![Dover Wilden Original A4 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/dover/wilden-original-a4/wilden-original-a4_engineering-operation-and-maintenance_2525072008.webp)
6
WILDEN PUMP & ENGINEERING, LLC
WIL-10260-E-02
SECTION 5A
PERFORMANCE CURVES
T4 METAL RUBBER-FITTED
Height .................................. 442 mm (17.4")
Width ................................... 391 mm (15.4")
Depth .................................. 285 mm (11.2")
Est. Ship Weight ..........Aluminum 17 kg (38 lbs)
Stainless Steel 26 kg (57 lbs)
Cast Iron 26 kg (57 lbs)
Air Inlet ....................................13 mm (1/2")
Inlet ..................................... 38 mm (1-1/2")
Outlet .................................. 32 mm (1-1/4")
Suction Lift ................................5.49 m (18')
8.53 m (28')
Displacement per
Stroke ......................... 1.02 l (0.27 gal.)
1
Max. Flow Rate ................. 288 lpm (76 gpm)
Max. Size Solids ...................4.8 mm (3/16")
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example:
To pump 113.6 lpm (30 gpm)
against a discharge pressure head of 2.7
bar (40 psig) requires 4.1 bar (60 psig) and
25.5 Nm
3
/h (15 scfm) air consumption. (See
dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
[LPM]
Water Discharge Flow Rates
SECTION 5B
PERFORMANCE CURVES
T4 METAL ULTRA-FLEX™-FITTED
Height .................................. 452 mm (17.4")
Width ................................... 391 mm (15.4")
Depth .................................. 285 mm (11.2")
Est. Ship Weight ..........Aluminum 17 kg (38 lbs)
Stainless Steel 26 kg (57 lbs)
Cast Iron 26 kg (57 lbs)
Air Inlet ....................................13 mm (1/2")
Inlet ..................................... 38 mm (1-1/2")
Outlet .................................. 32 mm (1-1/4")
Suction Lift ......................... 4.88 m Dry (16')
8.23 m Wet (27')
Displacement per
Stroke ........................... 0.68 l (0.18 gal.)
1
Max. Flow Rate ................ 235 lpm (62 gpm)
Max. Size Solids ...................4.8 mm (3/16")
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example:
To pump 94.6 lpm (25 gpm)
against a discharge pressure head of 2.7
bar (40 psig) requires 4 bar (60 psig) and 34
Nm
3
/h (20 scfm) air consumption. (See dot
on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air
supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
[LPM]
Water Discharge Flow Rates