Step 11.

Figure 11

Lift the liquid piston away from the
power piston.

Step 12.

Figure 12

Inspect the power piston O-rings for nicks,
gouges, chemical attack or abrasive wear.
Replace worn parts if necessary.

Step 13.

Figure 13

Inspect the liquid piston bore cup seals
for nicks, gouges, chemical attack or
abrasive wear.

Step 14.

Figure 14

If the cup seals are damaged and need
to be replaced, install new cup seals.
When installing new cup seals, cup side
of both seals should face away from one-
another. The cup on the inner cup seal
should face towards the bolt flange on
the liquid chamber. The cup on the outer
cup seal should face towards the valve
ball area of the liquid chamber.

Step 15.

Figure 15

To inspect or replace the discharge
manifold O-ring, valve seat O-ring, valve
seat, valve ball and ball cage, first
remove the combo manifold plate located
at the top of the liquid chamber. 
To inspect or replace the inlet manifold
O-ring, valve seat O-ring, valve seat,
valve ball and ball cage, repeat process.  

Step 16.

Figure 16

With the combo manifold plate removed,
the manifold O-ring, valve seat O-ring,
valve seat, valve ball and ball cage can
be inspected for nicks, gouges, chemical
attack or abrasive wear.  Repeat process
at inlet manifold plate.  Replace worn
parts with genuine Wilden parts for
reliable performance.

Inner

Cup Seal

Cup area
of seal

Outer

Cup Seal

Содержание Wilden Advanced H25

Страница 1: ...High Pressure H25 WIL 11180 E 02 Replaces EOM Rhino 1600S 8 03 EOM E n g i n e e r i n g O p e r a t i o n M a i n t e n a n c e Advanced Series METAL Pumps A d v a n c e y o u r p r o c e s s...

Страница 2: ...ation Wetted Path 7 C Installation Remote Solenoid 7 D Operation Maintenance 8 E Installation Electrical Connections 8 F Troubleshooting 9 SECTION 7 DIRECTIONS FOR DISASSEMBLY REASSEMBLY A Model H25 1...

Страница 3: ...COVER A ALUMINUM VALVE SEATS S STAINLESS STEEL VALVE SEAT O RINGS BN BUNA N SPECIALTY CODES 150 24V DC COIL 151 24V AC COIL 153 24V AC NEMA 7 COIL 154 24V DC NEMA 7 COIL 155 110V AC COIL 156 110V AC...

Страница 4: ...ber creates a vacuum within the wetted portion of the pump atmospheric pressure on the inlet fluid forces the inlet valve ball off its seat and allows the fluid being pumped to fill the liquid chamber...

Страница 5: ...Pump valves and containers must be grounded to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard CAUTION Do not exceed 8 6 bar 125 psig a...

Страница 6: ...nch A 188 7 4 B 86 3 4 C 20 0 8 D 236 9 3 E 183 7 2 F 28 1 1 G 188 7 4 H 13 0 5 J 150 5 9 K 10 0 4 SECTION 4 DIMENSIONAL DRAWING WILDEN MODEL H25 1600S PUMP 6 mm 1 4 FNPT DISCHARGE 10 mm 3 8 FNPT AIR...

Страница 7: ...utlet 6 mm Suction Lift 7 8 m Dry 25 5 9 2 m Wet 30 1 Max Flow Rate 4 1 lpm 1 1 gpm Example To pump 2 6 lpm 0 7 gpm against a discharge head of 20 7 bar 300 psig requires 4 1 bar 60 psig and 20 4 Nm3...

Страница 8: ...out routine inspections and adjustments Should major repairs become necessary ease of access can play a key role in speeding the repair process and reducing total downtime AIR SUPPLY Every pump locat...

Страница 9: ...23 includes 20 of nylon tubing NOTE For electrical connections see Section 6E SECTION 6B SUGGESTED INSTALLATION WETTED PATH SECTION 6C SUGGESTED INSTALLATION REMOTE SOLENOID PRESSURE GAUGE SHUT OFF VA...

Страница 10: ...best means for preventing unscheduled pump downtime Personnel familiar with the pump s construction and service should be informed of any abnormalities that are detected during operation RECORDS When...

Страница 11: ...ric signal is slow enough that the pump is able to complete each physical stroke before it is signaled to change direction The time required to complete the stroke is determined by a variety of factor...

Страница 12: ...ardous effects associated with contact with your process fluid The H25 1600S metal pump has a 13 mm inlet and 6 mm outlet and is designed for flows up to 4 1 lpm 1 1 gpm The H25 1600S is available wit...

Страница 13: ...ce the liquid chamber onto a table or sturdy flat surface Next with the liquid chamber resting on the bolted flange apply 1 0 bar 15 psig of air pressure via a rubber tipped air nozzle into the brass...

Страница 14: ...hamber The cup on the outer cup seal should face towards the valve ball area of the liquid chamber Step 15 Figure 15 To inspect or replace the discharge manifold O ring valve seat O ring valve seat va...

Страница 15: ...amount of Loctite 242 to the power liquid bolt threads If air continually blows out the exhaust in very large quantities it is possible that it may be saved by completely disassembling the valve clean...

Страница 16: ...5 6 2 3 4 1 13 15 14 7 11 10 9 22 21 20 19 18 16 23 12 8 17 24 24 SECTION 8 EXPLODED VIEW PARTS LISTING H25 1600S...

Страница 17: ...luded with purchase of pump All boldface items are primary wear parts Specialty Code Part Number Description 150 95 2000 99 150 24V DC Valve Assembly 151 95 2000 99 151 24V AC 12V DC Valve Assembly 15...

Страница 18: ...99 155 60 120 110 4 8 08 08 06 840 NEMA 7 UL CSA Voltage 10 Current A AC AC DC Power W DC Resistivity Part Number 60 Hz 50 Hz 10 Inrush Holding 1 00 2110 99 153 12 24 22 7 60 55 32 19 00 2110 99 154 2...

Страница 19: ...TT5178...

Отзывы: