GREER COMPANY
Crane Systems
26 of 35
OPERATOR SETTABLE ALARMS
CONTINUED
MI N ANGLE OFF
MAX LENGTH 58. 0
MAX HEI GHT 78. 0
TEST
MAX
SET
MAX ANGLE OFF
6
23,500
i2,300
44.8
62.7
26.4
24
25
5
27
SETTING MAXIMUM BOOM
LENGTH ALARM
SETTING MAXIMUM TIP
HEIGHT ALARM
1.
Move the boom to the desired maximum
length, in this example 58 ft.
1.
Move the boom to the desired maximum
height, in this example 78 ft.
2.
Press
the
OPERATOR ALARM PUSH
BUTTON (ITEM 24)
to access the
operator alarm screen.
2.
Press
the
OPERATOR ALARM PUSH
BUTTON (ITEM 24
) to access the operator
alarm screen.
3.
Press
the
PUSH BUTTON (ITEM 25)
next to
Max Length. In this example the display will
read
MAX LENGTH 58 FT
.
3.
Press
the
PUSH BUTTON (ITEM 27)
next to Max Height. In this example the dis-
play will read
MAX HEIGHT 78 FT
.
The
RED WARNING LIGHT (ITEM 5)
will flash
and the audible alarm will sound whenever the
boom length exceeds 58 ft.
The
RED WARNING LIGHT (ITEM 5)
will flash
and the audible alarm will sound whenever the
boom tip height exceeds 78 ft.
Pressing the
MAX LENGTH PUSH
BUTTON
again will cancel the alarm and the
display will read:
MAX LENGTH OFF.
Pressing the
MAX HEIGHT PUSH BUTTON
again will cancel the alarm and the display will
read:
MAX HEIGHT OFF
.