background image

dormakaba TS93 GSR/EMF T 1A, 1I, 2 Installation Instructions

08280031

08-2019

TS93 GSR Surface Applied Closers

3

Technical specifications

1   Technical specifications

1.1 Overview

Door Width

Closer

Interior/ 

Exterior

1'-3" 

min.

2’-6" 

max.

3’-0” 

max.

3’-6” 

max.

4’-0” 

max.

4’-6” 

max.

5’-0” 

max.

TS9315

Interior

NA

NA

TS9356

Interior

NA

NA

NA

NA

Caution: sex nuts are required for attachment of 
components to unreinforced doors and to wood or plastic 
faced composite type fire doors, unless an alternative 
method is identified in the individual door    manufacturer’s 
listings.

Maximum door opening degree is 175°.

Minimum door width is 15”.

Hold open range is from 80° to 130° with optional hold 
open kit.

Arrows on closer mounting plate point upward.

A carry bar should be installed to insure that the active 
door is opened enough for the inactive door to close.  
Recommended carry bars: 
DORMA carry bar MK-397 (up to 3’-6” wide door)DORMA 
carry bar MK-398 (3’-6” and wider door) 
Installation instructions are included with carry bar.

Follow included template to properly prepare door and 
frame for all accessories of the closer installation.

Know the swing of the door which is being installed prior to 
installation.

Make sure door efficiently operates prior to installing 
closer.

Verify closer spring size prior to installation. 

Table 1

Table 2

Drill bits:

Pozidriv PZ-2

M5 hex key

Metal:   No. 21 & 10-32 tap

#2 Phillips screwdriver

M2 hex key

Wood:   1/8”

3/16” flat head screwdriver

1.2  Size selection chart

1.3  Tools recommended

GSR/EMF T 1I 

 

(Active door & inactive door holds open together)

The GSR/EMF T 1I incorporates an electric hold open mechanism in 
the inactive leaf. The coordinator mechanism tied to the inactive 
leaf in turn holds the active leaf at whatever degree of opening it is 
placed. Both doors will close in sequence (inactive first) from any 
point upon signal from the fire alarm system or when electrical 
current is interrupted.

GSR/EMF T 1A (Active door hold open)

The GSR/EMF T 1A incorporates an electrical hold open 
mechanism in the active leaf. This eliminates the need to hold the 
inactive leaf in the open position to initiate hold open of the active 
leaf. This version permits the active leaf to be held open at a 

preselected point when the inactive leaf is in the closed position. 
The door will close from any point upon signal from the fire alarm 
system or when electrical current is interrupted.

GSR/EMF T 2 (Active door hold open only or inactive & 

active hold open together)

The GSR/EMF T 2 incorporates an electric hold open mechanism in 
both door leaves. This enables both leaves to be held open when 
the inactive door is placed in the preselected hold open position 
and also enables the active door to be held open independently 
when the inactive door is in the closed position. Both doors will 
close in sequence (inactive first) from any point upon signal from 
the fire alarm system or when electrical current is interrupted.

Содержание TS93 GSR T Series

Страница 1: ...TS93 GSR EMF T 1A 1I 2 Surface Applied Closer Pull side track mount and coordinator system Installation instructions 08280031 08 2019 EN ...

Страница 2: ...r 4 2 Installation instructions 5 2 1 Installing the back plate 5 2 2 Installing the surface closer 5 2 3 Installing the slide channel 6 2 4 Installing the main arm 6 2 5 Secure main arm 7 2 6 Installing the coordinator system 7 2 7 Installing conduit for EMF 8 2 8 Installing coordinator system continued 8 2 9 Wiring the EMF 9 3 Adjustments 10 3 1 Adjust closing speeds sweep latch backcheck delaye...

Страница 3: ...1 10 32 tap 2 Phillips screwdriver M2 hex key Wood 1 8 3 16 flat head screwdriver 1 2 Size selection chart 1 3 Tools recommended GSR EMF T 1I Active door inactive door holds open together The GSR EMF T 1I incorporates an electric hold open mechanism in the inactive leaf The coordinator mechanism tied to the inactive leaf in turn holds the active leaf at whatever degree of opening it is placed Both...

Страница 4: ... of door Interior side of door Left hand door LH Right hand door RH The surface closer is comprised of the following components 1 Closer body B body 2 Main arm 3 Active track assembly 4 Inactive track assembly 5 Pinion 6 Track covers and center cover 7 Closer cover 8 Closer end caps 9 Connecting channel 1 5 Handing the door Fig 2 1 4 Surface closer system 1 5 7 8 6 3 4 3 4 6 9 2 2 ...

Страница 5: ...ecure closer body to plate Use four M5 x 47mm screws for each closer NOTE Use ONLY hand Phillips bit driver 2 or Pozidriv PZ 2 2 2 Installing the surface closer Fig 4 Fig 3 2 1 1 Secure plate to door Use four 10 32 x 5 8 PH screws 10 x 1 1 2 wood screws provided for each plate NOTE Ensure arrows point in direction of arm location Left hand door Right hand door Backplate 10 32x5 8 Toward the hinge ...

Страница 6: ...s flat head driver 2 3 3 Insert end caps into track 2 3 4 Secure end of track through end caps Use two 10 32x2 FH screws 2 3 5 Slide end cap covers onto end caps 2 3 Installing the slide channel Fig 5 2 4 1 Attach 1 2 wrench to bottom pinion 2 4 2 While looking up rotate pinion square until it aligns to square hole on arm LH turn 5 counter clockwise RH turn 5 clockwise Right hand door Inactive Lef...

Страница 7: ...reely If locking pin falls out discard after completing installation Arm Slide shoe Arm M8x15 SH bolt Left hand door Active Right hand door Inactive Trigger dial 2 6 Installing the coordinator system Fig 8 2 6 1 Close both door leafs 2 6 2 Push plastic guide element up against slide shoe 2 6 3 Fully wind trigger dial towards door frame 2 6 4 Align connecting channel with trigger dial per image abo...

Страница 8: ...rdinator system continued Fig 10 Left hand door Active Right hand door Inactive Clamping rod Trigger dial Connecting channel Set screw Locking pin Plastic guide Connecting channel Clamping plate Trigger dial 2 8 1 Open active leaf to retract clamping rod 2 8 2 Active door Insert connecting channel into trigger dial 2 8 3 Inactive door Insert connecting channel into plastic guide 2 8 4 Unwind trigg...

Страница 9: ...ss into terminals 1 and 2 active door track of the 6 pin terminal block EMF 1I Plug in wire hardness to terminals 1 and 2 active door track of the 6 pin terminal block EMF 1A No plug in wire harness to 6 pin terminal block of active door NOTE Be sure power is off prior to making following connections 2 9 2 Connect power wire harness to 24 VDC power supply 2 9 3 Plug in power wire harness to termin...

Страница 10: ...ld open force Decrease force spin dial away from door frame Increase force spin dial towards door frame NOTE Do not set release force too high Damage may occur to door hinges or GSR system 3 2 Adjust optional hold open Increase Decrease Decrease Increase Backcheck Delayed action Sweep Latch Speed 3 1 1 Adjust the closing sweep speed for the area from 70 to start of latch Increase sweep speed Turn ...

Страница 11: ... the door TS9356 NOTE Supplied with a size 6 spring setting Increase force turn clockwise 6 times max Regular Mount Pull side closers Closer size Max door weight lbs Door width Full turns Interior Exterior TS9315 2 100 2 6 5 3 125 3 2 6 9 4 150 3 6 3 14 5 200 4 3 6 18 TS9356 5 200 4 3 6 4 6 250 4 6 4 0 4 Install covers 4 1 1 Snap both end covers onto closer body end caps 4 1 2 Remove un needed tab...

Страница 12: ...www dormakaba com dormakaba DORMA USA Inc 1 Dorma Drive Drawer AC Reamstown PA 17567 USA T 717 336 3881 F 717 336 2106 ...

Отзывы: