P200 Bolted Plastic 

 

SECTION 6 

Wilden pumps are designed to meet the performance requirements of 

even the most demanding pumping applications. They have been 
designed and manufactured to the highest standards and are 

available in a variety of liquid path materials to meet your chemical 
resistance needs. Refer to “Performance” for an in-depth analysis of 

the performance characteristics of your pump. Wilden offers the 
widest variety of elastomer options in the industry to satisfy 

temperature, chemical compatibility, abrasion resistance and flex 
concerns. 
 

The suction pipe size should be at least equal to or larger than the 
diameter size of the suction inlet on your Wilden pump. The suction 

hose must be a non-collapsible, reinforced type because these 
pumps are capable of pulling a high vacuum. Discharge piping should 

also be equal to or larger than the diameter of the pump discharge, 
which will help reduce friction losses. 

 

CAUTION:

 All fittings and connections must be airtight. 

Otherwise, pump suction capability will be reduced or lost. 

 
Months of careful planning, study and selection efforts can result in 

unsatisfactory pump performance if installation details are left to 
chance. You can avoid premature failure and long-term dissatisfaction 

by exercising reasonable care throughout the installation process. 
 

Location 

Noise, safety and other logistical factors usually dictate where 

equipment will be situated on the production floor. Multiple 
installations with conflicting requirements can result in congestion of 

utility areas, leaving few choices for additional pumps. 
Within the framework of these and other existing conditions, locate 
every pump in such a way that the following six key factors are 
balanced against each other to maximum advantage: 

 

Access:

 First, the location should be accessible. If it’s easy to 

reach the pump, maintenance personnel will be able to perform 
routine inspections and adjustments more easily. If major 

repairs become necessary, ease of access can play a key role 
in speeding the repair process and reducing total downtime. 

 

Air Supply:

 Every pump location should have an air line large 

enough to supply the volume of air necessary to achieve the 

desired pumping rate. For best results, the pumps should use a 
5

μ

 (micron) air filter, needle valve and regulator. The use of an 

air filter before the pump will ensure that the majority of any 
pipeline contaminants will be eliminated. 

 

Solenoid Operation:

 When operation is controlled by a 

solenoid valve in the air line, three-way valves should be used. 

This valve allows trapped air between the valve and the pump 
to bleed off, which improves pump performance. You can 

estimate pumping volume by counting the number of strokes 
per minute, and then multiplying that figure by the displacement 

per stroke. 

 

Muffler:

 Using the standard Wilden muffler, sound levels are 

reduced below OSHA specifications. You can use other mufflers 
to reduce sound levels farther, but they usually reduce pump 

performance. 

 

Elevation:

 Selecting a site that is well within the pump’s 

dynamic lift capability will assure that loss-of-prime issues will 

be eliminated. In addition, pump efficiency can be adversely 

affected if proper attention is not given to site location. 

 

Piping:

 Final determination of the pump site should not be 

made until the piping challenges of each possible location have 

been evaluated. The impact of current and future installations 
should be considered ahead of time to make sure that 
inadvertent restrictions are not created for any remaining sites. 

The best choice possible will be a site involving the shortest and 
straightest hook-up of suction and discharge piping. Unnecessary 
elbows, bends and fittings should be avoided. Pipe sizes should  

be selected to keep friction losses within practical limits. All piping 
should be supported independently of the pump. In addition,  

the piping should be aligned to avoid placing stress on the  
pump fittings. 

 
Flexible hose can be installed to aid in absorbing the forces created 

by the natural reciprocating action of the pump. If the pump is to be 
bolted down to a solid location, a mounting pad placed between the 
pump and the foundation will assist in minimizing pump vibration. 

Flexible connections between the pump and rigid piping will also 
assist in minimizing pump vibration. If quick-closing valves are 

installed at any point in the discharge system, or if pulsation within a 
system becomes a problem, a surge suppressor (SD Equalizer) 

should be installed to protect the pump, piping and gauges from 
surges and water hammer. 

 
If the pump is to be used in a self-priming application, make sure that 
all connections are airtight and that the suction lift is within the 

model’s ability. 

 

NOTE:

 Materials of construction and elastomer material 

have an effect on suction lift parameters. Please refer to 

“Performance” for specifics. 

 
When pumps are installed in applications involving flooded suction or 

suction head pressures, a gate valve should be installed in the 
suction line to permit closing of the line for pump service. 

 
Pumps in service with a positive suction head are most efficient when 

inlet pressure is limited to 0.5–0.7 bar (7–10 psig). Premature 
diaphragm failure may occur if positive suction is 0.7 bar (10 psig) 

and higher. 
 

 

CAUTION:

 All Wilden pumps are capable of passing solids. 

Use a strainer on the pump intake to ensure that the pump's 

rated solids capacity is not exceeded. 
 

CAUTION:

 Do not exceed 8.6 bar (125 psig) air  

supply pressure. 

 

CAUTION:

 Pro-Flo

®

 pumps are not submersible. 

 

 
 
 

 

 

SUGGESTED INSTALLATION, OPERATION, MAINTENANCE  

AND TROUBLESHOOTING 

Содержание PSG WILDEN PRO-FLO P200/ PKPPP 0502 Series

Страница 1: ...WIL 11070 E 16 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL P200 Bolted Plastic Pump ...

Страница 2: ... California LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are registered and unregistered trademarks of their respective owners Nothing contained in this document should be construed as granting any license or right to use any trademark without the prior written p...

Страница 3: ...tted 9 P200 Plastic TPE Fitted 9 P200 Plastic Reduced Stroke PTFE Fitted 10 P200 Plastic Full Stroke PTFE Fitted 10 Suction Lift Capability 11 SECTION 6 Suggested Installation Operation Maintenance and Troubleshooting 12 SECTION 7 Disassembly Reassembly 15 Pump Disassembly 15 Air Valve Disassembly 19 Reassembly Hints and Tips 22 Shaft Seal Installation 23 SECTION 8 Exploded View and Parts List 24 ...

Страница 4: ...ty is not exceeded CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION Do not exceed 82 C 180 F air inlet temperature for all models CAUTION The process fluid and cleaning fluids must be compatible chemically with all wetted pump components CAUTION Thoroughly flush pumps before installing them into process lines Clean and or sanitize FDA and USDA approved pumps before using them CAU...

Страница 5: ...LS BN BUNA N RED DOT FS SANIFLEX HYTREL CREAM EP EPDM BLUE DOT NE NEOPRENE GREEN DOT TF PTFE WHITE VT FKM SILVER OR WHITE DOT WF WIL FLEX SANTOPRENE THREE BLACK DOTS VALVE SEATS K PVDF P POLYPROPLYENE VALVE SEATS MANIFOLD O RING BN BUNA N TV PTFE ENCAP FKM WF WIL FLEX SANTOPRENE SPECIALTY CODES 0100 Wil Gard II 110V 0102 Wil Gard II sensor wires Only 0103 Wil Gard II 220V 0206 PFA coated hardware ...

Страница 6: ...nd manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A Atmospheric pressure forces fluid into the inlet manifold of the pump The inlet valve ball is...

Страница 7: ... 3 DIA T 115 DIA 4 5 DIA U 15 DIA 0 6 DIA ANSI FLANGE S 79 DIA 3 1 DIA T 108 DIA 4 3 DIA U 15 DIA 0 6 DIA LW0345 REV B P200 Plastic PVDF DIMENSIONS ITEM METRIC mm STANDARD inch A 452 17 8 B 66 2 6 C 257 10 1 D 376 14 8 E 429 16 9 F 99 3 9 G 104 4 1 H 122 4 8 J 257 10 1 K 288 11 3 L 353 13 9 M 310 12 2 N 124 4 9 P 157 6 2 R 10 0 4 DIN FLANGE S 84 DIA 3 3 DIA T 115 DIA 4 5 DIA U 15 DIA 0 6 DIA ANSI ...

Страница 8: ...A U 115 DIA 4 5 DIA V 14 DIA 0 6 DIA ANSI FLANGE T 79 DIA 3 1 DIA U 109 DIA 4 3 DIA V 14 DIA 0 6 DIA LW0492 REV A P200 Plastic PVDF Center Ported DIMENSIONS ITEM METRIC mm STANDARD inch A 476 18 7 B 66 2 6 C 257 10 1 D 376 14 8 E 429 16 9 F 99 3 9 G 104 4 1 H 122 4 8 J 257 10 1 K 288 11 3 L 32 1 3 M 353 13 9 N 310 12 2 P 124 4 9 R 157 6 2 S 10 0 4 DIN FLANGE T 84 DIA 3 3 DIA U 114 DIA 4 5 DIA V 15...

Страница 9: ...he pump s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure on Polypropylene and PVDF pumps P200 PLASTIC TPE FITTED Ship Weights Polypropylene 10 kg 22 lb PVDF 15 kg 32 lb Air Inlet 6 mm 1 4 Inlet 25 mm 1 Outlet 25 mm 1 Suction Lift 3 6 m Dry 11 4 9 8 m Wet 32 0 Disp per Stroke1 0 33 L 088 gal Max Flow Rate 216 lpm 57 gpm Max Size Solids 4 76 mm 3 16 1Displacement per st...

Страница 10: ...mp s performance curve Caution Do not exceed 8 6 bar 125 psig air supply pressure on Polypropylene and PVDF pumps P200 PLASTIC FULL STROKE PTFE FITTED Ship Weights Polypropylene 10 kg 22 lb PVDF 15 kg 32 lb Air Inlet 6 mm 1 4 Inlet 25 mm 1 Outlet 25 mm 1 Suction Lift 3 5 m Dry 11 4 8 6 m Wet 28 4 Disp per Stroke1 0 5 L 0 13 gal Max Flow Rate 182 lpm 48 1 gpm Max Size Solids 4 76 mm 3 16 1Displacem...

Страница 11: ...m 1 000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping fluid elevation atmospheric pressure and pipe friction loss all affect the amount of suction lift your pump will attain SUCTION LIFT CAPABILITY ...

Страница 12: ... counting the number of strokes per minute and then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other mufflers to reduce sound levels farther but they usually reduce pump performance Elevation Selecting a site that is well within the pump s dynamic lift capability will assure that lo...

Страница 13: ...sed to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss which reduces flow rate See Performance This is useful when the need exists to control the pump from a remote location When the pump discharge pressure equals or exceeds the air supply pressure the pump...

Страница 14: ... be unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped cavitation 3 Check for sticking ball check valves a If material being pumped is not compatible with pump elastomers swelling...

Страница 15: ...e down and allowing any fluid to flow into a suitable container Be aware of any hazardous effects of contact with your process fluid NOTE The model used for these instructions incorporates PTFE diaphragms and balls Models with rubber diaphragms and balls are the same except where noted NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Step 2 Step 3 Please see pre mo...

Страница 16: ...nlet manifold Remove the inlet valve balls seats and valve seat O rings from the liquid chamber and inlet manifold inspect for nicks gouges chemical attack or abrasive wear Step 7 Step 8 Step 9 Using a 13 mm 1 2 wrench remove the liquid chambers from the center section The liquid chamber should be removed to expose the diaphragm and outer piston Rotate center section and remove the opposite liquid...

Страница 17: ...ft secure shaft with soft jaws a vise fitted with plywood or other suitable material to ensure shaft is not nicked scratched or gouged Using an adjustable wrench remove diaphragm assembly from shaft Inspect all parts for wear and replace with genuine Wilden parts if necessary Inspect diaphragms outer and inner pistons for signs of wear Replace with genuine Wilden parts if necessary DISASSEMBLY REA...

Страница 18: ... Flo air distribution system A 6 mm 1 4 air inlet connects the air supply to the center section Proprietary composite seals reduce the coefficient of friction and allow the pump to run lube free Constructed of polypropylene the Pro Flo air distribution system is designed to perform in on off non freezing non stalling tough duty applications NOTE Replace worn parts with genuine Wilden parts for rel...

Страница 19: ... wear If necessary remove Glyd rings with O ring pick and replace Step 4 Step 5 Step 6 Remove air valve end cap to expose air valve spool by simply lifting up on end cap once air valve bolts are removed Remove air valve spool from air valve body by threading one air valve bolt into the end of the spool and gently sliding the spool out of the air valve body Inspect seals for signs of wear and repla...

Страница 20: ...lean the inside of the center section shaft bore to ensure no damage is done to new seals Stainless bolts should be lubed to reduce the possibility of seizing during tightening Be sure to tighten outer pistons simultaneously on PTFE fitted pumps to ensure proper torque values Apply two 2 drops of Loctite 246 to the shaft internal threads before the diaphragm assembly Concave side of disc spring in...

Страница 21: ... With the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the clamp pressure on the pliers This will allow the seal to partially snap back to its original shape 6 After removing the pliers you will notice a slight bump in the seal shape Before the seal can be resi...

Страница 22: ...WIL 11070 E 16 22 P200 Bolted Plastic SECTION 8 P200 PLASTIC LW0490 REV B ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS EXPLODED VIEW AND PARTS LIST ...

Страница 23: ...8 02 5031 21 678 17 Pipe Plug 1 1 4 NPT Center Ported Only 2 02 7012 20 02 7012 21 18 Pipe Plug 1 NPT 1 02 7013 20 19 Manifold Inlet ANSI 1 02 5090 20 02 5090 21 Manifold Inlet DIN 1 02 5091 20 02 5091 21 Manifold Inlet Center Ported NPT 1 02 5090 20 677 02 5090 21 677 Manifold Inlet Center Ported BSPT 1 02 5091 20 678 02 5091 21 678 20 Washer 344 I D x 688 O D x 065 THK 32 02 6731 03 02 6731 05 0...

Страница 24: ...0 Neoprene 02 1010 51 02 1060 51 02 1085 51 Buna N 02 1010 52 02 1085 52 04 2390 52 700 04 1300 52 500 Conductive Buna N 02 1010 86 FKM 02 1010 53 02 1085 53 EPDM 02 1010 54 02 1060 54 02 1085 54 PTFE 02 1040 55 02 1010 55 02 1010 72 85 02 1085 55 02 1125 55 PTFE Encapsulated FKM 02 1220 60 04 1300 60 500 Non Food Grade Saniflex 02 1031 46 Saniflex 02 1010 56 02 1065 56 02 1031 56 02 1060 56 02 10...

Страница 25: ...WIL 11070 E 16 25 P200 Bolted Plastic NOTES ...

Страница 26: ...WIL 11070 E 16 26 P200 Bolted Plastic NOTES ...

Страница 27: ...WIL 11070 E 16 27 P200 Bolted Plastic NOTES ...

Страница 28: ... USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document WIL 11070 E 16 Where InnovationFlows ...

Отзывы: