background image

 

Page 3 of 7

 

 

General notes: 
Preset 8 stations must be connected to one another on 

the input or “upstream” side of DMX splitters 

or processing devices.  

All DMX cabling must be installed in a “daisy chain” or “touch-and-go” wiring 

fashion.  DMX cabling using “star”, “T”, or “Y” configurations will result in unreliable operation. 
 
Station power cabling may be wired using any topology that is convenient.  However, it is usually 
most convenient to run the low voltage power cabling along with the DMX cabling. 
 
Doug Fleenor Design recommends against using the “spare” pair of wire in many DMX cables to 
carry power to the Preset 8 stations.  The wire gauge is inadequate to prevent excessive voltage 
drop.  Unreliable operation may result from this practice. 
 
Main station wiring: 
The DMX signal from a control console must be connected to the three pin DMX IN terminal block 
(TB2). 
 
The DMX output signal from the Preset 8 is available on the five pin terminal block (TB1).  The 
common, data plus, and data minus signals  
 
Input power to the station should also be connected to this terminal block.  The POWER COMMON 
and 12-24V AC/DC terminals are used for power input to the Preset 8 stations.  Take care to observe 
proper polarity when connecting DC power to the Preset 8.  A low voltage AC source can be used to 
power the Preset 8.  The low voltage AC power must be within the range of 12 

– 24V.  Note that if a 

single transformer is used to power multiple stations, all stations must be wired with the same 
polarity.  It does not matter which wire from the transformer is connected to the C terminal, but the 
same wire must be connected at all stations.  Failure to observe proper polarity may result in a 
damaged transformer which will not be covered by any warranty. 
 

IMPORTANT NOTE:  DO NOT APPLY 120VAC POWER TO THE PRESET 8.  THE STATION WILL 
BE DAMAGED BEYOND REPAIR AND WILL NOT BE COVERED BY ANY WARRANTY.

 

 
Remote station wiring: 
All DMX cabling to and from a Preset 8 Remote station must be connected to the five pin terminal 
block (TB1).  The cable from the prior station and the cable going out to the next station (or other 
DMX devices) will be connected to the same terminals on the five pin terminal block (TB1).  The three 
pin terminal block (TB2) is not used by Remote stations.  

No cables are to be connected to the 

three pin terminal block (TB2) if the station is configured as a Remote station. 
 

Remote stations may be connected to the Main station input or output connectors.  The Main station 
supports Remote stations on both its input and output ports simultaneously.  However, only a total of 
four Remote stations are supported.  Each Remote station must have its own unique ID (described 
later in this document) regardless of which Main station port it is connected to. 
 
Input power to the station must be connected to the five pin terminal block.  The POWER COMMON 
and 12-24V AC/DC terminals are used for power input to the Preset 8 stations.  Take care to observe 
proper polarity when connecting DC power to the Preset 8.  A low voltage AC source can be used to 
power the Preset 8.  The low voltage AC power must be within the range of 12 

– 24V.  Note that if a 

single transformer is used to power multiple stations, all stations must be wired with the same 
polarity.  It does not matter which wire from the transformer is connected to the C terminal, but the 
same wire must be connected at all stations.  Failure to observe proper polarity may result in a 
damaged transformer which will not be covered by any warranty. 

Содержание PRESET 8

Страница 1: ...Page 1 of 7 Model PRESET 8 Installation and Operations Manual Doug Fleenor Design Inc 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Voice and FAX Manual revision May 2019...

Страница 2: ...f the levels Environmental Operating temperature 0 40 C 32 104 F Operating humidity 10 90 non condensing Indoor use only Electrical ratings Input 12 24 volts AC or DC 100 mA maximum A common doorbell...

Страница 3: ...roper polarity may result in a damaged transformer which will not be covered by any warranty IMPORTANT NOTE DO NOT APPLY 120VAC POWER TO THE PRESET 8 THE STATION WILL BE DAMAGED BEYOND REPAIR AND WILL...

Страница 4: ...MX piles onto station levels 6 Not assigned Not assigned Mounting The Preset 8 can be mounted in most 3 gang electrical boxes Raco model 692 box is included with each station Other boxes may be used p...

Страница 5: ...from a combination of the two RECORDING CAN ONLY BE PERFORMED ON THE MAIN STATION Preset recording can not be done from a Remote station To record a preset onto a slider perform the following steps U...

Страница 6: ...lashing or flickering In such situations the manufacturer of the non compliant should address the problem If they are unable or unwilling to do so Doug Fleenor Design offers the DMX DECELERATOR This d...

Страница 7: ...ing If a trip is necessary to the customer s site to solve a problem the expenses of the trip must be paid by the customer This warranty covers manufacturing defects It does not cover damage due to ab...

Отзывы: