background image

Saflok Quantum Pixel 

PK3693_T 

02-19 

3

Figure 1 - Exploded Lock View  

Controller face plate

#8-32 X 1/4 Flat Head Screws

#6 X 1/2 Flat Head Screws

#6 X 1/2 Flat 

Head Screws

Reader Cover

Reader Base

Lock Controller

#12 X 1 Pan 

Head Screws

#4 X 3/16 Screw

Antenna PCB

Thumb Turn Base

Thumb Turn

Strike Plate

I/S Lever Rose

I/S Lever Assy

O/S Lever Assy

#12 X 1-1/2

OR

#12-24X 3/8 

Flat Head Screws

#8-32 X 1/4 Flat Head Screws

Mortise Face Plate

Mortise

#12 X 1-1/4 Flat Head Screws

#8-32 Shoulder Screws

Figure 2 - Door preperation jig

Door and door frame preparation

Содержание Saflok Quantum Pixel

Страница 1: ...Saflok Quantum Pixel Installation Instructions PK3693 T 2019 02 EN ...

Страница 2: ... intended for the sole use of the addressee s so named Any misuse of this confidential information contained herein may result in legal action by dormakaba USA Inc and its parent company Door and door frame preparation Tools required for this step Recommend doors prepped at factory for higher precision Do not drill both STD and ADB Ø7 16 thumb turn holes Drill only the hole that corresponds to the...

Страница 3: ...over Reader Base Lock Controller 12 X 1 Pan Head Screws 4 X 3 16 Screw Antenna PCB Thumb Turn Base Thumb Turn Strike Plate I S Lever Rose I S Lever Assy O S Lever Assy 12 X 1 1 2 OR 12 24X 3 8 Flat Head Screws 8 32 X 1 4 Flat Head Screws Mortise Face Plate Mortise 12 X 1 1 4 Flat Head Screws 8 32 Shoulder Screws Figure 2 Door preperation jig Door and door frame preparation ...

Страница 4: ...tion templates NOT TO SCALE PAGE 1 O S TRIM LOWER MORTISE PAGE 2 I S TRIM PAGE 3 UPPER CONTROLLER MORTISE PAGE 4 STRIKE PREP OUTSIDE PREP INSIDE PREP x x LOWER MORTISE CENTERED IN DOOR UPPER MORTISE OFFSET TO O S DOOR FACE IF GREATER THAN 1 3 4 DOOR THICKNESS CENTERED FOR 1 3 8 TO 1 3 4 DOOR THICKNESS ...

Страница 5: ...0 1 Lower Mortise Installation a Pre Drill 12 screw pilot holes b Slide mortise into lower pocket c Route mortise cable harness along the side wire channel that connectsthe top and bottom mortise pockets see figure 6 for wire channel location d Secure with included 12 flat head screws e Ensure wire harness is free and not pinched Figure 5 Lock Exploded View with Mounted Controller and Mortise Figu...

Страница 6: ... c Slide tray out partially from controller to ensure tabs are not bent when securing 12 screws d Lift and center assembly to ensure proper alignment e Secure with included 12 pan head screws f Slide the tray out partway to and ensure all connections are secure Do not connect the battery at this point g Connect the harnesses from the mortise and controller together Do not seat the slide tray in do...

Страница 7: ...roller case is not drilled into and damaged Don t apply too much pressure when drilling to help maintain door integrity f Secure the reader base to the outside of the door using the included 6 flat head screws Don t apply too much torque but ensure base is fully seated against door g Plug the antenna into the 6 pin socket visible through the hole in the door Figure 9 Reader Base i Align pins in up...

Страница 8: ...ews 5 Lever Set Installation If supplied by dormakaba a Place the outside lever rose assembly on the outside of the door b Place the inside lever rose assembly on the inside of the door c Secure to the outside rose assembly using the included shoulder screws d Carefully slide the escutcheon over the lever and ensure removal notch is aligned below lever set for concealment ...

Страница 9: ... the door with the included screws e Align turn piece onto base so that it is at 12 and 6 o clock see figure 12 Figure 12 Thumb Turn Base Alignment Mortise Cam f Install the turn piece onto the base by screwing the collar on clockwise until tight torque secure with spanner wrench g Check the turn for smooth operation ensuring no drag or binding occurs If binding occurs verify base alignment with m...

Страница 10: ... lock to desired room number see figure 13 for USB programming port Figure 13 USB Programming Cable Connection 3 Reader Cover Installation a Locate release hole at 5 00 see figure 14 b Place the lens onto the base and rotate clockwise to secure at 6 00 c Ensure cover is secured locking tab will click when fully seated For ease of assembly and disassembly wrap thumb around circumference of cover to...

Страница 11: ...ate not set use the Quantum LPI probe to reset Yellow LED flashes 12 times Dead bolt is thrown or switch cam is not properly aligned Yellow LED flashes 2 times Keycard not allowed OR keycard cancelled by new keycard Red and green LEDs flash alternately 9 times Low battery contact the SAFLOK service department Yellow and red LEDs flash 2 times simultaneously Bad keycard read or corrupted data may r...

Страница 12: ...t is made with the strike plate door closed Electronics Keycards Present keycard in front of reader and the yellow light flashes twice when incorrect keycard is used Green light flashes when the proper keycard is used Green light is flashing when the lever is operated Green light continues to flash for a five second cycle Yellow light flashes 12 times when the dead bolt is extended and a guest hot...

Страница 13: ...to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Industry Canada licence exempt RS...

Страница 14: ...a com dormakaba USA Inc Customer Services Support Saflok 1 800 999 6213 1 248 837 3700 General information dormakaba us Online consumable orders www saflokstore com To access all of our easy steps please visit our support website www dormakabalodgingsupport com ...

Отзывы: