![Dormakaba TS93 GSR T Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/dormakaba/ts93-gsr-t-series/ts93-gsr-t-series_installation-instructions-manual_2522937009.webp)
dormakaba TS93 GSR/EMF T 1A, 1I, 2 Installation Instructions
08280031
08-2019
TS93 GSR Surface Applied Closers
9
Wiring EMF
2.9 Wiring the EMF
Fig.11
EMF 2
EMF 1I
EMF 1A
2.9.1
Determine appropriate EMF unit and follow steps below:
EMF 2:
Plug in wire harness into terminals 1 and 2 (active
door track) of the 6-pin terminal block.
EMF 1I
: Plug in wire hardness to terminals 1 and 2
(active door track) of the 6-pin terminal block.
EMF 1A
: No plug in wire harness to 6-pin terminal block
of active door.
NOTE: Be sure power is off prior to making following connections:
2.9.2
Connect power wire harness to 24 VDC power supply.
2.9.3
Plug in power wire harness to terminals 5 and 6 (active
door track) of 6-pin terminal block.