AssuredSAN 4004 Series FRU Installation and Replacement Guide
15
Supported drive enclosures
1
These 4004 Series-compatible expansion enclosure models feature 6 Gbit/s internal disk and SAS expander link speeds.
2
See the AssuredSAN Ultra48 Series Setup and FRU I&R Guides for information about the high-capacity 2U48 chassis form factor.
3
See the AssuredSAN Ultra56 Series Setup and FRU I&R Guides for information about the high-capacity 4U56 chassis form factor.
4
See the 4004 Series Setup Guide for maximum enclosure limits and associated cabling configurations.
5
The 4004 Series and Ultra56 Series—which includes the J6G56—are designed for NEBS compliance, but the 3004 Series and
Ultra48 Series—which includes the J6G48—are
not
.
6
Reference documents for the J6G48 (2U48) and J6G56 (4U56) are listed below.
7
See
http://www.dothill.com
for most current information concerning support of drive enclosures for storage expansion.
Within the AssuredSAN 4004 Series product line, the 2U12 and 2U24 chassis can be configured as
either a controller enclosure or a drive enclosure for adding storage. These enclosures look very similar to
one another. For a given from factor (2U12 or 2U24) only the IOM geometry differs: either it is a controller
module or an expansion module. The remaining FRUs for a given chassis are common.
Within the AssuredSAN 4004 Series product line, the high-capacity 2U48 chassis is supported as an
expansion enclosure (J6G48) for adding storage to 2U12 or 2U24 controller enclosures.
IMPORTANT:
For illustrations and information about the 2U48 chassis—which is supported as a drive
enclosure option for 4004 Series controller enclosures—refer to the following related documents:
•
AssuredSAN Ultra48 Series Setup Guide
•
AssuredSAN Ultra48 Series FRU Installation and Replacement Guide
•
AssuredSAN Ultra48 Rackmount Bracket Kit Installation
Within the AssuredSAN 4004 Series product line, the high-capacity 4U56 chassis is supported as an
expansion enclosure (J6G56) for adding storage to 2U12 or 2U24 controller enclosures.
IMPORTANT:
For illustrations and information about the 4U56 chassis—which is supported as a drive
enclosure option for 4004 Series controller enclosures—refer to the following related documents:
•
AssuredSAN Ultra56 Series Setup Guide
•
AssuredSAN Ultra56 Series FRU Installation and Replacement Guide
•
AssuredSAN Ultra56 Rackmount Bracket Kit Installation
•
AssuredSAN Ultra56 Enclosure Bezel Kit Installation
Table 5
Compatible drive enclosure options for adding storage
Model
Form
Enclosure description
Disk drives Rear panel connection
NEBS
J6G24
2U24
24-drive 6 Gbit/s chassis with FRUs
2.5" (SFF) mini-SAS to mini-SAS
Note 5
J6G12
2U12
12-drive 6 Gbit/s chassis with FRUs
3.5" (LFF) mini-SAS to mini-SAS
Note 5
J6G48
2U48
48-drive 6 Gbit/s chassis with FRUs
2.5" (SFF) mini-SAS to mini-SAS
Note 5
J6G56
4U56
56-drive 6 Gbit/s chassis with FRUs
3.5" (LFF) mini-SAS to mini-SAS