SECTION 2 - SETUP AND TIMING ISSUES
2-20
SmartDate 5
08/08
Resolution
This sets the period between speed samples in the profile.
The speed profile once initiated records 1500 speed samples.
A low resolution (100 ms) will record over a longer period. (2.5 mins)
A high resolution (1 ms) will record over a shorter period but will provide more
detailed information. (1.5 secs)
Trigger
The Trigger option allows you to set what action initiates the start of the Speed
Profile.
Manual Trigger
This allows you to manually initiate the start of the speed profile. With the
SmartDate 5 set to producing mode, access the speed profile menu. Press
“Select” to initiate the start of the speed profile.
Print Go Trigger
will initiate the start of the Speed profile after the SmartDate 5 is
set to producing mode and then receives the first Print Go signal.
Note:
Using the manual option allows you to start the profile from the SmartDate
5, SmartTouch controller or the PC application.
Содержание markem-imaje SmartDate 5
Страница 1: ... ...
Страница 2: ......
Страница 9: ...SmartDate 5 Maintenance Manual SECTION 1 GENERAL INFORMATION ...
Страница 10: ......
Страница 13: ...SmartDate 5 Maintenance Manual SECTION 2 SETUP AND TIMING ISSUES ...
Страница 14: ......
Страница 37: ...SmartDate 5 Maintenance Manual SECTION 3 MAINTENANCE ...
Страница 38: ......
Страница 77: ...SmartDate 5 Maintenance Manual SECTION 4 TECHNICAL INFORMATION ...
Страница 78: ......
Страница 145: ...SmartDate 5 Maintenance Manual SECTION 5 TROUBLESHOOTING ...
Страница 146: ......
Страница 189: ...SmartDate 5 Maintenance Manual SECTION 6 RECOMMENDED SPARES ...
Страница 190: ......
Страница 197: ......
Страница 198: ...User Documentation Department ...