WIL-11160-E-10
20
P1500 Bolted Plastic
SECTION 8
P1500 PLASTIC
LW0225 REV. A
ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS
EXPLODED VIEW AND PARTS LIST
Страница 1: ...WIL 11160 E 10 Where InnovationFlows EOM ENGINEERING OPERATION MAINTENANCE MANUAL P1500 Bolted Plastic Pump ...
Страница 2: ... California LLC Wil Flex is a trademark of PSG California LLC Saniflex is a trademark of PSG California LLC All trademarks names logos and service marks collectively trademarks in this document are registered and unregistered trademarks of their respective owners Nothing contained in this document should be construed as granting any license or right to use any trademark without the prior written p...
Страница 3: ...nce 8 P1500 Plastic Reduced Stroke PTFE Fitted 8 P1500 Plastic Full Stroke PTFE Fitted 8 Suction Lift Capability 9 SECTION 6 Suggested Installation Operation Maintenance and Troubleshooting 10 SECTION 7 Disassembly Reassembly 13 Pump Disassembly 13 Air Valve Disassembly 16 Reassembly Hints and Tips 18 Shaft Seal Installation 19 SECTION 8 Exploded View and Parts List 20 SECTION 9 Elastomer Options ...
Страница 4: ...ity is not exceeded CAUTION Do not exceed 8 6 bar 125 psig air supply pressure CAUTION Do not exceed 82 C 180 F air inlet temperature for all models CAUTION The process fluid and cleaning fluids must be compatible chemically with all wetted pump components CAUTION Thoroughly flush pumps before installing them into process lines Clean and or sanitize FDA and USDA approved pumps before using them CA...
Страница 5: ... POLYURETHANE EZ INSTALL CLEAR ZSS SANIFLEX EZ INSTALL HYTREL CREAM ZWS WIL FLEX EZ INSTALL SANTOPRENE THREE BLACK DOTS VALVE BALLS TF PTFE WHITE VALVE SEATS K PVDF VALVE SEATS MANIFOLD O RING TV PTFE ENCAP FKM SPECIALTY CODES 0100 Wil Gard II 110V 0102 Wil Gard II sensor wires Only 0103 Wil Gard II 220V 0206 PFA coated hardware Wil Gard II sensor wires ONLY 0480 Pump Cycle Monitor sensor wires 04...
Страница 6: ...and manifold of the pump These same hydraulic forces lift the discharge valve ball off its seat while the opposite discharge valve ball is forced onto its seat forcing fluid to flow through the pump discharge The movement of diaphragm A toward the center of the pump creates a vacuum within liquid chamber A Atmospheric pressure forces fluid into the inlet manifold of the pump The inlet valve ball i...
Страница 7: ...IA N 150 5 9 FLANGES DIN mm ANSI inch P 160 DIA 6 0 DIA R 191 DIA 7 5 DIA S 18 DIA 0 8 DIA LW0404 REV A P1500 PVDF DIMENSIONS ITEM METRIC mm STANDARD inch A 914 36 0 B 160 6 3 C 694 27 3 D 1278 50 3 E 180 7 1 F 303 11 9 G 1183 46 6 H 694 27 3 J 584 23 0 K 681 26 8 L 335 13 2 M 15 DIA 0 6 DIA N 142 5 6 FLANGES DIN mm ANSI inch P 170 DIA 6 0 DIA R 190 DIA 7 5 DIA S 18 DIA 0 8 DIA A 914 36 0 DIMENSIO...
Страница 8: ... 9 bar 100 psig air supply pressure on Polypropylene pumps Do not exceed 8 6 bar 125 psig air supply pressure on PVDF pumps P1500 PLASTIC FULL STROKE PTFE FITTED Ship Weights Polypropylene 138 kg 305 lb PVDF 161 kg 356 lb Air Inlet 19 mm 3 4 Inlet 51 mm 3 Outlet 51 mm 3 Suction Lift 5 5 m Dry 18 2 8 6 m Wet 28 4 Disp per Stroke1 5 8 L 1 52 gal Max Flow Rate 878 lpm 232 gpm Max Size Solids 12 7 mm ...
Страница 9: ...000 above sea level This chart is meant to be a guide only There are many variables that can affect your pump s operating characteristics The number of intake and discharge elbows viscosity of pumping fluid elevation atmospheric pressure and pipe friction loss all affect the amount of suction lift your pump will attain SUCTION LIFT CAPABILITY ...
Страница 10: ... minute and then multiplying that figure by the displacement per stroke Muffler Using the standard Wilden muffler sound levels are reduced below OSHA specifications You can use other mufflers to reduce sound levels farther but they usually reduce pump performance Elevation Selecting a site that is well within the pump s dynamic lift capability will assure that loss of prime issues will be eliminat...
Страница 11: ...sed to regulate volume Pump discharge rate also can be controlled by throttling the pump discharge by partially closing a valve in the discharge line of the pump This action increases friction loss which reduces flow rate See Performance This is useful when the need exists to control the pump from a remote location When the pump discharge pressure equals or exceeds the air supply pressure the pump...
Страница 12: ... be unable to shift Pump runs but little or no product flows 1 Check for pump cavitation Slow pump speed down to allow thick material to flow into liquid chambers 2 Verify that vacuum required to lift liquid is not greater than the vapor pressure of the material being pumped cavitation 3 Check for sticking ball check valves a If material being pumped is not compatible with pump elastomers swelling...
Страница 13: ...fects of contact with your process fluid NOTE Your specific pump model may vary from the configuration shown however pump disassembly procedure will be the same NOTE The model used for these instructions incorporates PTFE diaphragms and balls Models with rubber diaphragms and balls are the same except where noted NOTE Replace worn parts with genuine Wilden parts for reliable performance Step 1 Ste...
Страница 14: ...intake manifold from liquid chambers and center section to expose intake valve balls and seats Inspect the ball cage area of manifold for excessive wear or damage Repeat Steps 4 6 NOTE Two people or a jib crane is recommended to perform Step 8 Lift one side of the intake manifold then slide out the other side to remove the manifold from the mounting stand Normally inlet and discharge manifolds sho...
Страница 15: ...om the shaft which remains connected to the opposite side diaphragm assembly Figure 10b Repeat disassembly instructions for the opposite liquid chamber Inspect diaphragm assembly and shaft for signs of wear or chemical attack Replace all worn parts with genuine Wilden parts for reliable performance Rubber TPE are not available To remove diaphragm assembly from shaft secure shaft with soft jaws a v...
Страница 16: ...osen the air valve bolts utilizing a 3 8 hex head wrench Remove muffler plate and air valve bolts from air valve assembly exposing muffler gasket for inspection Replace if necessary Lift away air valve assembly and remove air valve gasket for inspection Replace if necessary Step 4 Step 5 Remove air valve end cap to expose air valve spool by simply lifting up on end cap once air valve bolts are rem...
Страница 17: ...pilot spool from bushing and inspect spool and seals for nicks gouges or other signs of wear Replace pilot sleeve assembly or outer bushing O rings if necessary NOTE Seals should not be removed from pilot spool Seals are not sold separately The end of the pilot spool that has a center hole in it should not be fed into the bore first Check center section Glyd rings for signs of wear If necessary re...
Страница 18: ...hite EP bearing grease or equivalent Clean the inside of the center section shaft bore to ensure no damage is done to new seals A small amount of NLGI grade 2 white EP bearing grease can be applied to the muffler and air valve gaskets to locate gaskets during assembly Make sure that the exhaust port on the muffler plate is centered between the two exhaust ports on the center section Stainless bolt...
Страница 19: ... With the seal clamped in the pliers insert the seal into the busing bore and position the bottom of the seal into the correct groove When the bottom of the seal is seated in the groove release the clamp pressure on the pliers This will allow the seal to partially snap back to its original shape 6 After removing the pliers you will notice a slight bump in the seal shape Before the seal can be resi...
Страница 20: ...WIL 11160 E 10 20 P1500 Bolted Plastic SECTION 8 P1500 PLASTIC LW0225 REV A ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS EXPLODED VIEW AND PARTS LIST ...
Страница 21: ... 15 5185 20 15 5185 21 24 O Ring Tee Section 347 Ø4 225 x Ø 210 4 15 1300 60 25 Elbow Combo 4 15 5240 20 15 5240 21 26 O Ring Elbow 363 Ø6 475 X Ø 210 4 15 1370 60 27 Cage Ball 4 15 5350 20 15 5350 21 28 Screw HHC 3 4 10 x 8 3 8 24 15 6192 03 29 Washer Plain 3 4 Ø 812 x Ø1 750 x 095 48 15 6735 03 30 Nut Hex 3 4 10 24 15 6425 03 31 Chamber Liquid 2 15 5000 20 15 5000 21 32 Stand Pump 1 15 7650 03 V...
Страница 22: ... 2 EZ INSTALL DIAPHRAGMS 2 FULL STROKE IPD DIAPHRAGMS 2 VALVE BALLS 4 Polyurethane 15 1022 50 Neoprene 15 1060 51 Geolast 15 1022 15 EPDM 15 1060 54 PTFE 15 1010 55 15 1040 55 15 1085 55 Non Food Grade SaniflexTM 15 1031 46 SaniflexTM 15 1065 56 15 1022 56 FDA Wil FlexTM 15 1065 57 15 1022 57 15 1085 57 Wil FlexTM 15 1022 58 15 1031 58 15 1085 58 LW0226 REV A ELASTOMER OPTIONS ...
Страница 23: ...WIL 11160 E 10 23 P1500 Bolted Plastic NOTES NOTES ...
Страница 24: ... USA P 1 909 422 1730 psgdover com Copyright 2021 PSG a Dover Company PSG reserves the right to modify the information and illustrations contained in this document without prior notice This is a non contractual document WIL 11160 E 10 Where InnovationFlows ...