9.Turn the print module over and re -
position the air pipes and ribbon cable.
10.Re-fit the cover plate, ensuring that
the ribbon cable and air pipes are not
trapped.
11.Re-connect the print module to the
adaptor plate and secure the screws.
12.Re-connect the printhead to the
print module.
13.Re - fit the finger guard and the
printer covers.
Note:
Ensure that the air pipes run in the channel in the adaptor plate and that
they are not trapped. When replacing the screws use Loctite 222 retaining
fluid.
Note:
After re- handing the print module it will also be necessary to re-hand the
printer cassette. See the following pages for details.