TPS-200
Lit. No. 11814, Rev. 00
8
October 1, 2017
WARNING
Gasoline is highly
fl
ammable and gasoline
vapor is explosive. Never smoke while
working on the equipment. Keep all open
fl
ames away from gasoline tank and lines.
Wipe up any spilled gasoline immediately.
WARNING
Do not use the pump with
fl
ammable or
other hazardous liquids. Failure to follow
this warning may result in explosion, bodily
injury, or death. Read and follow the safety
precautions in the engine owner's manual.
8. Reinstall the pump body with the outlet
fl
ange
facing up. Reinstall the 10 body screws, 10 lock
washers, and 10 nuts to secure the pump body to
the rear bracket. Tighten the cap screws securely
all the way around.
9. The pump is now ready for operation.
Reinstall the 10 body screws and secure
with 10 lock washers and 10 nuts.
OPERATING INSTRUCTIONS
NOTE: The gas engine is shipped without oil
in it. Do not operate the gas engine until it has
been
fi
lled with oil. Consult the engine owner's
manual for oil speci
fi
cations and maintenance
procedures.
NOTE: To avoid premature pump seal failure,
NEVER run the pump dry. Prime and
fi
ll the pump
with the
fl
uid being pumped before starting the
unit.
• Ensure that hose and pipe connections are air
tight. An air leak will reduce pump capacity and
may prevent priming.
• Place the pump and engine on a level foundation,
positioned as close to the liquid tank as possible.
• Keep the suction line short and position it with few
bends.
• Install a pump strainer on the suction line when
pumping dirty water or liquids that contain solids.
CAUTION
Read the engine manufacturer's manual
before operating the Gas Engine Transfer
Pump.