background image

 

Page 4 of 7 

 

 

IMPORTANT NOTE:  DO NOT APPLY 120VAC POWER TO THE PRESET 8.  THE STATION WILL 
BE DAMAGED BEYOND REPAIR AND WILL NOT BE COVERED BY ANY WARRANTY.

 

 

Jumper settings 

There are six jumpers on the rear of the Preset 8.  All are installed at the factory.  This configures the 
Preset 8 as a Main station which will support most applications.  To enable additional features, 
jumpers can be removed as shown by the table below. 
 

Jumper 

Function when installed 

Function when removed 

Record lockout disabled 

Record lockout enabled 

Main station 

 

Remote station 

Hold last DMX input disabled 

Hold last DMX input enabled 

Single station mode 

Multi-station mode (remote station support) 

Station controls locked while DMX present 

DMX piles onto station levels 

Not assigned 

Not assigned 

 

Mounting

 

The Preset 8 can be mounted in most 3-gang electrical boxes.  Raco model 692 box is included with 
each station.  Other boxes may be used provided they have a depth of at least 2 inches. 
 
The Preset 8 must be mounted with the hidden record switch/signal indicator hole to the right.  If the 
Preset 8 is mounted upside down, the sliders will work in reverse.  

Observe the “UP” marking on the 

rear of the Preset 8 for additional verification. 
 

 

 
Configuring Remote stations 

There must be one (and only one) Main station.  The Main station can support up to four Remote 
stations.  If there is only one Remote station, no configuration other than proper jumper setting is 
required.  However, if there are two or more Remote stations, they must be configured to insure 
reliable communications with the Main station.  This following process is used to set each Remote 
station’s unit ID. 
 

Содержание PRESET 8

Страница 1: ...Page 1 of 7 Model PRESET 8 Installation and Operations Manual Doug Fleenor Design Inc 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Voice and FAX Manual revision May 2019...

Страница 2: ...f the levels Environmental Operating temperature 0 40 C 32 104 F Operating humidity 10 90 non condensing Indoor use only Electrical ratings Input 12 24 volts AC or DC 100 mA maximum A common doorbell...

Страница 3: ...roper polarity may result in a damaged transformer which will not be covered by any warranty IMPORTANT NOTE DO NOT APPLY 120VAC POWER TO THE PRESET 8 THE STATION WILL BE DAMAGED BEYOND REPAIR AND WILL...

Страница 4: ...MX piles onto station levels 6 Not assigned Not assigned Mounting The Preset 8 can be mounted in most 3 gang electrical boxes Raco model 692 box is included with each station Other boxes may be used p...

Страница 5: ...from a combination of the two RECORDING CAN ONLY BE PERFORMED ON THE MAIN STATION Preset recording can not be done from a Remote station To record a preset onto a slider perform the following steps U...

Страница 6: ...lashing or flickering In such situations the manufacturer of the non compliant should address the problem If they are unable or unwilling to do so Doug Fleenor Design offers the DMX DECELERATOR This d...

Страница 7: ...ing If a trip is necessary to the customer s site to solve a problem the expenses of the trip must be paid by the customer This warranty covers manufacturing defects It does not cover damage due to ab...

Отзывы: