WIL-11251-E-03
10
P800 Bolted Plastic
P800 PLASTIC
FULL-STROKE
PTFE-FITTED
Ship Weights.……Polypropylene 32 kg (70 lb)
PVDF 45 kg (99 lb)
Air Inlet…………..………………..13 mm (1/2")
Inlet…...……………...………………51 mm (2")
Outlet………………...………………51 mm (2")
Suction Lift….………………..5.9 m Dry (19.5’)
9.0 m Wet (29.5’)
Disp. per Stroke
1
….…..............2.5 L (0.67 gal)
Max. Flow Rate……………615 lpm (162 gpm)
Max. Size Solids……………......6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2.1 bar
(30 psig) head pressure.
Example:
To pump 371 lpm (98 gpm)
against a discharge head of 2.8 bar
(40 psig) requires 5.5 bar (80 psig)
and 147.9 Nm
3
/h (92 scfm) air consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
P800 PLASTIC
REDUCED-STROKE
PTFE-FITTED
Ship Weights.……Polypropylene 32 kg (70 lb)
PVDF 45 kg (99 lb)
Air Inlet…………..………………..13 mm (1/2")
Inlet…...……………...………………51 mm (2")
Outlet………………...………………51 mm (2")
Suction Lift….……………..4.15 m Dry (18.16’)
8.65 m Wet (28.4’)
Disp. per Stroke
1
….…..........1.73 L (0.457 gal)
Max. Flow Rate……………504 lpm (133 gpm)
Max. Size Solids……………......6.4 mm (1/4")
1
Displacement per stroke was calculated at 4.8
bar (70 psig) air inlet pressure against a 2 bar (30
psig) head pressure.
Example:
To pump 220 lpm (58 gpm)
against a discharge head pressure
of 3.4 bar (50 psig) requires 5.5 bar (80 psig)
and 128 Nm
3
/h (75 scfm) air consumption.
Flow rates indicated on chart were determined by pumping water. For optimum life and performance, pumps
should be specified so that daily operation parameters will fall in the center of the pump's performance curve.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
PERFORMANCE
Содержание PSG Wilden Pro-Flo P800 Series