WIL-11070-E-16
15
P200 Bolted Plastic
SECTION 7
PUMP DISASSEMBLY
Tools Required:
1/2" Box Wrench
2 - 1" Socket or Adjustable Wrench
Adjustable Wrench
Vise equipped with soft jaws
(such as plywood, plastic or other
suitable material)
CAUTION:
Before attempting any maintenance or repair, disconnect the compressed
air line to the pump and allow all air pressure to bleed from the pump. Disconnect all
intake, discharge, and air lines. Drain the pump by turning it upside down and allowing
any fluid to flow into a suitable container. Be aware of any hazardous effects of contact
with your process fluid.
NOTE:
The model used for these instructions incorporates PTFE diaphragms and balls.
Models with rubber diaphragms and balls are the same except where noted.
NOTE:
Replace worn parts with genuine Wilden parts for reliable performance.
Step 1
Step 2
Step 3
Please see pre-molded alignment marks
on the liquid chamber and center section.
Using the 13 mm (1/2") box wrench,
loosen the discharge manifold from the
liquid chambers.
Using the 13 mm (1/2") box wrench,
loosen the discharge manifold from the
liquid chambers
DISASSEMBLY / REASSEMBLY