installation / maintenance

1.  Mount the unit in a level position on the side of a reservoir. The U-clamp may be repositioned or removed as necessary.

2.  Install a minimum 3/8” ID water hose between the inlet threads and the water spigot. Minimum water pressure required 

  to properly operate the proportioner is 20 PSI dynamic.

3.  Attach the end of the discharge tube with the clamp and flooding ring to the discharge barb on the eductor.

4.  Insert the foot valve end of the suction tube into the concentrate container. (The level of the concentrate must be below 

  the level of the eductor, or the proportioner will continue to siphon concentrate after it is turned “off”.)

 

REMEMBER TO CHECK FOOT STRAINERS PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY

5.  Select a push-in metering tip or ULD. Install push-in metering tip it into the suction stub on the eductor body.

  Install ULD into inlet of eductor body.

6.  Slide the open end of the suction tube over the suction stub.

7.  Adjust the bead chain length to position the float at the desired level of solution. To prevent foaming, be certain that the 

  solution level will always be above the point of discharge. Be sure float mechanism is not hampered by water turbulence 

  caused by discharging solution. It may be necessary to baffle the float from the discharge in order for the unit to work 

 properly.

Page 3

operation

1.  Connect opposite end of water inlet hose to water supply. Turn on water supply.

2.  Prime the system by activating the water valve by pulling down on the yoke.

 

NOTE: In order to fully prime a ULD system, continue activating the water valve for 30 seconds after chemical has reached the ULD inlet.  

 

There may be some water discharge from the eductor vents until the air is purged.

tip/uld chart

Metering Tip Selection:

The final concentration of the dispensed solution is related to both the size of the 

metering tip opening and the viscosity of the liquid being siphoned. For water-thin 

products, the chart at right can be used as a guideline. If product is noticeably 

thicker than water, consult the Measurement of Concentration Procedure below to 

achieve your desired water-to-product ratio. Because dilution can vary with water 

temperature and pressure, actual dilution achieved can only be ascertained by using 

the Measurement of Concentration Procedure. The clear, undrilled tip is provided 

to permit drilling to size not listed should you need a dilution ratio that falls between 

standard tip sizes.

NOTE: A 5 GPM eductor is blue. Refer to parts diagram if unfamiliar with names of 

system components.

Measurement of Concentration:

You can determine the dispensed water-to-product ratio for any metering tip size 

and product viscosity. All that is required is to operate the primed dispenser for a 

minute or so and note two things: the amount of dispensed solution, and the amount 

of concentrate used in preparation of the solution dispensed. The water-to-product 

ratio is then calculated as follows:

Dilution Ratio (X:1) where X = Amount of Mixed Solution — Amount Concentrate Drawn

 

  

 

 

 

Amount of Concentrate Drawn 

Dilution Ratio, then, equals X parts water to one part concentrate (X:1). If  the test 
does not yield the desired ratio, choose a different tip and repeat the test. Alternative 
methods to this test are 1) pH (using litmus paper), and 2) titration. Contact your 
concentrate supplier for further information on these alternative methods and the 

materials required to perform them.

APPROXIMATE DILUTIONS

AT 40 PSI FOR WATER-THIN PRODUCTS (1.0 CP)

Tip/ULD

Color

Tip or ULD

Ratio (per Eductor Flow)

5 GPM

Grey

Tip

7:1

Black

Tip

8:1

Beige

Tip

12:1

Red

Tip

18:1

White

Tip

30:1

Blue

Tip

33:1

Tan

Tip

45:1

Green

Tip

55:1

Orange

Tip

85:1

Brown

Tip

110:1

Yellow

Tip

155:1

Aqua

Tip

175:1

Purple

Tip

260:1

Pink

Tip

550:1

Red One

ULD

300:1

Dark Blue One

ULD

400:1

White Two

ULD

500:1

Light Blue One

ULD

550:1

Orange One

ULD

600:1

Yellow One

ULD

800:1

Purple One

ULD

900:1

Pink One

ULD

1000:1

Dark Green One

ULD

1100:1

Yellow Two

ULD

1200:1

Purple Two

ULD

1500:1

Light Blue Five

ULD

1800:1

Yellow Four

ULD

1900:1

Purple Four

ULD

2400:1

Purple Five

ULD

2500:1

Содержание Hydro HydroMinder

Страница 1: ...user manual HydroMinder Car Wash ...

Страница 2: ...pment carefully and observe all warnings and cautions NOTE WEAR protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all chemicals filling or emptying equipment or changing metering tips ALWAYS observe safety and handling instructions of the chemical manufacturer direct discharge away from you or other persons or into approved containers d...

Страница 3: ...rt at right can be used as a guideline If product is noticeably thicker than water consult the Measurement of Concentration Procedure below to achieve your desired water to product ratio Because dilution can vary with water temperature and pressure actual dilution achieved can only be ascertained by using the Measurement of Concentration Procedure The clear undrilled tip is provided to permit dril...

Страница 4: ...ULD identification Active disc chart on the side of ULD 1 ACTIVE 2 ACTIVE 3 ACTIVE 4 ACTIVE 5 ACTIVE Page 4 ...

Страница 5: ...YD10099886 mounting bracket kit l screw m Z bracket n U clamp o lockwasher not shown p thumbscrew 8 HYD520000 water valve body 9 HYD10092506 cast manifold 10 HYD622900 coupling 11 HYD10091989 adapter apad 12 HYD10099885 Kit 5 gpm e gap 13 HYD3401 R hosebarb assembly 14 HYD690014 metering tip kit 15 HYD10099869 Kit ULD 300 550 HYD10099870 Kit ULD 600 1000 HYD10099871 Kit ULD 1100 1700 HYD10099872 K...

Страница 6: ...4 Failure of unit to turn off a Push button stuck a Remove button and clean cabinet button to remove excess dirt lodged in slide recess b Magnet doesn t fully return b Make sure magnet moves freely Replace spring if short of weak c Water valve parts dirty or defective c Clean or replace with valve parts kit 5 Excess foaming in discharge a Air leak in pick up tube a Put clamp on tube or replace tub...

Отзывы: