TL 1128 (TOP HOLES)
Issued August 2016
Revision No: 006
Printed in U.S.A.
Copyright 2016, Bayne Premium Lift Systems
Installation Instructions
8
1. Cut or disconnect truck’s main hydraulic pressure line and install the diverter valve in series using the “IN” and “OUT”
ports.
2. Connect the “T” port on the diverter valve to the truck’s hydraulic tank line with an appropriate size line to handle the
lifter system flow. (approximately 5 GPM max.)
3. Connect the “P1” port on the diverter valve to the “IN” port on the hand valve.
If installing dual lifters, connect the
“P2” port on the diverter valve to the “IN” port on the other hand valve.
4. Connect the “T1” port on the diverter valve to the “OUT” port on the hand valve.
If installing dual lifters, connect
the “T2” port on the diverter valve to the “OUT” port on the other hand valve.
5. Connect the “A” port on the hand valve(s) to the “UP” port of the rotary actuator(s).
6. Connect the “B” port of the hand valve(s) to the “DOWN” port of the rotary actuator(s).
7. Disassemble each hose clamp assembly and position weld plates where needed and weld in place.
8. After the weld has cooled, paint the weld plates to match the truck color.
9. After the paint has dried, reassemble the hose clamp assemblies around the hoses.
E. Adjusting relief valve settings :
The diverter valve ( 1 ) ( Figure A-4 ) supplies the cart lifter hydraulic system with approximately 2 GPM of oil flow. This
diverter valve is equipped with a lifter circuit relief valve ( 3 ) set at 2300 psi, to prevent the diverter valve from shutting
down if a blockage occurs in the lifter circuit. There is also a relief valve ( 5 ) set at 1800 psi in the hand valve ( 2 ) to
protect the lifter from excessive pressure. These relief valves are preset from the factory to operate properly on most
trucks with a system pressure between 2300 and 2500 psi without any adjustment. However, if any adjustment is
necessary, follow these instructions.
WARNING
Bayne equipment is rated for a maximum pressure of 3000 psi. Operation at pressures above 3000 psi may damage
equipment and cause personal injury. In order to avoid injury and maintain manufacturer’s warranty never operate above
3000 psi.
Figure A-4
Содержание Environmental Solutions BAYNE TL 1128
Страница 4: ...INTENTIONALLY LEFT BLANK TL 1128 TOP HOLES ...
Страница 54: ...INTENTIONALLY LEFT BLANK 50 TL 1128 TOP HOLES ...