5. Operating troubles, causes and remedial action
No.
Operating troubles
Causes and remedial
action
Pump
does
not
start
Pump
does
not
prime
Delivery
is not
ob-
tained
or
reduced
Pressure
head is
not
obtained
Irreg-
ular
pump
delivery
Pump
oper-
ates
noisily
Pump
is
leaky
Motor
gets
too
warm
Display
show
Error
code
5.1 5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
The 4-piston diaphragm pump
operates trouble-free at any time
provided they are applied according to
the operating conditions mentioned in
this manual.
If you have any questions, please
contact Quattroflow.
1
X
X
The screws of the pump-chamber
maybe not tightened enough. Fix it!
2
X
Check the direction of flow showed by
the arrow on the pump, in case of
wrong way, turn the pump head
3
X
X
X
Check suction pipeline and TC- seals
for tightness
4
X
X
X
X
Check suction head-increase suction
line cross section.
5
X
X
X
Check viscosity of liquid pumped.
6
X
Check pump speed. Control speed of
drive motor. Check voltage and
frequency
7
X
X
X
Avoid air inclusions in the liquid to be
pumped
8
X
X
Check pressure head-open valve in
discharge line completely, remove
obstruction in discharge line
9
X
Pressure line completely or partly
clogged Diaphragm maybe broken
Change diaphragm!
10
X
The diameter of the pipes in suction
or pressure line are to small
11
X
Check the coupling halves. They must
be fixed with at least 2-3mm space.
12
X
Check longitudinal play of coupling rod
pins. The spider might be worn.
13
X
X
X
Check whether foreign bodies in pump.
Disassemble pump, remove foreign
bodies, replace defective parts
14 X
X
Pump stopped by the Thermistor
switch. Please allow the motor to cool
down – please reduce the power
consumption.
15 X
X
Bearings are worn or defective.
Disassemble pump, replace the shaft –
bearing unit
16
X
The valves are dry (i.e. not in use for a
long time), deformed or worn. Change
valve or wet the pump.
17
X
The diaphragm is burst ( the discharge
pressure was too high) - replace it with
PSKITQ20k
18
X
X
X
X
O – rings between valve plate and
pump housing are defective - replace
it with PSKITQ4k
19
X
Align coupling accurately
20
X
X
The clamping ring screw got loose – fix
it! See 4.2 Mount the pump chamber
(picture 2 )