11
Pole Mounting S-Type with Strong-Arm
Pre-Install EZ-Lock Pole Mount #BR-MPM1 (sold separately) by following Instructions detailed in Installation Guide provided with pole
mount bracket. Pole Mount requires user supplied stainless steel strapping to secure Pole Mount Bracket to the pole, strapping into
final desired position. Locate four (4) 5/16”-18 x 1.5” Hex bolts & washers provided with EZ-Lock, and securely fasten base of S-Type
Strong-Arm to Bracket.
Attach housing to arm as shown, tighten screws evenly but firmly on both sides of housing. Adjust housing to desired position using
both pan & tilt adjustment fasteners and tighten all bolts evenly & securely, so housing is pointing into final position.
Firmly tighten wire feed nuts to create water tight seal around cabling. Only a single round cable bundle should be inserted per seal port
for an effective seal.
For Installations using Liquid-Tight conduit,
please refer to Conduit Guidelines
provided near front of this manual.
Note:
A
ll internal wire feeds
must be fully sealed at enclosure to provide satisfactory product performance, and a safe & moisture free
installation.
Firmly tighten four (4) stainless steel Phillips screws on top of S-type lid to secure & seal enclosure to complete installation. Do not over-
tighten.
Wiring Notes:
Always consult and follow all local and applicable electrical codes to install and service housing. Always shut off power
before installation and follow all applicable safety practices and guidelines. Only qualified electrical technicians should prepare &
service wiring. Fully read & understand all installation guidelines before attempting to install wiring & housing.
Site wiring can be installed behind, or installed to side of base of the S-Type Strong-Arm. Main body of this Arm has room for
flush electric box, or cable feed thru wall to be mounted behind mounting base. Prepare wiring before installation of this housing
mount, allowing strong backing material to secure Strong-Arm mount. Hole on side of mount arm and on bottom of S-Type housing
are clearance holes that will accept ½” NPT fittings or PG13 equivalent.
Wire feed can be directly into hollow of Arm, with room for wire management within Arm body. Hole on side of mount arm,
and feeds on bottom of S-Type housing are clearance holes that will accept ½” NPT fittings or PG13 equivalent. A plug is provided with
Arm hardware if this feed hole is not used. Some customers will choose to provide & use liquid tight fittings & conduit to make the
connection arm feed and S-Type enclosure.
Always create a drip loop between all external conduit or cable connections between fittings and S-Type Housing. All cable
feeds must be sealed before S-Type housing is put into service to provide dry, electrically safe, and effective product performance.