Page 1
800-523-8499
www.dosatronusa.com
Proper protection, such as gloves, eye wear, and aprons, are recommended when disassembling a Dosatron.
Step 3:
Check to see if you feel suction on your finger.
Step 2:
If there is still no suction, but the Dosatron unit is clicking,
turn the water on. Unscrew and remove the suction hose nut or
clamp and hose.
D14MZ10 Troubleshooting - Part 1
This D14MZ10 - 14 GPM Troubleshooting - Part 1 will cover: The Injector is
not drawing the concentrate, but is
clicking.
Scan the QR code to
watch our D14MZ10 -
Troubleshooting video.
Step 1:
Take a look at the strainer. If it is clogged just clean it out
and retest your Dosatron unit.
NOTE:
To service your D14MZ10 you will need a strap wrench
(Part #: TOOL01) and a small flat head screw driver.