![Dover PSG A40 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/dover/psg-a40/psg-a40_instructions-manual_2524992010.webp)
10/19
NT 1101-F00 08.10 A40 - AS40 e
TOP PORT
Repeat the steps described above from 2 to 10.
11. Operate the pump intermittently until the hose is com-
pletely out.
12. Disconnect the pump.
4.1.2 DISASSEMBLING THE COVER
1. Loosen screws
33
and remove the washers
34
.
2. Loosen nuts
36
and remove the washers
35
.
3. Remove the cover
2
, be careful with the weight of the
cover.
4. Wash the inside of the pump body
1
and the cover
2
with water or a cleaning product that is compatible with
the pump materials. Also wash the wheel (front + back).
4.1.3 ASSEMBLING THE COVER
1. After a visual inspection of the inside of the body and
the wheel, lubricate all the internal parts of the casing
with pump lubricant.
2. Assemble the cover
2
.
3. Place the washers
35
.
4. Tighten the nuts
36
.
5. Place the washers
34
and tighten the screws
33
.
4.1.4 ASSEMBLING THE HOSE
1. Clean the hose
16
to eliminate any particles that may
have adhered to it (gravel, etc.).
2. Generously coat the hose with lubricant.
3. Insert the loose end of the hose
16
in the inlet port of
the pump body
1
.
4. Operate the pump intermittently until the hose
16
is
completely inserted in the body
1
so that the same
length protrudes from both ports of the body.
WARNING
Do not operate
without guard
in place.
NEVER INSERT THE HOSE OR RUN THE
PUMP WITHOUT ITS COVER AND ITS WIN-
DOW IN PLACE.
16
1
WARNING
The weight ot the parts can
be dangerous and may
provoke bodily injuries or
material damages.
BE CAREFUL WITH THE WEIGHT OF
THE PARTS WHEN THEY ARE BEING
REMOVED.
NOTES
If the pump is not re-assembled immediately, dry
unpainted surfaces and coat them with the pump
lubricant in order to protect them against corrosion.
Dispose of the drained products in accordance with
the rules and regulations in force.
WARNING
The weight ot the parts can
be dangerous and may pro-
voke bodily injuries or mate-
rial damages.
BE CAREFUL WITH THE WEIGHT OF THE
COVER WHEN IT IS BEING REMOVED.
THE HOSE CAN BE EXPELLED VIOLENTLY.
BE SURE NO ONE IS IN FRONT OF PUMP
PORTS.
WARNING
Hazardous machinery
can cause severe
personal injury
or property damage.
DISCONNECT THE ELECTRICITY SUPPLY
BEFORE ANY MAINTENANCE OPERATION.
WARNING
Dangerous voltage.
Can cause
injury and death
.
4. MAINTENANCE OPERATIONS (continued)