GREER COMPANY
Crane Systems
22 of 35
CANCEL AUDIBLE ALARM
TEST
MAX
SET
6
23,500
i2,300
44.8
62.7
26.4
23
ORs Ful l
9. 7Kl b Ct wt
ERECTED 60' TELEJ I B 17 AUXHD ON
PI CK FROM MAI N BOOM
FRONT WI NCH
360
o
o
PUSH BUTTON TO CANCEL AUDIBLE ALARM
The
CANCEL ALARM PUSH BUTTON
(ITEM 23)
is used to silence the audible
alarm.
Pressing this button once will
cancel an audible alarm that has
occurred
as a result of an:
The
CANCEL ALARM PUSH BUTTON
is
also used to reset the function kick-out relay
when it is necessary to bypass the function
disconnects. See page 23.
Examples of when it may be necessary to
override a function disconnect condition are:
Overload
A2B
Alarm
If the boom hoist cylinder is fully extended,
the pressure in it will rise. This will be seen
by the system as an overload and will not
allow the operator to boom down. Using the
bypass is necessary in this situation to move
away from the fully extended boom hoist
cylinder position.
Operator Settable Alarm
The audible alarm remains canceled until
the condition that caused the alarm
has been removed.
If a new alarm condition occurs that normally
causes an alarm to sound (such as A2B) or
if a previous condition (such as overload) is
removed and then recurs, the new alarm
condition will cause the audible alarm
to sound again.