RERUN ARCHITECTURAL

DMX512 RECORDER

MODEL RERUN-A

OWNERS MANUAL

Doug Fleenor Design

396 Corbett Canyon Road
Arroyo Grande, CA 93420

(805) 481-9599

Software Version 1.5
Manual Revision 1.1

$

 Serial #

109001

Содержание RERUN-A

Страница 1: ...RERUN ARCHITECTURAL DMX512 RECORDER MODEL RERUN A OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Software Version 1 5 Manual Revision 1 1 Serial 109001...

Страница 2: ...can be supplied from a variety of sources including a 10V class 2 doorbell transformer The Rerun Architectural system can work in conjunction with a lighting console automatically switching between re...

Страница 3: ...ut Circuit ESD protected EIA 485 transceiver LT1785 Output Circuit ESD protected EIA 485 transceiver LT1785 Isolation None DMX input is not isolated from DMX output Indicators Ten green SHOW LEDs One...

Страница 4: ...ved nomenclature Size Faceplate 4 5 h X 4 6 w X 0 2 d Faceplate rear inset 4 15 h X 4 25 w X 0 1 d Electrical box minimum inside dimensions 2 9 h X 3 5 w X 1 5 d POWER SUPPLY The voltage provided to t...

Страница 5: ...OUT C Dimmer Cabinet Common W hite Blue PW R DMX OUT Data Blue W hite PW R DMX OUT Data OPTIONAL REMOTE PANEL CABLE COLOR FROM TO USE 1 120 Ohm Data Cable Belden 9829 or Equivalent Shield XLR Plate P...

Страница 6: ...oming DMX512 signals will override the Rerun Architectural levels and all shows will be locked out When removed incoming levels will be combined with those of the active show on the Rerun Architectura...

Страница 7: ...OFF SHOW AT END POINT AND LOOPED TO START POINT OFF OFF OFF OFF OFF ON RECEIVING DMX512 THE RERUN A IS LOCKED OUT FROM RUNNING SHOW S AND IS PASSING CONSOLE DATA TO THE OUTPUT ALL FLASH OFF OFF OFF O...

Страница 8: ...the Rerun Architectural must be connected to a DMX512 source It is recommended that your console output all 512 slots When fewer than 512 slots are received a level of 0 will be stored for all slots...

Страница 9: ...d DMX512 from a console will not pass through if the Rerun Architectural is not powered Pausing a show A running show can be paused by pressing the PAUSE button When a show is paused the PAUSE LED wil...

Страница 10: ...ress the REWIND button After it is pressed the START LED will turn on indicating that this point in the show is the start Note The START POINT is set to the top of the show when that show is first rec...

Страница 11: ...ng selections made previously Linking This feature is for advanced users only Linking is similar to show looping However with linking when a show reaches its end instead of looping to re start itself...

Страница 12: ...efault a show stops at its END POINT and the Rerun Architectural continues to send the last levels of that show until a new show is selected Each show can be set up to stop sending DMX512 data entirel...

Страница 13: ...rom any show there is only one record lockout state By default the hardware lockout jumper is installed recording enabled and the software record lockout feature is disabled recording enabled The hard...

Страница 14: ...hen enabled the grand master feature does not alter the levels of the incoming DMX512 levels WARRANTY Products manufactured by Doug Fleenor Design carry a five year parts and labor warranty against ma...