4.3 Changing seals and diaphragms: 

 

The changing of the diaphragm and the valves can be done by the user. 
Please follow the schematic drawings “4.1 Dismount he pump chamber” 

Spare part kit: PSKITQF4400

 

 
 

 

 

 

 

 

 

 

 

 

Please follow the schematic drawings of “4.2 Mount the pump chamber” 

 

 
 
 

Содержание Almatec Quattroflow-QF4400 Series

Страница 1: ...s must be read by the user and must always be available at the place of installation Performance Data The exact performance data applying to the pump are to be taken from the order data sheet These Operating and Maintenance instructions contain information from the pump manufacturer They may need to be supplemented by instructions of the operator company for its personnel ALMATEC Maschinenbau GmbH...

Страница 2: ... Pump 3 1 Application and range of utilization of the Quattroflow QF4400 pump 3 2 Typical application of the Quattroflow QF4400 pump 3 3 Description of the function of the Quattroflow QF4400 pump 3 4 Start up 4 Maintenance and servicing of the Quattroflow QF4400 pump 4 1 Dismount the pump chamber 4 2 Mount the pump chamber 4 3 Changing seals and diaphragms 4 4 Changing of the shaft bearing unit 5 ...

Страница 3: ...rve safety purposes The use of other parts may cancel the liability for the consequences resulting there from Manufacturer ALMATEC Maschinenbau GmbH Carl Friedrich Gauss Str 5 D 47475 Kamp Lintfort Germany Phone 49 2842 961 0 Fax 49 2842 961 40 e mail quattroflow almatec de Internet www quattroflow com 1 2 Labelling of the pump The type label of each Quattroflow pump can be seen on the bottom of t...

Страница 4: ...mp itself or to parts of the system are marked with the word or indication ATTENTION Pmax 8bar Direction of flow Removing or damaging warning labels and signs is prohibited 2 2 Precautions for maintenance inspection mounting and operation The customer shall see to it that all maintenance inspection and mounting operations are performed by authorized and qualified personnel Pump maintenance should ...

Страница 5: ...nnel Maintenance and service of the pump must be performed while the pump is stopped Pumps or aggregates handling hazardous fluids must be decontaminated 2 7 Arbitrary reconstruction and spare part construction Reconstruction of or changes to the machine are only admissible after consultation with the manufacturer Original spare parts and accessories authorized by the manufacturer serve safety pur...

Страница 6: ...o cool down after heat treatment i e CIP SIP Flush the pump prior to use with appropriate fluid i e buffer Foundation design The foundation must be designed so that it can take the weight of the pump aggregate on the entire surface Please make sure that the pump is operated with the proper mains voltage and frequency to avoid damages and electrical danger Make sure that the slots for the cooling a...

Страница 7: ... rating for the full range of temperatures that are applied Pmax 8 bar Do not exceed Warning Label p max 8 bar Do not remove If the maximum pressure is exceeded it can happen that the diaphragm of the pump will burst In this case the fluid will come out of the pump and can cause a danger for the personnel and or environment i e caustic cleaner The Quattroflow QF4400 pump can pump air which means t...

Страница 8: ... frame depth filters Chromatography Packing of chromatography columns Feed pump to mix gradients Feed pump for centrifuges or separators Feed pump for homogenizers Feed pump for filling machines 3 3 Discription of the working princaple Quattroflow QF4400 The Quattroflow QF4400 pump is a 4 piston diaphragm pump The 4 segments of the pump diaphragm oscillate back and forth This alternate movement is...

Страница 9: ... For flushing out of any cleaning agent do not recirculate Check with appropriate analytical methods the success of the flushing procedure Recommendation Test run prior first use Before using your pump in your process for example as recirculation pump in a TFF system perform a test run to get used to the specific properties of the pump Please note ALMATEC Maschinenbau GmbH is also building custom ...

Страница 10: ...eeds to be replaced It is recommended to check the ball bearings replace the ball bearings if the ball bearings are hard to turn or are noisy during operation Attention Safety precautions After purging the pump with air there might be a small residual amount of fluid inside the pump chamber Flush the pump chamber thoroughly and check the rinse fluid P h ousing lease follow the general guidelines a...

Страница 11: ...of April 2009 Page 11 of 16 4 1 Dismount the pump chamber The dismounting of the pump chamber can be done by the user 4 2 Mount the pump chamber The mounting of the pump chamber can be done by the user as well ...

Страница 12: ... seals and diaphragms The changing of the diaphragm and the valves can be done by the user Please follow the schematic drawings 4 1 Dismount he pump chamber Spare part kit PSKITQF4400 Please follow the schematic drawings of 4 2 Mount the pump chamber ...

Страница 13: ...unit The changing of the shaft bearing unit can be done by the user Please follow the schematic drawings 4 1 Dismount the pump chamber 4 Mounting in reverse order with the new shaft bearing unit 5 Please follow the schematic drawings of chapter 4 2 Mount the pump chamber ...

Страница 14: ...requency 7 X X X Avoid air inclusions in the liquid to be pumped 8 X X Check pressure head open valve in discharge line completely remove obstruction in discharge line 9 X Pressure line completely or partly clogged Diaphragm maybe broken Change diaphragm 10 X The diameter of the pipes in suction or pressure line are to small 11 X Check the coupling halves They must be fixed with at least 2 3mm spa...

Страница 15: ... motor is directly coupled to pump Pump rpm motor rpm If reducer gear drives are used Pump rpm motor rpm x reduction ratio Performance Chart Quattroflow 4400 S Test Media Water at Ambient Temperature 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 5500 5750 6000 6250 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 rpm L hr 1 Testlau...

Страница 16: ...316L optional 1 4539 e polished Ra 0 4µm Ferrite 1 Pump housing Stainless steel 1 4435 optional 1 4539 e polished Ra 0 4µm Ferrite 1 Connector inlet standard other dimensions are available TC clamp 1 5 Stainless steel 1 4435 optional 1 4539 e polished Ra 0 4µm Flange diameter inlet 50 5 mm Internal diameter inlet 34 5 mm Connector outlet standard other dimensions are available TC clamp 1 5 Stainle...