11.2
Connections
Hose lengths and cable lengths
Detail
Value
Between control system and
motor, max.
50 m
Between control system and
recirculation controller, max.
50 m
Cable Pressure sensor, max.
200 m
Cable overpressure switch,
max.
200 m
11.3
Operating conditions
Detail
Value
Min. ambient temperature
10 °C
Max. ambient temperature
40 °C
Min. relative humidity
20 %
Relative humidity, max.
80 %
Installation altitude, max.
2000 m (NHN)
Protection type
IP54
11.4
Operating values
Detail
Value
Compressed air, min.
6 bar
Compressed air: max.
8 bar
Flow rate
5 m
3
/h
Voltage, min.
3 x 380 V
Voltage, max.
3 x 500 V
Protection
32 A (C/gG)
Frequency
50 / 60 Hz
Power
Option
Value
Eco
PUC MC-X-0750-XX-X-X-X
2.3 kVA
Eco
PUC MC-X-1500-XX-X-X-X
4.2 kVA
Eco
PUC MC-X-3000-XX-X-X-X
7.3 kVA
Power
Option
Value
Eco
PUC MC-X-0750-XX-X-X-X
3.3 A at
3 x 400 V
Eco
PUC MC-X-1500-XX-X-X-X
6 A at
3 x 400 V
Eco
PUC MC-X-3000-XX-X-X-X
10.5 A at
3 x 400 V
11.5
Compressed air quality
Purity classes ISO 8573-1:2010 1:4:1
Limitations for purity class 4 (pressure dew
point max.):
≤ -3 °C at 7 bar absolute
≤ +1 °C at 9 bar absolute
≤ +3 °C at 11 bar absolute
11.6
Type plate
Fig. 75: Position of type plate
The type plate (1) shows the following details:
Product denomination
Material number
Year of manufacture
Minimum air pressure
Maximum air pressure
Protection type
Voltage
Frequency
Power
Protection
Weight
CE labeling
Manufacturer
QR code
Technical data
05/2017
EcoPUC MC - MCU00003EN
51/68