the de...

Страница 9: ...il the words STEALTH MODE appears the device switches to Stealth Mode When in Stealth Mode the screen only displays warning information or LOCKED CLICK 5X You can start stealth vaping by turning off L...

Страница 10: ...ll display the correct temperature with Titanium coil only 13 4 Nickel 200 coil and Titanium coil working resistance range 0 05 1 0 13 5 Temperature control range 200 F 600 F 100 300 13 6 When in temp...

Страница 11: ...damaged by a higher than desired temperature scenario caused by low juice volume or other reasons 14 Overtime Vaping Warning The device will force shut down by itself after 10 seconds of continuous f...

Страница 12: ...eous current 17 Overheat Protection When the mainboard s temperature is too high the device will stop working and will display DEVICE TOO HOT screen 18 The screen will display CHECK ATOMIZER if there...

Страница 13: ...200 coil Ti coil or standard coil is working in corresponding mode It is not recommended to use nickel coils or titanium coil during high wattage vaping in WATTAGE MODE This is to avoid damaging the...

Страница 14: ...REMARK Please use the battery with good insulation It is not recommended to use battery with broken insulation See picture below Picture 24 1 Picture 24 2 Operation Guide...

Страница 15: ...using your device for a long period of time please turn off the system remove the batteries and store it in a dry safe place to avoid damage 4 If something wrong happens to the products please ask a p...