Dover PSG MOUVEX SUBMERGED AM UNIT ON PLATE Скачать руководство пользователя страница 1

Submerged AM 

Unit on plate

INSTRUCTIONS 1010-I00 e

Section          1010

Effective        March 2018

Replaces       March 2017

Translation of the 

original instructions 

INSTALLATION

OPERATION

MAINTENANCE

Your distributor :

Z.I. La Plaine des Isles - F 89000 AUXERRE - FRANCE

Tel. : +33 (0)3.86.49.86.30 -  Fax : +33 (0)3.86.49.87.17

[email protected]  -  www.mouvex.com

WARRANTY :

Submerged AM units on plate are covered 24 months by warranty within the limits mentioned in our General Sales Conditions. 
In case of a use other than that mentioned in the Instructions manual, and without preliminary agreement of MOUVEX,
warranty will be canceled.

Содержание PSG MOUVEX SUBMERGED AM UNIT ON PLATE

Страница 1: ... Z I La Plaine des Isles F 89000 AUXERRE FRANCE Tel 33 0 3 86 49 86 30 Fax 33 0 3 86 49 87 17 contact mouvex com www mouvex com WARRANTY Submerged AM units on plate are covered 24 months by warranty within the limits mentioned in our General Sales Conditions In case of a use other than that mentioned in the Instructions manual and without preliminary agreement of MOUVEX warranty will be canceled ...

Страница 2: ...th a valve closed on the discharge line 7 6 6 Shutting down the pump 7 6 7 Protection from frost 8 6 8 Restarting 8 6 9 Operation limits 8 6 10 3 way valve operation 8 6 11 Clutch 8 6 12 Tank emptying with pump 8 6 13 Change of product 8 6 14 Pump emptying 8 6 15 Pump filling solvent 9 6 16 Pump rinsing 9 6 17 Pump emptying solvent evacuation 9 6 18 Check of pump rinsing and unsticking 9 6 19 Rota...

Страница 3: ...Q 1 Right valve positioning plate P 1 Left valve positioning plate M 1 Operating lever K 1 Flush pipe J 1 Funnel flushing valve H 1 Pump draining device F 2 Valve grease nipple E 1 Bypass cap G 2 Left valve rod D 2 Right valve rod C 2 3 ways valve T with C flanges gaskets B 1 Spherical frame A 1 AM pump flanged Weight 225 kg ...

Страница 4: ...pe diameter In order to achieve the best usage conditions it is impor tant to take the following recommendations into account when it comes to pipe dimensions The pipe diameter should be chosen as a function of pipe length and the flow rate and viscosity of the pum ped liquid so that any head loss remains within the per missible limits for the motor pump unit Therefore it is difficult to give gene...

Страница 5: ... motors must be protected by appropriate circuit breakers and fuses Connect the regulatory ground connections Check the direction of rotation This check should be done with no liquid being pumped and both the inlet and discharge circuits vented to avoid generating unexpected pressure on the inlet side for example This will avoid damaging either the pump or the system WARNING OPERATION WITHOUT THE ...

Страница 6: ...reversible It is therefore vital to carefully check the inlet and outlet sides of the pump before connecting the pump unit to the piping The use of diesel engines drive is now well known Nevertheless we strongly recommend that you carefully read the technical manuals concerning them CAUTION THE SURFACES OF THE PUMP CAN BE AT A TEMPERATURE LIABLE TO CAUSE INJURY OR SEVERE DAMAGE Excessive temperatu...

Страница 7: ...ing heating they must be brought to their pumping temperature before starting the pump 6 4 Running without liquid in the pump MOUVEX Submerged AM pumps can run without liquid in the pump for 5 minutes without causing damage in particular during pump priming 6 5 Using of the pump with a valve closed on the discharge line The using of the pump with a valve closed on the dis charge line implies the l...

Страница 8: ...ge the the clutch very slowly If clutch is engaged roughly damage to equipment may result breaking of shaft If resistance is encountered due to sticking of the pump stop the engine and carry out the procedure described in CHECK OF PUMP RINSING AND UNSTICKING 6 12 Tank emptying with pump Make sure all the valves in the delivery system are open before coupling the engine 6 13 Change of product If th...

Страница 9: ...erator always check that pump was rinsed by rotating the pump by hand before allowing new fluid to enter the pump If the pump sticks perform steps 8 and 9 above mentio ned and then before performing steps 10 11 12 13 15 and 16 be sure that the solvent has unstuck the pump by rotating the pump by hand This procedure prevents deterioration shaft breaking packing removal Do not omit to close the pump...

Страница 10: ...SLIPPE RY AND MAY CAUSE SERIOUS INJURY ANY SPILLS MUST BE CLEANED UP Slippery lubricant Spills should be cleaned up WARNING FAILURE TO RELEASEALL SYSTEMAIR AND WHEN EQUIPPED HYDRAULIC PRESSURE CAN CAUSE PROPERTY DAMAGE PERSONALINJURYORDEATH Hazardous pressure can cause personal injury or property damage WARNING DISCONNECT THE ELECTRICITY SUPPLY BEFORE ANY MAINTENAN CE OPERATION Dangerous voltage C...

Страница 11: ... assembly including bea ring cage 701 bearing 703 protection ring 733 by tap ping on shaft drive end Then remove seal 605 counterplate 604 and afterwards one piece rotary assembly 697 8 4 Reassembly Check seals of one piece rotary assembly 697 seals 605 and 707 for good condition Check new parts for condition of mating faces of counter place 604 and one piece rotary assembly 697 Install all parts ...

Страница 12: ... relative humidity does not exceed 60 exposure to vibration is limited pump is stored in an area sheltered from bad wea ther and sun 10 2 Long duration 1 month The recommendations from the manufacturer should be followed if the pump is stored with its gear motor Pump ports should be filled with a non corrosive liquid that it compatible with the pump components in order to prevent corrosion Unpaint...

Страница 13: ...kehrungen bezogen auf mechanische und elektrische Risiken die für rotierende Maschinen gelten NF EN 809 2009 NF EN 1672 2 2009 NF EN ISO 13857 2008 NF EN 12162 2009 ATEX Richtlinie 2014 34 EU 26 Feb 2014 wie umgesetzt im nationalen Recht in Bezug auf Ausrüstungen für den Einsatz in explosionsgefährdeter Atmosphäre Die Konformität hat Geltung durch Anwendung folgender Normen NF EN 1127 1 1997 NF EN...

Отзывы: