©
DOSATRON INTERNATIONAL /
29
EN
THE MANUFACTURER DECLINES ALL RESPONSIBILITY IF
THE DOSATRON IS USED IN CONDITIONS THAT DO NOT
CORRESPOND TO THE OPERATING INSTRUCTIONS AS
INDICATED IN THIS MANUAL
SYMPTOM
CAUSE
SOLUTION
Injection
Under injection.
Suction of air.
1. Check the tightness
of the nuts in the
injection area.
2. Check suction tube.
Dirty or worn check
valve seal.
Clean or replace it.
Maximum flow
exceeded (cavitation).
Reduce flow.
Worn plunger seal.
Replace it.
Worn injection stem
Replace it.
Leaks
Leaks in the vicinity
of the fixing ring
under the body
housing.
Injector sleeve
seal is damaged or
positioned incorrectly.
Replace it.
Leaks between the
setting sleeve and
the locking ring.
Injector stem seal
damaged, positioned
incorrectly or missing.
Replace it.
Leaks between the
body and screw-
top.
Screw-top seal is
damaged, positioned
incorrectly or missing.
Unscrew the screw-top,
clean the seal seating,
replace or change the seal.
Position correctly the
screw-top.
Regulator DOSATRON
Leak
Faulty sealing
Return the Dosatron unit
to your service center for
repair
EC PROBE
Please refer to the EC PROBE section
Содержание D30 GL 02
Страница 1: ...D30 GL 02 D30 GL 02 EC D30 GL 1 D30 GL 1 EC 30 m3 h 132 GPM owner s manual...
Страница 5: ...DOSATRON INTERNATIONAL 4 DOSATRON INTERNATIONAL 4 NOTES...
Страница 33: ...DOSATRON INTERNATIONAL 33 Annexes Enclosure Anhang Anejos Allegati Bijvoegsel D F QLNL Anexos...
Страница 34: ...DOSATRON INTERNATIONAL 34 DOSATRON INTERNATIONAL 34 Courbes Curves Diagramm Curva XUYDV UDILHN U ZH Gr ficos 35...