2

SIO-DR

2019-04

WN 059731 45532

dormakaba Mounting instructions

Mounting

4  Mounting

4.1  Mount the SIO-DR

5.1

J-Y(St)Y 

2x2x0.8

1.

2.

1

2

1.

 

4.2  Assignment of terminals and switches

Out 1

Out 2 Out 3

Out 4

GND 24V

N

O

C

N

C

N

O

C

N

C

N

O

C

N

C

N

O

C

N

C

GND 24V

DCW

In 1

In 2 In 3

In 4

GND 24V

1 A B 3

GND 24V

1 A B 3

Addr

X500

X504

X502

X506

X510

X507

X400

Out 1

Out 2 Out 3

Out 4

GND 24V

N

O

C

N

C

N

O

C

N

C

N

O

C

N

C

N

O

C

N

C

GND 24V

DCW

In 1

In 2 In 3

In 4

GND 24V

1 A B 3

GND 24V

1 A B 3

Addr

X500

X504

X502

X506

X510

X507

X400

Technical information

Supply voltage:

24 V DC +/- 15 %

Power consumption:
- Quiescent current:
- Relay
For each active relay, 
the current consumption 
increases  
by approx. 11 mA

7 mA
Relay 1 active 18 mA
Relay 1+2 active 29 mA
Relay 1+2+3 active 40 mA
Relay 1+2+3+4 active 51 
mA

Ambient temperature:

-10 °C to +55 °C

Rel. humidity:

up to 93 % (non 
condensing)

Protection class:

dependent on the housing 
used

Inputs 
In 1 to In 4
(optocoupler)

Current consumption of 
inputs per input:
at   5 V  AC/DC:  3 mA
at   12 V  AC/DC:  8 mA
at  24 V  AC/DC:  17 mA
at  28 V  AC/DC:  28 mA

Contact load capacity: 24 V, 1 A current carrying 

capacity    

3.2  LED displays

DCW

LED on 

    LED off 

    LED flashes       

Bus connection OK
Power supply or DCW® bus 
connection disturbed

 

 

Bus connection interrupted 
(not Safe DCW® node)

                    

  

Содержание SIO-DR

Страница 1: ...efore touching a component 2 Safety 2 1 Intended use The SIO DR module is used to connect analog switch contacts to the dormakaba system bus Messages are output via contacts or control signals are read in 2 2 Personnel qualification Mounting may only be carried out by persons authorized by dormakaba 3 Product description The SIO DR module is a DCW component Status messages are output potential fre...

Страница 2: ...ormation Supply voltage 24 V DC 15 Power consumption Quiescent current Relay For each active relay the current consumption increases by approx 11 mA 7 mA Relay 1 active 18 mA Relay 1 2 active 29 mA Relay 1 2 3 active 40 mA Relay 1 2 3 4 active 51 mA Ambient temperature 10 C to 55 C Rel humidity up to 93 non condensing Protection class dependent on the housing used Inputs In 1 to In 4 optocoupler C...

Страница 3: ... 4 are assigned to the corresponding door addresses 1 to 4 X504 Out 3 Out 4 Contact load capacity 24 V 1 A Contact load capacity 24 V 1 A Emergency button pressed Locked X506 In 1 In 2 Optocoupler 5 28 V AC DC Optocoupler 5 28 V AC DC Temporary unlocking Ü1 Long term unlocking Ü1 Parameterizable via TMS Soft In multi door systems In 1 to In 4 are assigned to the corresponding door addresses 1 to 4...

Страница 4: ...osal Disassembly is carried out in the reverse order of mounting and must be carried out by qualified personnel The product must be disposed of in an environmentally friendly manner Electro technical parts and batteries must not be disposed of as domestic waste Dispose of electrotechnical parts and batteries in the designated acceptance and collection points Refer to the statutory regulations for ...

Отзывы: