Dover Wilden Original P1 Скачать руководство пользователя страница 14

12

Step 9. 

Figure 9

Lift the liquid chamber away from the center section to 
expose the diaphragm and outer piston.

Step 10. 

Figure 10

Using an adjustable wrench, or by rotating the diaphragm 
by hand, remove the diaphragm assembly from the center 
section.

Step 11A. 

Figure 11A

NOTE:  Due to varying torque values, 
one of the following two situations may 
occur: 1) The outer piston, diaphragm 
and inner piston remain attached to the 
shaft and the entire assembly can be 
removed from the center section.

Step 11B. 

Figure 11B

2) The outer piston, diaphragm, inner 
piston, and disc spring separate from 
the shaft which remains connected to 
the opposite side diaphragm assem-
bly.  PTFE-fitted pumps come standard 
with back-up diaphragms (not shown). 
NOTE: Disc spring not shown on Figure 
11B.

Step 12. 

Figure 12

To remove the diaphragm assembly 
from the shaft, secure shaft with soft 
jaws (a vise fitted with plywood or other 
suitable material) to ensure shaft is not 
nicked, scratched, or gouged. Using an 
adjustable wrench, remove diaphragm 
assembly from shaft. Inspect all parts for 
wear and replace with genuine Wilden 
parts if necessary.

WILDEN PUMP & ENGINEERING, LLC

WIL-10140-E-08

S e c t i o n   7

D I S A S S E M B L Y / R E A S S E M B L Y

Содержание Wilden Original P1

Страница 1: ...W h e r e I n n o v a t i o n F l o w s www wildenpump com P1 Original Series PLASTIC Pumps EOM Engineering Operation Maintenance WIL 10140 E 08 REPLACES WIL 10140 E 07 ...

Страница 2: ...CTION 4 DIMENSIONAL DRAWINGS 4 SECTION 5 PERFORMANCE A P1 Plastic Rubber Fitted 5 P1 Plastic TPE Fitted 5 P1 Plastic PTFE Fitted 6 B Suction Lift Curves 6 SECTION 6 SUGGESTED INSTALLATION OPERATION TROUBLESHOOTING 7 SECTION 7 ASSEMBLY DISASSEMBLY 10 SECTION 8 EXPLODED VIEW PARTS LISTING P1 Plastic Rubber Fitted 20 PTFE Fitted 22 SECTION 9 ELASTOMER OPTIONS 24 ...

Страница 3: ...aintenance or repair is attempted the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from pump Disconnect all intake discharge and air lines Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container CAUTION Blow out air line for 10 to 20 seconds before attaching to pump to make sure all pipe line debris is clear ...

Страница 4: ...ed hardware female connections 0522 Ultrapure II male bondable connections 0523 Ultrapure II PFA coated hardware male bondable connections 0524 Ultrapure II Wil Gard II 110V male bondable connections 0525 Ultrapure II female connections PFA coated hardware Wil Gard II sensor wires ONLY 0530 Ultrapure II Wil Gard II 110V female connections 0531 Ultrapure II female connections Wil Gard II sensor wir...

Страница 5: ... valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center block of the pump creates a vacuum within liquid chamber A Atmospheric pressure forces fluid into the inlet manifold of the pump The inlet valve ball is forced off its seat allowing the fluid being pumped to fill the...

Страница 6: ...1 1 2 B 130 5 1 C 196 7 7 D 208 8 2 E 218 8 6 F 56 2 2 G 114 4 5 H 127 5 0 J 203 8 0 K 145 5 7 L 114 4 5 M 84 3 3 N 102 4 0 P 8 0 3 R 20 0 8 S 28 1 1 WILDEN PUMP ENGINEERING LLC WIL 10140 E 08 S e c t i o n 4 D I M E N S I O N A L D R A W I N G S ...

Страница 7: ... center of the pump performance curve Height 218 mm 8 6 Width 208 mm 8 2 Depth 203 mm 8 0 Est Ship Weight Polypropylene 4 kg 9 lbs PVDF 5 kg 11 lbs PTFE PFA 6 kg 12 lbs Air Inlet 6 mm 1 4 Inlet 13 mm 1 2 Outlet 13 mm 1 2 Suction Lift 5 8 m Dry 19 9 8 m Wet 32 Displacement per Stroke 0 11 l 0 030 gal 1 Max Flow Rate 56 8 lpm 15 gpm Max Size Solids 1 6 mm 1 16 1 Displacement per stroke was calculate...

Страница 8: ...25 psig air supply pressure Flow rates indicated on chart were determined by pumping water For optimum life and performance pumps should be specified so that daily operation parameters will fall in the center of the pump performance curve WILDEN PUMP ENGINEERING LLC WIL 10140 E 08 P1 PLASTIC PTFE FITTED S e c t i o n 4 P E R F O R M A N C E P 1 P L A S T I C S U C T I O N L I F T C A PA B I L I T ...

Страница 9: ...ility will assure that loss of prime troubles will be eliminated In addition pump efficiency can be adversely affected if proper attention is not given to site location PIPING Final determination of the pump site should not be made until the piping problems of each possible location have been evaluated The impact of current and future installations should be considered ahead of time to make sure t...

Страница 10: ...ting and preventing future maintenance problems and unscheduled downtime In addition accurate records make it possible to identify pumps that are poorly suited to their applications MAINTENANCE AND INSPECTIONS Since each applica tion is unique maintenance schedules may be different for every pump Frequency of use line pressure viscosity and abrasiveness of process fluid all affect the parts life o...

Страница 11: ... 1 Check for pump cavitation slow pump speed down to allow thick material to flow into the liquid chambers 2 Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped cavita tion 3 Check for sticking ball check valves If material being pumped is not compatible with pump elastomers swell ing may occur Replace ball check valves and seals with prop...

Страница 12: ...lded of polypropylene or acetal All fasteners and hardware are stainless steel and the air valve is manufactured of brass or high tech engineered thermoplastic Its air distribution system is based on a revolutionary design which offers economical reliability and performance The model P1 Plastic is available in injection molded polypropylene PVDF and PTFE PFA wet ted parts TOOLS REQUIRED 8 mm 5 16 ...

Страница 13: ...n parts with genuine Wilden parts for reliable perfor mance PTFE o rings should be replaced when reassem bled Step 6 Figure 6 Normally the inlet and discharge mani fold should not be disassembled during regular pump maintenance Should this be necessary completely remove and disassemble manifold clamp bands Step 7 Figure 7 Inspect o rings for wear or damage and replace if necessary PTFE o rings sho...

Страница 14: ...re 11B 2 The outer piston diaphragm inner piston and disc spring separate from the shaft which remains connected to the opposite side diaphragm assem bly PTFE fitted pumps come standard with back up diaphragms not shown NOTE Disc spring not shown on Figure 11B Step 12 Figure 12 To remove the diaphragm assembly from the shaft secure shaft with soft jaws a vise fitted with plywood or other suitable ...

Страница 15: ...E encapsulated Viton on the UPII The standard air distribution system is used on the UPII All o rings used in the pump are of a special material and should only be replaced with Wilden factory supplied parts Tools required to perform maintenance on the Model P1 pump are 3 16 inch 5 16 inch and 9 16 inch Allen wrench 7 16 inch wrench two open end adjustable wrenches and an o ring pick PLEASE read a...

Страница 16: ...ng or other damage is apparent these parts must be replaced Step 4 Figure 4 Loosen and remove clamp bands from around the inlet manifold Step 5 Figure 5 Lift center section off of the inlet mani fold It is now possible to inspect the outboard o rings on the inlet manifold Step 6 Figure 6 Place center section upside down on a flat surface Remove the o ring seat and valve ball from the bottom of the...

Страница 17: ...ed from the pump Disconnect all intake discharge and air lines Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container Be aware of hazardous effects of contact with your process fluid The Wilden Plastic P1 utilizes a revolutionary Pro Flo air distribution system A 13 mm 1 2 air inlet connects the air supply to the center section Proprietary composite seals...

Страница 18: ...OTE Seals should not be removed from pilot spool Seals are not sold separately Step 9 Figure 9 Check center section Glyd rings for signs of wear If necessary remove Glyd rings with o ring pick and replace Step 5 Figure 5 Remove air valve spool from air valve body by threading one air valve bolt into the end of the spool and gently sliding the spool out of the air valve body Inspect seals for signs...

Страница 19: ... a flat surface prior to tightening their clamp bands to the desired torque see this page for torque specs Be sure to tighten outer pistons simultaneously on PTFE fitted pumps to ensure proper torque values Ensure proper mating of liquid chambers to manifolds prior to tightening vertical bolts Overhang should be equal on both sides Apply a small amount of Loctite 242 to the shaft interval threads ...

Страница 20: ...all sealing surfaces P1 Poly pumps come standard with expanded PTFE Gasket Kits P N 01 9500 99 for diaphragm bead only Carefully prepare sealing surfaces by removing all debris and foreign matter from diaphragm bead and all mating surfaces If necessary smooth or deburr all sealing surfaces Mating surfaces must be properly aligned in order to ensure positive sealing characteristics Step 4 Figure 4 ...

Страница 21: ...S e c t i o n 5 N O T E S ...

Страница 22: ...20 WILDEN PUMP ENGINEERING LLC WIL 10140 E 08 S e c t i o n 8 E X P L O D E D V I E W P A R T S L I S T I N G P1 PLASTIC Rubber Fitted E X P L O D E D V I E W ...

Страница 23: ...500 19 Liquid Chamber 2 01 5000 20 01 5000 21 20 Manifold Tee Section 2 01 5160 20 01 5160 21 21 Inlet Manifold Elbow 2 01 5220 20 01 5220 21 22 Discharge Manifold Elbow 2 01 5230 20 01 5230 21 23 Screw SHCS Chamber Bolt 4 01 6080 03 01 6080 03 24 Vertical Bolt Washer 4 01 6730 03 01 6730 03 25 Vertical Bolt Nut 4 04 6400 03 04 6400 03 26 Diaphragm 2 27 Valve Ball 4 28 Valve Seat 4 01 1120 21 500 ...

Страница 24: ...22 WILDEN PUMP ENGINEERING LLC WIL 10140 E 08 S e c t i o n 8 E X P L O D E D V I E W P A R T S L I S T I N G P1 PLASTIC PTFE Fitted E X P L O D E D V I E W 36 35 ...

Страница 25: ...0 01 5160 20 01 5160 21 01 5160 21 01 5160 22 21 Inlet Manifold Elbow 2 01 5220 20 01 5220 20 01 5220 21 01 5220 21 01 5220 22 22 Discharge Manifold Elbow 2 01 5230 20 01 5230 20 01 5230 21 01 5230 21 01 5230 22 23 Screw SHCS Chamber Bolt 4 01 6080 03 01 6080 05 01 6080 03 01 6080 05 01 6080 05 24 Vertical Bolt Washer 4 01 6730 03 01 6730 05 01 6730 03 01 6730 05 01 6730 05 25 Vertical Bolt Nut 4 ...

Страница 26: ...flex 01 1010 56 01 1080 56 N A 01 1200 56 01 1300 56 PTFE3 01 1010 55 01 1080 55 N A N A PTFE with integral piston 01 1030 55 N A N A N A N A PVDF N A N A 01 1120 21 500 N A N A PTFE Encapsulated Viton N A N A N A 01 1205 60 01 1300 60 500 1Must be used with part number 01 5010 21 500 PTFE diaphragms require Neoprene back up diaphragms P N 01 1060 51 P1 Ultrapure pump series require high temp Buna...

Страница 27: ...comes first Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump and Engineering LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any...

Страница 28: ...up PSG ADoverCompany PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document 08 2014 A u t h o r i z e d P S G R e p r e s e n t a t i v e Where Innovation Flows 22069 Van Buren St Grand Terrace CA 92313 5607 T 1 909 422 1731 F 1 909 783 3440 ...

Отзывы: