Fixed and Adjustable Height Stands Set-up, Operation & Maintenance Manual
Dorner Mfg. Corp.
851-558 Rev. A
Ç
Failure to secure screws (M
of Figure 5) may cause
conveyor sections to drop
down causing severe injury.
TIGHTEN SCREWS (M)
AFTER ADJUSTMENT.
5
.
Align two crossmember mounting brackets (B of
Figure 5) with two u
−
nuts (N). Install four M8 flange
socket head screws (M) through brackets and into
u
−
nuts. Tighten screws to 150 in
−
lb (17 N
−
m).
Figure 5
6
.
For leveling and height adjustment see Stand
Installation, Maintenance and Parts Manual.
Attaching Common Mount to Conveyor
NOTE:
When installing three or more conveyors on
common mount, attach the inner conveyor(s) first.
1
.
Slide two t
−
bar drop
−
ins (G of Figure 6) into each
channel in crossmember (A).
Figure 6
2
.
Install socket head screw (H of Figure 7) through
inner hole (Q) in conveyor mounting bracket (K) and
into t
−
bar drop
−
Figure 7
3
.
Repeat step 2 for three remaining drop
−
ins.
4
.
Repeat steps 1 through 3 for other conveyor
mounting bracket(s). Tighten screws (H) to 80 in
−
lb
(9 N
−
m).
5
.
For leveling and height adjustment see Stand
Installation, Maintenance and Parts Manual.
Installation