Cross fading

Each show can have the cross fade function enabled or disabled.  When enabled (the default state), the
show will execute a two second fade from the current levels to the levels at the START POINT of the show
when that show is selected.  When cross fading is disabled for a show, the levels will jump immediately
from the current levels to the levels at the START POINT of the show.

To enable or disable cross fading, do the following:
1.

Start playing the show to be edited.

2.

Pause the show at any point.

3.

Press and hold the number 10 [SHOW] button.  Hold the number 10 [SHOW] button for about
five seconds.  While held, the remaining [SHOW LEDS] will indicate the status of other show
and system parameters. The number 3 [SHOW LED] indicates the status of the cross fade
option for that show.  While continuing to hold the number 10 [SHOW] button, press the
number 3 [SHOW] button to toggle the state of the option.  When the number 3 [SHOW LED] is
lit, the cross fade option is enabled.  Set the cross fading option as desired.

4.

Release the number 10 [SHOW] button.

5.

Press the [PAUSE] button to save the new settings and to resume the show.  The next time the
show is selected, it will start using the cross fade option as just recorded.

End of show output

When a show is set to stop running at the END POINT (not looping) the behavior of the 

Rerun Architectural

can be set up in two different ways.  By default, a show stops at its END POINT and the

 Rerun

Architectural 

continues to send the last levels of that show until a new show is selected.  Each show can

be set up to stop sending DMX512 data entirely at the end of the show.  By going off-line, many moving
lights and dimming systems will detect the loss of DMX512 and begin their shut down routines.

To alter the end-of-show behavior, do the following:
1.

Start playing the show to be edited.

2.

Pause the show at any point.

3.

If it is not disabled already, disable looping for the show (Looping section above).

4.

Press and hold the number 10 [SHOW] button.  Hold the number 10 [SHOW] button for about five
seconds.  While held, the remaining [SHOW LEDS] will indicate the status of other show and
system parameters. The number 2 [SHOW LED] indicates the status of the end-of-show output
option for that show.  While continuing to hold the number 10 [SHOW] button, press the number
2 [SHOW] button to toggle the state of the option.  When the number 2 [SHOW LED] is lit, the

Rerun Architectural

 will stop DMX512 output at the end of the show.  When the number 2 [SHOW

LED] is off, the 

Rerun Architectural 

will continue sending DMX512 at the end of the show.  Set the

end-of-show transmission option as desired.

5.

Release the number 10 [SHOW] button.

6.

Press the [PAUSE] button to save the new settings and to resume the show.

 

Note: 

!

The end-of-show behavior will only apply if the show has looping disabled.

!

If the pile-on feature is enabled, the DMX512 output will remain active if there is an input signal present.  In this case,
the output will remain active even if the completed show is set to disable the DMX512 output.

Содержание RERUN-A

Страница 1: ...RERUN ARCHITECTURAL DMX512 RECORDER MODEL RERUN A OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Software Version 1 5 Manual Revision 1 1 Serial 109001...

Страница 2: ...can be supplied from a variety of sources including a 10V class 2 doorbell transformer The Rerun Architectural system can work in conjunction with a lighting console automatically switching between re...

Страница 3: ...ut Circuit ESD protected EIA 485 transceiver LT1785 Output Circuit ESD protected EIA 485 transceiver LT1785 Isolation None DMX input is not isolated from DMX output Indicators Ten green SHOW LEDs One...

Страница 4: ...ved nomenclature Size Faceplate 4 5 h X 4 6 w X 0 2 d Faceplate rear inset 4 15 h X 4 25 w X 0 1 d Electrical box minimum inside dimensions 2 9 h X 3 5 w X 1 5 d POWER SUPPLY The voltage provided to t...

Страница 5: ...OUT C Dimmer Cabinet Common W hite Blue PW R DMX OUT Data Blue W hite PW R DMX OUT Data OPTIONAL REMOTE PANEL CABLE COLOR FROM TO USE 1 120 Ohm Data Cable Belden 9829 or Equivalent Shield XLR Plate P...

Страница 6: ...oming DMX512 signals will override the Rerun Architectural levels and all shows will be locked out When removed incoming levels will be combined with those of the active show on the Rerun Architectura...

Страница 7: ...OFF SHOW AT END POINT AND LOOPED TO START POINT OFF OFF OFF OFF OFF ON RECEIVING DMX512 THE RERUN A IS LOCKED OUT FROM RUNNING SHOW S AND IS PASSING CONSOLE DATA TO THE OUTPUT ALL FLASH OFF OFF OFF O...

Страница 8: ...the Rerun Architectural must be connected to a DMX512 source It is recommended that your console output all 512 slots When fewer than 512 slots are received a level of 0 will be stored for all slots...

Страница 9: ...d DMX512 from a console will not pass through if the Rerun Architectural is not powered Pausing a show A running show can be paused by pressing the PAUSE button When a show is paused the PAUSE LED wil...

Страница 10: ...ress the REWIND button After it is pressed the START LED will turn on indicating that this point in the show is the start Note The START POINT is set to the top of the show when that show is first rec...

Страница 11: ...ng selections made previously Linking This feature is for advanced users only Linking is similar to show looping However with linking when a show reaches its end instead of looping to re start itself...

Страница 12: ...efault a show stops at its END POINT and the Rerun Architectural continues to send the last levels of that show until a new show is selected Each show can be set up to stop sending DMX512 data entirel...

Страница 13: ...rom any show there is only one record lockout state By default the hardware lockout jumper is installed recording enabled and the software record lockout feature is disabled recording enabled The hard...

Страница 14: ...hen enabled the grand master feature does not alter the levels of the incoming DMX512 levels WARRANTY Products manufactured by Doug Fleenor Design carry a five year parts and labor warranty against ma...

Отзывы: