NT 1010-I00 03 18 Submerged AM unit on plate  e

The operator should remain nearby the equipment through-
out the use to ensure the proper functioning of the system.

6.1 Pumping hot liquids

When pumping hot liquids, make your you retighten
screws and bolts after starting for the first time in order
to compensate for contraction.

6.2 Pump full of liquid when stopped

If the pump circuit is to be located between valves and/or
a non-return valve, you need to take account of the
variations in temperature that can lead to contraction of
the liquid in the circuit. In this case, you need to provide
some means of compensating for the contraction. A dis-
charge valve may be sufficient. The opening pressure
for this valve should be compatible with the permitted
pressure for the other components in the circuit.

It is also advisable to fit a discharge device to allow the
circuit to be completely emptied for any maintenance work.

In the case of liquids containing particles settling on
shut-down, it is necessary to make sure the consistency
of the deposit will not impede restarting the pump.

6.3 Starting-up the pump

Before starting the pump, make sure that the following
conditions are met :

• The circuit should be in one of its pumping configu-

rations, with the appropriate valves open, especially
on the intake side.

• For products requiring heating, they must be brought

to their pumping temperature before starting the
pump.

6.4 Running without liquid in the pump

MOUVEX Submerged AM pumps can run without liquid
in the pump for 5 minutes without causing damage, in
particular during pump priming.

6.5 Using of the pump with a valve closed on

the discharge line

The using of the pump with a valve closed on the dis-
charge line implies the liquid is not renewed which gene-
rates a heating up. In consequence, that operating way
must not exceed 3 minutes.

6.6 Shutting down the pump

When shutting down the pump, we recommend waiting
for it to stop completely before closing the valves, espe-
cially the inlet valve.

CAUTION

THE SURFACES OF THE PUMP CAN
BE AT A TEMPERATURE LIABLE TO
CAUSE INJURY OR SEVERE DAMAGE.

Excessive temperature-

can cause injury 

or severe damage.

WARNING

FAILURE TO INSTALL ADEQUATELY
SIZED PRESSURE RELIEF VALVE(S)
CAN CAUSE PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH.

Hazardous pressure 

can cause 

personal injury 

or property damage.

WARNING

IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, THE SYSTEM MUST BE FLUS-
HED PRIOR TO PERFORMING ANY
SERVICE OPERATION.

Toxic or hazardous

fluids can cause 

serious injury.

WARNING

FAILURE TO RELIEVE SYSTEM
PRESSURE PRIOR TO PERFORMING
PUMP SERVICE OR MAINTENANCE
CAN CAUSE PERSONAL INJURY OR
PROPERTY DAMAGE.

Hazardous pressure 

can cause 

personal injury 

or property damage.

WARNING

OPERATION WITHOUT THE SHAFT
PROTECTOR CAN CAUSE SERIOUS
PERSONAL INJURY, MAJOR PROPER-
TY DAMAGE OR DEATH.

Do not operate

without guard 

in place.

6. USE

Содержание PSG MOUVEX SUBMERGED AM UNIT ON PLATE

Страница 1: ... Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com WARRANTY Submerged AM units on plate are covered 24 months by warranty within the limits mentioned in our General Sales Conditions In case of a use other than that mentioned in the Instructions manual and without preliminary agreement of MOUVEX warranty will be canceled ...

Страница 2: ...th a valve closed on the discharge line 7 6 6 Shutting down the pump 7 6 7 Protection from frost 8 6 8 Restarting 8 6 9 Operation limits 8 6 10 3 way valve operation 8 6 11 Clutch 8 6 12 Tank emptying with pump 8 6 13 Change of product 8 6 14 Pump emptying 8 6 15 Pump filling solvent 9 6 16 Pump rinsing 9 6 17 Pump emptying solvent evacuation 9 6 18 Check of pump rinsing and unsticking 9 6 19 Rota...

Страница 3: ...Q 1 Right valve positioning plate P 1 Left valve positioning plate M 1 Operating lever K 1 Flush pipe J 1 Funnel flushing valve H 1 Pump draining device F 2 Valve grease nipple E 1 Bypass cap G 2 Left valve rod D 2 Right valve rod C 2 3 ways valve T with C flanges gaskets B 1 Spherical frame A 1 AM pump flanged Weight 225 kg ...

Страница 4: ...pe diameter In order to achieve the best usage conditions it is impor tant to take the following recommendations into account when it comes to pipe dimensions The pipe diameter should be chosen as a function of pipe length and the flow rate and viscosity of the pum ped liquid so that any head loss remains within the per missible limits for the motor pump unit Therefore it is difficult to give gene...

Страница 5: ... motors must be protected by appropriate circuit breakers and fuses Connect the regulatory ground connections Check the direction of rotation This check should be done with no liquid being pumped and both the inlet and discharge circuits vented to avoid generating unexpected pressure on the inlet side for example This will avoid damaging either the pump or the system WARNING OPERATION WITHOUT THE ...

Страница 6: ...reversible It is therefore vital to carefully check the inlet and outlet sides of the pump before connecting the pump unit to the piping The use of diesel engines drive is now well known Nevertheless we strongly recommend that you carefully read the technical manuals concerning them CAUTION THE SURFACES OF THE PUMP CAN BE AT A TEMPERATURE LIABLE TO CAUSE INJURY OR SEVERE DAMAGE Excessive temperatu...

Страница 7: ...ing heating they must be brought to their pumping temperature before starting the pump 6 4 Running without liquid in the pump MOUVEX Submerged AM pumps can run without liquid in the pump for 5 minutes without causing damage in particular during pump priming 6 5 Using of the pump with a valve closed on the discharge line The using of the pump with a valve closed on the dis charge line implies the l...

Страница 8: ...ge the the clutch very slowly If clutch is engaged roughly damage to equipment may result breaking of shaft If resistance is encountered due to sticking of the pump stop the engine and carry out the procedure described in CHECK OF PUMP RINSING AND UNSTICKING 6 12 Tank emptying with pump Make sure all the valves in the delivery system are open before coupling the engine 6 13 Change of product If th...

Страница 9: ...erator always check that pump was rinsed by rotating the pump by hand before allowing new fluid to enter the pump If the pump sticks perform steps 8 and 9 above mentio ned and then before performing steps 10 11 12 13 15 and 16 be sure that the solvent has unstuck the pump by rotating the pump by hand This procedure prevents deterioration shaft breaking packing removal Do not omit to close the pump...

Страница 10: ...SLIPPE RY AND MAY CAUSE SERIOUS INJURY ANY SPILLS MUST BE CLEANED UP Slippery lubricant Spills should be cleaned up WARNING FAILURE TO RELEASEALL SYSTEMAIR AND WHEN EQUIPPED HYDRAULIC PRESSURE CAN CAUSE PROPERTY DAMAGE PERSONALINJURYORDEATH Hazardous pressure can cause personal injury or property damage WARNING DISCONNECT THE ELECTRICITY SUPPLY BEFORE ANY MAINTENAN CE OPERATION Dangerous voltage C...

Страница 11: ... assembly including bea ring cage 701 bearing 703 protection ring 733 by tap ping on shaft drive end Then remove seal 605 counterplate 604 and afterwards one piece rotary assembly 697 8 4 Reassembly Check seals of one piece rotary assembly 697 seals 605 and 707 for good condition Check new parts for condition of mating faces of counter place 604 and one piece rotary assembly 697 Install all parts ...

Страница 12: ... relative humidity does not exceed 60 exposure to vibration is limited pump is stored in an area sheltered from bad wea ther and sun 10 2 Long duration 1 month The recommendations from the manufacturer should be followed if the pump is stored with its gear motor Pump ports should be filled with a non corrosive liquid that it compatible with the pump components in order to prevent corrosion Unpaint...

Страница 13: ...kehrungen bezogen auf mechanische und elektrische Risiken die für rotierende Maschinen gelten NF EN 809 2009 NF EN 1672 2 2009 NF EN ISO 13857 2008 NF EN 12162 2009 ATEX Richtlinie 2014 34 EU 26 Feb 2014 wie umgesetzt im nationalen Recht in Bezug auf Ausrüstungen für den Einsatz in explosionsgefährdeter Atmosphäre Die Konformität hat Geltung durch Anwendung folgender Normen NF EN 1127 1 1997 NF EN...

Отзывы: